Inadvertent Removal of a Right Ventricular Pacemaker Lead by a Knotted Transvenous Pacing Wire

被引:1
|
作者
Wiens, Evan J. [1 ]
Seifer, Colette M. [2 ]
Khoo, Clarence [2 ]
机构
[1] Univ Manitoba, Max Ready Coll Med, Dept Internal Med, Winnipeg, MB, Canada
[2] Univ Manitoba, Dept Internal Med, Winnipeg, MB, Canada
关键词
Knot; Loop; Right ventricular lead; Transvenous pacemaker;
D O I
10.5005/jp-journals-10071-23126
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We report an unusual complication of permanent pacemaker (PPM) implantation in a patient with a temporary transvenous pacemaker (TVP) in situ, In which the TVP lead formed a knot around the newly-placed right ventricular (RV) lead, complicating TVP removal. The case underscores the fact that suboptimal TVP lead placement, such as looping in the RV, can result in complications during implantation of a permanent pacemaker.
引用
收藏
页码:102 / 103
页数:2
相关论文
共 50 条
  • [31] Inadvertent ent asymptomatic right atrial perforation with epicardial pacing in a neonate: A rare complication of temporary transvenous cardiac pacing
    Reddy, SCB
    Saxena, A
    Iyer, KS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02): : 368 - 369
  • [32] Clinical Outcomes of Leadless Pacemaker Compared to Right Ventricular Pacing
    Vijayaraman, Pugazhendhi
    Zalavadia, Dipen
    Locke, Andrew
    Maher, Timothy
    Haseeb, Abdul
    Bahadur, Radhika
    Levy, Alexander
    Morcos, Ramez
    D'Avila, Andre
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (07) : 1754 - 1756
  • [33] PERCUTANEOUS REMOVAL OF TRANSVENOUS PACING LEAD PERFORATING THE HEART, PERICARDIUM, AND PLEURA
    DEUTSCH, LS
    DANG, H
    BRANDON, JC
    OTT, R
    ALLEN, B
    FUTERMAN, C
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) : 471 - 473
  • [34] Ventricular Safety Pacing Triggered by Right Ventricular Lead Dislodgement
    Singh, Mohita
    McCoy, Cody
    Daniels, James
    CIRCULATION, 2019, 140 (21) : 1766 - 1768
  • [35] Effects of right ventricular pacing on left ventricular ejection fraction in a pacemaker clinic
    Kobza, Richard
    Schoenenberger, Andreas W.
    Erne, Paul
    ACTA CARDIOLOGICA, 2012, 67 (05) : 577 - 582
  • [36] GUIDE WIRE PACING - NEW METHODS FOR RAPID CONVERSION OF A CARDIAC CATHETER INTO AN EMERGENCY TRANSVENOUS PACEMAKER
    GESSMAN, LJ
    GALLAGHER, JD
    MACMILLAN, RM
    CLARK, DL
    MARANHAO, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 469 - 469
  • [37] Congestive heart failure caused by transvenous pacemaker lead prolapse and associated right ventricular outflow tract obstruction in a dog
    Djani, D. M.
    Coleman, A. E.
    Rapoport, G. S.
    Schmiedt, C. W.
    Layher, J.
    Thomason, J. D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2016, 18 (04) : 391 - 397
  • [38] Transvenous pacemaker lead removal is safe and effective even in large vegetations:: An analysis of 53 cases of pacemaker lead endocarditis
    Ruttmann, E
    Hangler, HB
    Kilo, J
    Höfer, D
    Müller, LC
    Hintringer, F
    Müller, S
    Laufer, G
    Antretter, H
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (03): : 231 - 236
  • [39] Delayed Right-Ventricular Perforation of a Pacemaker Lead
    Jürgen Hörer
    Albrecht Will
    Christian Schreiber
    Pediatric Cardiology, 2011, 32
  • [40] Transvenous Lead Extraction in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy
    Barakat, Amr F.
    Zmaili, Mohammad A.
    Tarakji, Khaldoun G.
    Shah, Shailee
    Rehman, Karim Abdur
    Martin, David O.
    Brunner, Michael P.
    Saliba, Walid, I
    Kanj, Mohamed
    Ballout, Jad
    Baranowski, Bryan
    Cantillon, Daniel
    Niebauer, Mark
    Callahan, Thomas
    Dresing, Thomas
    Rickard, John
    Lindsay, Bruce D.
    Wilkoff, Bruce L.
    Wazni, Oussama M.
    Hussein, Ayman A.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (06) : 665 - 670