Individualized 4-dimensional computed tomography proton treatment for pancreatic tumors

被引:3
|
作者
Knecht, Matthew L. [1 ]
Wang, Ning [1 ]
Vassantachart, April [1 ]
Mifflin, Rachel [1 ]
Slater, Jerry D. [1 ]
Yang, Gary Y. [1 ]
机构
[1] Loma Linda Univ, Med Ctr, James M Slater MD Proton Treatment & Res Ctr, 11234 Anderson St, Loma Linda, CA 92354 USA
关键词
Proton; stereotactic body radiotherapy; 4 dimensional computed tomography (4D CT); RADIATION-THERAPY; DESIGN; MOTION;
D O I
10.21037/jgo.2016.12.10
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The goal of this study is to determine whether a phase or reconstruction of a 10-phase 4 dimensional computed tomography (4D CT) scan can be used as the primary planning scan for proton treatment of the pancreas, thus eliminating the need for second a slow CT or free breathing CT. Methods: Ten patients with pancreatic adenocarcinoma were simulated with 4D CT and a proton treatment plan generated based upon one of three primary planning scans, the T0 phase, T50 phase or average reconstruction. These plans were then exported to each of the remaining phases of the 4D CT and the dose to 95% of the target (D95) calculated. Plans were deemed adequate if the D95 remained at 99% of the prescribed dose or greater. Results: For the ten patients in this study anterior abdominal motion was found to range from 2-27 mm (mean 7.50 +/- 6.79 mm). For 9 of 10 patients the anterior abdominal motion was <= 8 mm and all three primary planning scans provided adequate target coverage, resulting in minimum D95 coverage per plan of T0_plan 99.7%, T50_plan 99.3% and AVE_plan 99%. However no plan provided adequate target coverage on the single patient with the largest anterior abdominal motion, 27 mm, and cranio-caudal motion, 20 mm, with minimum D95 values of T0_plan 96.3%, T50_plan 68%, and AVE_plan 68%. Conclusions: The primary plans tested based up on the T0, T50 and average reconstructions provided adequate D95 coverage throughout the respiratory cycle as long as the anterior abdominal motion was <= 8 mm and can be considered for use as the primary proton planning scan.
引用
收藏
页码:675 / 682
页数:8
相关论文
共 50 条
  • [1] Individualized 4-Dimensional Computed Tomography Proton Treatment for Pancreatic Tumors
    Knecht, M. L.
    Wang, N.
    Vassantachart, A.
    Mifflin, R.
    Slater, J. D.
    Yang, G. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E183 - E184
  • [2] 4-dimensional computed tomography imaging and treatment planning
    Keall, P
    SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 81 - 90
  • [3] Frameless Image-Guided Stereotactic Body Radiation Therapy for Lung Tumors with 4-Dimensional Computed Tomography or 4-Dimensional Positron Emission Tomography/Computed Tomography
    Nath, Sameer K.
    Sandhu, Ajay P.
    Jensen, Lindsay
    Kim, Daniel
    Bharne, Anjali
    Nobiensky, Polly D.
    Lawson, Joshua D.
    Fuster, Mark M.
    Bazhenova, Lyudmilla
    Song, William Y.
    Mundt, Arno J.
    CLINICAL LUNG CANCER, 2011, 12 (03) : 180 - 186
  • [4] Modeling Pancreatic Tumor Motion Using 4-Dimensional Computed Tomography and Surrogate Markers
    Huguet, Florence
    Yorke, Ellen D.
    Davidson, Margaret
    Zhang, Zhigang
    Jackson, Andrew
    Mageras, Gig S.
    Wu, Abraham J.
    Goodman, Karyn A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (03): : 579 - 587
  • [5] Accuracy of 4-Dimensional Computed Tomography for Localization in Primary Hyperparathyroidism
    Eller, Michael
    Dave, Atman
    Johnson, Craig
    Fingeret, Abbey L.
    JOURNAL OF SURGICAL RESEARCH, 2021, 257 : 15 - 21
  • [6] Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, Salim
    Weiss, Elisabeth
    Jan, Nuzhat
    Roman, Nicholas
    Sleeman, William C.
    Fatyga, Mirek
    Christensen, Gary E.
    Zhang, Cheng
    Murphy, Martin J.
    Lu, Jun
    Keall, Paul
    Williamson, Jeffrey F.
    Hugo, Geoffrey D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 372 - 379
  • [7] Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography
    Pan, Tinsu
    Zaidi, Habib
    PET CLINICS, 2013, 8 (01) : 37 - +
  • [8] Computed tomography of pancreatic tumors
    Grenacher, L.
    Klauss, M.
    RADIOLOGE, 2009, 49 (02): : 107 - 123
  • [9] Characterization of Thyroid Nodules by 4-Dimensional Computed Tomography: Initial Experience
    Fitzgerald, Ryan T.
    Kuruva, Manohar
    David, Ryan
    Samant, Rohan S.
    Kumar, Manoj
    Van Hemert, Rudy
    Angtuaco, Edgardo J.
    Bodenner, Donald
    Stack, Brendan C., Jr.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (02) : 195 - 198
  • [10] Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography
    Rodgers, Steven E.
    Hunter, George J.
    Hamberg, Leena M.
    Schellingerhout, Dawid
    Doherty, David B.
    Ayers, Gregory D.
    Shapiro, Suzanne E.
    Edeiken, Beth S.
    Truong, Mylene T.
    Evans, Douglas B.
    Lee, Jeffrey E.
    Perrier, Nancy D.
    SURGERY, 2006, 140 (06) : 932 - 940