Study on simulation and experiment of the magnetizer in magnetic flux leakage testing

被引:4
|
作者
Xiuli, Chai [1 ]
Dechang, Zeng [1 ]
Guixiong, Liu [1 ]
机构
[1] S China Univ Technol, Sch Mech Engn, Guangzhou, Guangdong, Peoples R China
关键词
magnetizer; magnetic flux leakage; finite element method; giant magnetic resistive sensor;
D O I
10.1109/ICMA.2007.4304053
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As a type of research tool, the finite element method (FEM) has been widely used in engineering designs and other fields. In this paper, the magnetic circuit character of the magnetizer was studied using the finite element method and related experiments. For a type of permanent magnet multiloop magnetizer, the magnetic field distribution of the inner and 2 mm above the surface of the ferromagnetic bar was analysed with two important sizes varying. In the experiments, the high sensitive giant magnetic resistive sensor was employed. Changing the two parameters, the length index related with magnetization effect of the magnetizer was measured. The experimental results are qualitatively in agreement with the simulation. It is considered that this method will help in the parameter optimization of the device.
引用
收藏
页码:3083 / 3087
页数:5
相关论文
共 50 条
  • [21] Study on local magnetization of magnetic flux leakage testing for storage tank floors
    Liu, Z
    Kang, Y
    Wu, X
    Yang, S
    INSIGHT, 2003, 45 (05) : 328 - 331
  • [22] Study on effect factors of sensor performance in pulsed magnetic flux leakage testing
    Tang, Ying
    Pan, Mengchun
    Luo, Feilu
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (12): : 2875 - 2880
  • [23] Magnetic flux leakage testing: Strong or weak magnetization
    Sukhorukov, V. (vsukhorukov@intron-plus.com), 1600, American Society for Nondestructive Testing (71):
  • [24] Magnetic Flux Leakage Testing Strong or Weak Magnetization?
    Sukhorukov, Vasily
    MATERIALS EVALUATION, 2013, 71 (05) : 26 - 31
  • [25] MAGNETIC FLUX LEAKAGE TESTING MECHANISM AND ITS APPLICATION
    Xiong, Er-Gang
    Wang, She-Liang
    Zhang, Jun-Feng
    Li, Bo
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 154 - 158
  • [26] 3-d FEM simulation of velocity effects on magnetic flux leakage testing signals
    Du Zhiye
    Ruan Jiangjun
    Peng Ying
    Yu Shifeng
    Zhang Yu
    Gan Yan
    Li Tianwei
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (06) : 1642 - 1645
  • [27] Numerical simulation of a magnetic flux leakage benchmark problem
    Ruch, M
    Bastos, JPA
    INSIGHT, 2004, 46 (12) : 736 - 741
  • [28] Nonlinear Simulation of a Magnetic Flux Leakage Measurement System
    Kovacs, Gergely
    Kuczmann, Miklos
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 184 - 187
  • [29] SIMULATION OF MAGNETIC FLUX LEAKAGE: APPLICATION TO TUBE INSPECTION
    Premel, Denis
    Fnaeich, E. A.
    Djafa, S.
    Pichon, L.
    Trillon, A.
    Bisiaux, B.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 31A AND 31B, 2012, 1430 : 1918 - 1925
  • [30] Research on magnetic inversion in alternating current magnetic flux leakage testing
    Wang, Gang
    Liang, Ce
    Song, Huadong
    Xiao, Qi
    Zhong, Yuan
    INSIGHT, 2023, 65 (06) : 319 - 326