Evaluation of performance of pelvic CT-MR deformable image registration using two software programs

被引:9
|
作者
Ishida, Tomoya [1 ]
Kadoya, Noriyuki [1 ]
Tanabe, Shunpei [1 ]
Ohashi, Haruna [2 ]
Nemoto, Hikaru [1 ,4 ]
Dobashi, Suguru [3 ]
Takeda, Ken [3 ]
Jingu, Keiichi [1 ]
机构
[1] Tohoku Univ, Dept Radiat Oncol, Grad Sch Med, Sendai, Miyagi 9808574, Japan
[2] Tohoku Univ, Dept Radiat Technol, Grad Sch Hlth Sci, Sendai, Miyagi 9808574, Japan
[3] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Sendai, Miyagi 9808574, Japan
[4] Komagome Hosp, Tokyo Metropolitan Canc & Infect Dis Ctr, Tokyo 1138677, Japan
关键词
MRI-guided radiotherapy; deformable image registration (DIR); cost function; pelvis; GUIDED RADIOTHERAPY; ADAPTIVE RADIOTHERAPY; ALGORITHMS; ACCURACY; THERAPY; HEAD;
D O I
10.1093/jrr/rrab078
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We assessed the accuracy of deformable image registration (DIR) accuracy between CT and MR images using an open-source software (Elastix, from Utrecht Medical Center) and a commercial software (Velocity AI Ver. 3.2.0 from Varian Medical Systems, Palo Alto, CA, USA) software. Five male patients' pelvic regions were studied using publicly available CT, T1-weighted (T1w) MR, and T2-weighted (T2w) MR images. In the cost function of the Elastix, we used six DIR parameter settings with different regularization weights (Elastix(0), Elastix(0.01), Elastix(0.1), Elastix(1),Elastix(10) and Elastixi(100)). We used MR Corrected Deformable algorithm for Velocity AI. The Dice similarity coefficient (DSC) and mean distance to agreement (MDA) for the prostate, bladder, rectum and left and right femoral heads were used to evaluate DIR accuracy. Except for the bladder, most algorithms produced good DSC and MDA results for all organs. In our study, the mean DSCs for the bladder ranged from 0.75 to 0.88 (CT-Tlw) and from 0.72 to 0.76 (CT-T2w). Similarly, the mean MDA ranges were 2.4 to 4.9 mm (CT-Tlw), 4.6 to 5.3 mm (CT-T2w). For the Elastix, CT-T1w was outperformed CT-T2w for both DSCs and MDAs at Elastix0, Elastix0.01, and Elastix0.1. In the case of Velocity AI, no significant differences in DSC and MDA of all organs were observed. This implied that the DIR accuracy of CT and MR images might differ depending on the sequence used.
引用
收藏
页码:1076 / 1082
页数:7
相关论文
共 50 条
  • [21] CT-MR Image Registration and Fusion in Radiotherapy Target Volume Definition - Institutional Experience
    Djan, I.
    Petrovic, B.
    Erak, M.
    Baucal, M.
    Rutonjski, L.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S192 - S193
  • [22] Radiotherapy treatment planning: benefits of CT-MR image registration and fusion in tumor volume delineation
    Djan, Igor
    Petrovic, Borislava
    Erak, Marko
    Nikolic, Ivan
    Lucic, Silvija
    VOJNOSANITETSKI PREGLED, 2013, 70 (08) : 735 - 739
  • [23] Deformable MR-CT Image Registration Using an Unsupervised Synthesis and Registration Network for Neuro-Endoscopic Surgery
    Han, R.
    Jones, C. K.
    Ketcha, M. D.
    Wu, P.
    Vagdargi, P.
    Uneri, A.
    Lee, J.
    Luciano, M.
    Anderson, W. S.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2021: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11598
  • [24] Clinical feasibility of MR-assisted CT-based cervical brachytherapy using MR-to-CT deformable image registration
    Dyer, Brandon A.
    Yuan, Zilong
    Qiu, Jianfeng
    Shi, Liting
    Wright, Cari
    Benedict, Stanley H.
    Valicenti, Richard
    Mayadev, Jyoti S.
    Rong, Yi
    BRACHYTHERAPY, 2020, 19 (04) : 447 - 456
  • [25] Comparison of Two Commercially Available Software Platforms for Deformable Image Registration
    Tuohy, R.
    Stathakis, S.
    Mavroidis, P.
    Bosse, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 218 - 218
  • [26] Comparison of two deformable registration software using an in-house "deformable phantom"
    Koutsouvelis, N.
    Rouzaud, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 838 - 839
  • [27] Evaluation of deformable image registration accuracy for CT images of the thorax region
    Sarudis, Sebastian
    Karlsson, Anna
    Bibac, Dan
    Nyman, Jan
    Back, Anna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 191 - 199
  • [28] Performance Evaluation of Deformable Image Registration Systems - SmartAdapt® and Velocity™
    Kumar, M. Anil
    Hajare, Raghavendra
    Nath, Bhakti Dev
    Lakshmi, K. K. Sree
    Mahantshetty, Umesh M.
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 240 - 249
  • [29] Accuracy of Multi-Modality Deformable Image Registration with MR and CT in MR-IGRT System
    Sakasai, T.
    Kuwahara, J.
    Okamoto, H.
    Nishioka, S.
    Miura, Y.
    Igaki, H.
    Abe, Y.
    Itami, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E600 - E600
  • [30] MR to CT Registration of Brains using Image Synthesis
    Roy, Snehashis
    Carass, Aaron
    Jog, Amod
    Prince, Jerry L.
    Lee, Junghoon
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034