Chromatographic method for estimation of vitamin E from dried blood spot sample

被引:0
|
作者
Navale, Archana Mohit [1 ]
Patel, Vichika R. [2 ]
Tandel, Falguni B. [2 ]
机构
[1] Parul Inst Pharm, Dept Pharmacol, Vadodara, Gujarat, India
[2] Parul Inst Pharm, Dept Qual Assurance, Vadodara, Gujarat, India
关键词
Vitamin E; RP-HPLC; Dry blood spot (DBS); Alpha tocopheryl acetate; ALPHA-TOCOPHEROL; PLASMA; DISEASE;
D O I
10.1186/s43094-020-00025-1
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: We developed a selective bioanalytical RP-HPLC method for estimation of vitamin E from dried blood spot (DBS) sample, a potential technique which can be used for population-based epidemiological studies. Vitamin E was extracted from DBS by using liquid-liquid extraction technique with methanol (100% v/v) as reconstituting solvent for the residue. Alpha tocopheryl acetate was used as internal standard. Samples were analyzed directly on HPLC with C-18 (250 x 4.6 mm x 5 mu m) Phenomenex column. The mobile phase used was methanol to water (99:1% v/v) at a flow rate of 1.4 mL/min. The detector wavelength used was 292 nm. Results: The retention time observed for vitamin E and internal standard was 10.225 +/- 0.00075 min and 13.580 +/- 0.00075 min respectively. The vitamin E calibration curve was found to be linear over the range of 0.625 to 60 mu g/mL. The limit of quantification for vitamin E was found to be 0.1 mu g/mL. Accuracy of the developed method was found to be 103.179%, 101.625%, and 100.174% with percentage of coefficient of variation of 0.0161, 0.0215, and 0.2790 for HQC, MQC, and LQC samples respectively which were within USFDA acceptance limit of +/- 15 to +/- 20%.The intraday and interday precision expressed as coefficient of variation were 0.0191-0.0841% and 0.0074-0.0252% respectively. Conclusions: The method represents a simple, rapid, specific, accurate, and precise method for estimation of vitamin E in human blood using DBS technique. The developed method can be further evaluated with respect to effect of matrix variability before it can be used in clinical setting.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A dried blood spot method to evaluate cholinesterase activity in young children
    Hilborn, ED
    Padilla, S
    ARCHIVES OF ENVIRONMENTAL HEALTH, 2004, 59 (09): : 467 - 470
  • [42] Investigations into the environmental conditions experienced during ambient sample transport: impact to dried blood spot sample shipments
    Bowen, Chester L.
    Dopson, Wesley
    Kemp, Daniel C.
    Lewis, Mark
    Lad, Rakesh
    Overvold, Carol
    BIOANALYSIS, 2011, 3 (14) : 1625 - 1633
  • [43] Development of Flow Injection Analysis Method for the Second-Tier Estimation of Succinylacetone in Dried Blood Spot of Newborn Screening
    Bijo Varughese
    Dnyanoba Madrewar
    Sunil Kumar Polipalli
    Seema Kapoor
    Indian Journal of Clinical Biochemistry, 2022, 37 : 40 - 50
  • [44] Development of Flow Injection Analysis Method for the Second-Tier Estimation of Succinylacetone in Dried Blood Spot of Newborn Screening
    Varughese, Bijo
    Madrewar, Dnyanoba
    Polipalli, Sunil Kumar
    Kapoor, Seema
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2022, 37 (01) : 40 - 50
  • [45] Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples
    Skogstrand, Kristin
    Ekelund, Charlotte K.
    Thorsen, Poul
    Vogel, Ida
    Jacobsson, Bo
    Norgaard-Pedersen, Bent
    Hougaard, David M.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 336 (01) : 78 - 84
  • [46] Correction to: Precise, accurate and user-independent blood collection system for dried blood spot sample preparation
    Ricardo Neto
    Andrew Gooley
    Michael C. Breadmore
    Emily F. Hilder
    Florian Lapierre
    Analytical and Bioanalytical Chemistry, 2018, 410 : 4235 - 4235
  • [47] Perforated dried blood spot accurate microsampling: the concept and its applications in toxicokinetic sample collection
    Li, Fumin
    Ploch, Stephen
    Fast, Douglas
    Michael, Steve
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (05): : 655 - 667
  • [48] Estimation of genetic risk for Type 1 diabetes mellitus in newborns on dried blood spot
    Giannattasio, A.
    Caruso, U.
    Napoli, F.
    Salina, A.
    Aloi, C.
    Lorini, R.
    d'Annunzio, G.
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2010, 33 (06) : 406 - 408
  • [49] Glycocerebrosidase enzyme activity in Dried Blood Spot (DBS) sample is closely related to the number of leucocytes
    Dondurmaci, M.
    Sozmen, E.
    FEBS JOURNAL, 2016, 283 : 172 - 172
  • [50] Unsatisfactory dried blood spot sample rates: Does audit and feedback drive quality improvement?
    Dougan, Shelley
    McRoberts, Christine
    Dunn, Sandra
    Milburn, Jennifer
    Sprague, Ann
    Chakraborty, Pranesh
    CLINICAL BIOCHEMISTRY, 2014, 47 (15) : 133 - 133