Study on simulation and experiment of the magnetizer in magnetic flux leakage testing

被引:4
|
作者
Xiuli, Chai [1 ]
Dechang, Zeng [1 ]
Guixiong, Liu [1 ]
机构
[1] S China Univ Technol, Sch Mech Engn, Guangzhou, Guangdong, Peoples R China
关键词
magnetizer; magnetic flux leakage; finite element method; giant magnetic resistive sensor;
D O I
10.1109/ICMA.2007.4304053
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As a type of research tool, the finite element method (FEM) has been widely used in engineering designs and other fields. In this paper, the magnetic circuit character of the magnetizer was studied using the finite element method and related experiments. For a type of permanent magnet multiloop magnetizer, the magnetic field distribution of the inner and 2 mm above the surface of the ferromagnetic bar was analysed with two important sizes varying. In the experiments, the high sensitive giant magnetic resistive sensor was employed. Changing the two parameters, the length index related with magnetization effect of the magnetizer was measured. The experimental results are qualitatively in agreement with the simulation. It is considered that this method will help in the parameter optimization of the device.
引用
收藏
页码:3083 / 3087
页数:5
相关论文
共 50 条
  • [1] Magnetic flux leakage testing theory and method for magnetizer end inspection
    Cheng, SF
    Wu, XJ
    Kang, YH
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 636 - 641
  • [2] Experiment and simulation on testing steel plate with corrosion defects via magnetic flux leakage method
    School of Civil Engineering, Xi'an University of Architecture and Technology, Shaanxi, Xi'an
    710055, China
    不详
    710055, China
    J Magn Magn Mater,
  • [3] Experiment and simulation on testing steel plate with corrosion defects via magnetic flux leakage method
    Su, Sanqing
    Wang, Pu
    Shi, Pengpeng
    Hao, Shuai
    Liang, Tianshou
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2022, 560
  • [4] Deep neural network for simulation of magnetic flux leakage testing
    Minhhuy Le
    Cong-Thuong Pham
    Lee, Jinyi
    MEASUREMENT, 2021, 170
  • [5] Experiment and simulation study of 3D magnetic field sensing for magnetic flux leakage defect characterisation
    Li, Yong
    Wilson, John
    Tian, Gui Yun
    NDT & E INTERNATIONAL, 2007, 40 (02) : 179 - 184
  • [6] Design of a lightweight magnetizer to enable a portable circumferential magnetic flux leakage detection system
    Hong Quang Pham
    Van Sy Le
    Minh Hung Vu
    Duy Tuan Doan
    Quang Hung Tran
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (07):
  • [7] A comparative study of 3D and axisymmetric magnetizer assemblies used in magnetic flux leakage inspection of pipelines
    Katragadda, G
    Si, JT
    Lord, W
    Sun, YS
    Udpa, S
    Udpa, L
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (03) : 1573 - 1576
  • [8] Study on Design of Magnetic Flux Leakage Testing Instrument for gun
    WangChanglong FuJunmeiInstitute of Electronic and Information Xian Jiaotong UniversityYingwei XuZhangsuiOrdnance Engineering College Shijiazhuang ChinaWangChanglong Jin
    微计算机信息, 2005, (06) : 115 - 116+82
  • [9] Optimisation of the flux distribution in magnetic flux leakage testing
    Norouzi, E.
    Ravanbod, H.
    INSIGHT, 2009, 51 (10) : 563 - 567
  • [10] Optimization of the Flux Distribution in Magnetic Flux Leakage Testing
    Norouzi, E.
    Ravanbod, H.
    MATERIALS EVALUATION, 2010, 68 (03) : 360 - 364