The effect of saline iontophoresis on skin integrity in human volunteers .1. Methodology and reproducibility

被引:17
|
作者
Camel, E
OConnell, M
Sage, B
Gross, M
Maibach, H
机构
[1] BECTON DICKINSON RES CTR,RES TRIANGLE PK,NC
[2] BECTOR DICKINSON TRANSDERMAL SYST,FAIR LAWN,NJ
来源
FUNDAMENTAL AND APPLIED TOXICOLOGY | 1996年 / 32卷 / 02期
关键词
D O I
10.1006/faat.1996.0120
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
This study, conducted in 36 human volunteers, was an evaluation of the effects of saline iontophoresis on skin temperature, irritation, and barrier function. The major objectives were to assess the effects of low-level ionic currents, to validate the proposed methodology of assessment, and to establish reproducibility in repeated saline iontophoresis applications. This was ?he first of a multistage study designed to assess the safety of 24-hr saline iontophoresis episodes at selected currents and current densities. Since an iontophoresis patch challenges the skin barrier both by occluding the skin surface and by passing ionic current through the skin, the experimental protocol was designed to permit measurement of the contribution of each of these processes to the overall response. In this first stage we investigated the effect of 10 min of current delivery, at 0.1 mA/cm(2) on a 1-cm(2) area patch and 0.2 mA/cm(2) on a 6.5-cm(2) area patch compared to unpowered control patches. Twelve subjects were tested under each condition on two separate occasions to examine reproducibility of the response variable measurements. A further 12 subjects were tested once under the 0.2 mA/cm(2), 6.5-cm(2) condition. Skin irritation was evaluated Via repeated measurements of transepidermal water loss, capacitance, skin temperature, skin color, and a visual scoring system, before the iontophoresis episode and after patch removal. No damage to skin barrier function in terms of skin-water loss or skin-water content wits detected. Slight, subclinical, short-lasting erythema was observed for both conditions. Assessment of correlation coefficients showed highly statistically significant indications of reproducibility for all five response variables measured. The experimental design, in combination with a repeated measures analysis, provided clear separation of the occlusion and ionic current components of the iontophoretic patch challenge. Further, the repeated measures analysis gave a highly sensitive assessment of skin irritation and resolution after patch removal. We conclude that the experimental methodology is appropriate for assessing possible changes in skin integrity resulting from saline iontophoresis under similar operating conditions for longer durations and for other skin challenges from which a subclinical response is expected. (C) 1996 Society of Toxicology
引用
收藏
页码:168 / 178
页数:11
相关论文
共 50 条
  • [21] IN VITRO CALCULOGENESIS WITH HUMAN URINE .1. METHOD + REPRODUCIBILITY OF RESULTS
    MCDONALD, DF
    MCFADDEN, A
    ROTH, L
    JOURNAL OF UROLOGY, 1964, 91 (06): : 676 - &
  • [22] Experimental Study of Temperature Effect on Human Skin: Discussion of Methodology
    Ismail, Ahmad Rasdan
    Abu Bakar, Rosli
    Jusoh, Norfadzilah
    CURRENT TRENDS IN ERGONOMICS, 2013, 10 : 71 - +
  • [23] Effect of altered human exposome on the skin and mucosal epithelial barrier integrity
    Pat, Yagiz
    Ogulur, Ismail
    Yazici, Duygu
    Mitamura, Yasutaka
    Cevhertas, Lacin
    Kucukkase, Ozan C.
    Mesisser, Sanne S.
    Akdis, Mubeccel
    Nadeau, Kari
    Akdis, Cezmi A.
    TISSUE BARRIERS, 2023, 11 (04):
  • [24] Effect of transdermal iontophoresis codelivery of hydrocortisone on metoclopramide pharmacokinetics and skin-induced reactions in human subjects
    Cormier, M
    Chao, ST
    Gupta, SK
    Haak, R
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1999, 88 (10) : 1030 - 1035
  • [25] Effect of elastic liquid-state vesicle on apomorphine iontophoresis transport through human skin in vitro
    Li, GL
    Danhof, M
    Bouwstra, JA
    PHARMACEUTICAL RESEARCH, 2001, 18 (11) : 1627 - 1630
  • [26] X-ray microanalysis of cryopreserved human skin to study the effect of iontophoresis on percutaneous ion transport
    Pechtold, LARM
    Boddé, HE
    Junginger, HE
    Koerten, HK
    Bouwstra, JA
    PHARMACEUTICAL RESEARCH, 2001, 18 (07) : 1012 - 1017
  • [27] Effect of Elastic Liquid-State Vesicle on Apomorphine Iontophoresis Transport Through Human Skin In Vitro
    Gai Ling Li
    Meindert Danhof
    Joke A. Bouwstra
    Pharmaceutical Research, 2001, 18 : 1627 - 1630
  • [28] HUMAN GINGIVAL LYMPHOCYTES .1. METHODOLOGY FOR THE ISOLATION OF HUMAN GINGIVAL LYMPHOCYTES
    MACKLER, BF
    WITHERS, JA
    WOODSON, DL
    COKER, E
    HERRIN, A
    FRIEDMAN, L
    ONEILL, PA
    JOURNAL OF DENTAL RESEARCH, 1979, 58 (10) : 1946 - 1952
  • [29] Effect of glove occlusion on human skin .1. Short-term experimental exposure
    Ramsing, DW
    Agner, T
    CONTACT DERMATITIS, 1996, 34 (01) : 1 - 5
  • [30] THE ANOMALOUS SKIN EFFECT AND THE REFLECTIVITY OF METALS .1.
    DINGLE, RB
    PHYSICA, 1953, 19 (03): : 311 - 347