INFLUENCE OF BREATHING RESISTANCE OF HEAT AND MOISTURE EXCHANGERS ON TRACHEAL CLIMATE AND BREATHING PATTERN IN LARYNGECTOMIZED INDIVIDUALS

被引:17
|
作者
Scheenstra, Renske J. [1 ]
Muller, Sara H. [2 ]
Vincent, Andrew [3 ]
Sinaasappel, Michiel [2 ]
Hilgers, Frans J. M. [1 ,4 ,5 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[2] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Nucl Med Radiol, Amsterdam, Netherlands
[3] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Biostat, Amsterdam, Netherlands
[4] Univ Amsterdam, Inst Phonet Sci ACLC, NL-1012 WX Amsterdam, Netherlands
[5] Univ Amsterdam, Acad Med Ctr, Dept Otorhinolaryngol, NL-1105 AZ Amsterdam, Netherlands
关键词
total laryngectomy; heat and moisture exchanger; tracheal climate; temperature and humidity; breathing resistance; PULMONARY REHABILITATION; RESPIRATORY SYMPTOMS; TEMPERATURE; HUMIDITY; AIRWAY; EMPHYSEMA; PRESSURE; PATIENT;
D O I
10.1002/hed.21293
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background. The aim of this study was to determine the influence of breathing resistance of heat and moisture exchangers (HMEs) on endotracheal climate and breathing pattern. Methods. Endotracheal temperature and humidity and tidal volumes were measured in 11 laryngectomized patients with a regularly used HME with "standard" breathing resistance (Pro-vox Normal HME; R-HME), a low breathing-resistance HME (Provox HiFlow HME; L-HME), and without HME. Results. Both R-HME and L-HME increased end-inspiratory humidity (+5.8 and 4.7 mgH(2)O/L, respectively), decreased end-inspiratory temperature (-1.6 and -1.0 degrees C, respectively). and prolonged the exhalation breath length to approximately 0.5 seconds. The R-HME significantly enlarged tidal volumes (0.07 L; p < .05). Conclusions. Both HMEs significantly improve tracheal climate. The R-HME has better moistening properties and a small but significant positive effect on tidal volume. Therefore, if the higher resistance is tolerated, the R-HME is the preferred pulmonary rehabilitation device. The L-HME is indicated if lower breathing resistance is required. (C) 2009 Wiley Periodicals, Inc. Head Neck 32: 1069-1078, 2010
引用
收藏
页码:1069 / 1078
页数:10
相关论文
共 50 条
  • [1] Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate
    Zuur, J. Karel
    Muller, Saar H.
    Vincent, Andrew
    Sinaasappel, Michiel
    de Jongh, Frans H. C.
    Hilgers, Frans J. M.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2008, 30 (08): : 1072 - 1082
  • [2] HEAT AND MOISTURE EXCHANGERS AND BREATHING FILTERS
    HEDLEY, RM
    ALLTGRAHAM, J
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (02) : 227 - 236
  • [3] THE WORK OF BREATHING WITH HEAT AND MOISTURE EXCHANGERS IN THE CIRCLE BREATHING SYSTEM
    OOI, R
    ANAES, FC
    WOOD, M
    ANAES, FC
    ANESTHESIOLOGY, 1993, 79 (3A) : A500 - A500
  • [4] Adjustable breathing resistance for laryngectomized patients: Proof of principle in a novel heat and moisture exchanger cassette
    Leemans, Maartje
    Muller, Sara H.
    van Alphen, Maarten J. A.
    Vallenduuk, Wim
    Dirven, Richard
    van den Brekel, Michiel W. M.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (04): : 1073 - 1087
  • [5] THE WORK OF BREATHING IMPOSED BY HEAT AND MOISTURE EXCHANGERS DURING WEANING
    OOI, R
    BROWNE, G
    SONI, N
    ANESTHESIOLOGY, 1993, 79 (3A) : A295 - A295
  • [6] Breathing resistance in heat and moisture exchanging devices
    Ainegren, Mats
    Hanstock, Helen
    Stenfors, Nikolai
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2022, 236 (02) : 97 - 105
  • [7] THE INFLUENCE OF BREATHING PATTERN ON SPECIFIC AIRWAYS RESISTANCE
    Kirkby, J. C.
    Sonnappa, S.
    Stocks, J.
    THORAX, 2010, 65 : A131 - A132
  • [8] Influence of thoracoabdominal pattern of breathing on respiratory resistance
    Gallego, J
    Benammou, S
    Vardon, G
    Chambille, B
    Denjean, A
    Lorino, H
    RESPIRATION PHYSIOLOGY, 1997, 108 (02): : 143 - 152
  • [9] In Vitro Evaluation of Heat and Moisture Exchangers Designed for Spontaneously Breathing Tracheostomized Patients
    Brusasco, Claudia
    Corradi, Francesco
    Vargas, Maria
    Bona, Margherita
    Bruno, Federica
    Marsili, Maria
    Simonassi, Francesca
    Santori, Gregorio
    Severgnini, Paolo
    Kacmarek, Robert M.
    Pelosi, Paolo
    RESPIRATORY CARE, 2013, 58 (11) : 1878 - 1885
  • [10] IN VITRO EVALUATION OF SIX DIFFERENT HEAT MOISTURE EXCHANGERS FOR SPONTANEOUSLY BREATHING TRACHEOSTOMIZED PATIENTS
    Brusasco, C.
    Corradi, F.
    Simonassi, F.
    Bona, M.
    Bruno, F.
    Marsili, M.
    Vargas, M.
    Pelosi, P.