Probabilistic PMU placement considering topological change in high voltage substations

被引:10
|
作者
Jelodar, Mehdi Taleshian [1 ]
Fini, Alireza Sheikhi [2 ]
机构
[1] Islamic Azad Univ, Islamshahr Branch, Dept Engn, Sayyad St,Namaz Sq, Islamshahr 3314767653, Iran
[2] Hormozgan Univ, Dept Elect Engn, Km 9 Minab Rd,POB 3995, Bandar Abbas, Iran
关键词
PMU placement; Busbar arrangement; Double busbar; Connection probability; POWER-SYSTEM OBSERVABILITY; PHASOR MEASUREMENT UNITS; STATE ESTIMATION; LIMITED NUMBER; RELIABILITY; CONSTRAINTS; CHANNELS;
D O I
10.1016/j.ijepes.2016.03.022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
WAMS and WAMPAC are developed recently in the world electrical networks. PMU forms the basis of WAMS networks by measuring the main electrical parameters (bus voltage and feeder current). It is not necessary to use PMU on all of the network buses for a full observability and many studies are done for optimizing PMU numbers and placement in electrical networks. Considering simple buses for the networks is a common assumption in these studies. While practically, the busbar arrangement is not simple in high voltage substations, especially in 230 and 400 kV substations. As a result, it is feasible under different utilization condition that the substations be sectionalized and turns into two separate buses. In this paper a modified PMU placement method is presented considering different busbar arrangement in substations and possibility of network topology variation due to feeders' connection exchange at substation breakers opening/closing. In the revised method, at first step an optimized placement is aimed for full observability of each network under all configurations and at the second step, an improved placement is the goal in which the network small value of unobservability is acceptable under certain degree of risk. The test results on IEEE standard networks are presented. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 50 条
  • [31] Voltage Stability-based PMU Placement Considering N-1 Line Contingency and Power System Reliability
    Putranto, Lesnanto Multa
    Hara, Ryoichi
    Kita, Hiroyuki
    Tanaka, Eiichi
    2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 120 - 125
  • [32] Weak bus-constrained PMU placement for complete observability of a connected power network considering voltage stability indices
    Babu, Rohit
    Raj, Saurav
    Bhattacharyya, Biplab
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2020, 5 (01)
  • [33] PMU placement for HVDe connected network considering united and islanded conditions
    Dalali, Milad
    Kargar, Hossein Kazemi
    9TH POWER SYSTEMS PROTECTION AND CONTROL CONFERENCE (PSPC2015), 2015, : 19 - 24
  • [34] PMU placement considering various arrangements of lines connections at complex buses
    Khorram, Ebrahim
    Jelodar, Mehdi Taleshian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 94 : 97 - 103
  • [35] Optimal PMU Placement Considering Reliability of Measurement System in Smart Grids
    Shahraeini, Mohammad
    Khormali, Shahla
    Alvandi, Ahad
    2022 12th International Conference on Computer and Knowledge Engineering, ICCKE 2022, 2022, : 205 - 210
  • [36] Substation-oriented PMU placement considering transformer tap settings
    Manousakis, Nikolaos M.
    Korres, George N.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [37] A PMU Placement Scheme Considering Realistic Costs and Modem Trends in Relaying
    Pal, Anamitra
    Vullikanti, Anil Kumar S.
    Ravi, S. S.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (01) : 552 - 561
  • [38] PMU Placement for State Estimation Considering Measurement Redundancy and Controlled Islanding
    Akhlaghi, Shahrokh
    Zhou, Ning
    Wu, N. Eva
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [39] PMU Placement to Reduce State Estimation Bias Considering Parameters Uncertainty
    Davoudi, Mehdi
    Muhammed, Elssodani Abdelhadi
    9TH POWER SYSTEMS PROTECTION AND CONTROL CONFERENCE (PSPC2015), 2015, : 55 - 58
  • [40] Redundant Observability PMU Placement in the Presence of Flow Measurements Considering Contingencies
    Esmaili, Masoud
    Gharani, Kiarash
    Shayanfar, Heidar Ali
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) : 3765 - 3773