Gas/Particle Flow Characteristics, Combustion and NOx Emissions of Down-Fired 600 MWe Supercritical Utility Boilers with Respect to Two Configurations of Combustion Systems

被引:20
|
作者
Kuang, Min [1 ]
Li, Zhengqi [1 ]
Zhu, Qunyi [1 ]
Chen, Lizhe [1 ]
Zhang, Yan [1 ]
Lai, Jinping [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
STAGED-AIR; FIELD;
D O I
10.1021/ef300324f
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Using a phase-Doppler anemometry (PDA) on a two-phase small-scale model for a down-fired 600-MW, supercritical utility boiler, experiments were conducted to compare the gas/particle flow characteristics between the prior and newly designed deep-air-staging combustion systems. The distributions of mean velocity, particle volume flux, and particle number concentration along several cross sections were compared between the two combustion systems, in addition to the decay and trajectory of the downward gas/particle flow. With the prior combustion system, asymmetric gas/particle flow characteristics appear in the furnace, with the gas/particle flows in the front-half of the furnace penetrating greatly further and occupying much more furnace volume than those in the rear-half of the furnace. The longitudinal gas/particle velocity components, particle volume flux, particle number concentration, decay curve, and trajectory of the downward gas/particle flow all display a severe asymmetric pattern along the furnace center. In applying the deep-air-staging combustion technology as a replacement for the prior art, the original asymmetric gas/particle flow characteristics that are seen in the furnace all develop a symmetric pattern. Industrial-sized measurements performed within the full-scale furnace uncovered that asymmetric combustion characterized by gas temperatures being much higher near the rear wall than near the front wall, developed in the boiler with the prior art. In comparison with the boiler with the prior art, the newly designed boiler applying the deep-air-staging combustion system achieved perfectly symmetric combustion, NOx emission reduction by around 40%, and large improvement in burnout.
引用
收藏
页码:3316 / 3328
页数:13
相关论文
共 50 条
  • [41] Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system
    Chen, Zhichao
    Wang, Qingxiang
    Wang, Bingnan
    Zeng, Lingyan
    Che, Miaomiao
    Zhang, Xin
    Li, Zhengqi
    APPLIED ENERGY, 2017, 189 : 133 - 141
  • [42] Establishing an overall symmetrical combustion setup for a 600 MWe supercritical down-fired boiler: A numerical and cold-modeling experimental verification
    Kuang, Min
    Wu, Haiqian
    Zhu, Qunyi
    Ti, Shuguang
    ENERGY, 2018, 147 : 208 - 225
  • [43] NUMERICAL SIMULATIONS OF COMBUSTION CHARACTERISTICS AND NOX EMISSIONS FOR TWO CONFIGURATIONS OF SWIRL COAL BURNERS IN A 300 MWe WALL-FIRED BOILER
    Li, Zhengqi
    Zeng, Lingyan
    Zhao, Guangbo
    Li, Jing
    Shen, Shanping
    Zhang, Fucheng
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2011, 60 (05) : 441 - 460
  • [44] Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios
    Liu, Chunlong
    Li, Zhengqi
    Jing, Xinjing
    Xie, Yiquan
    Zhang, Qinghua
    Zong, Qiudong
    ENERGY, 2014, 64 : 771 - 778
  • [45] Combustion and NOx Emission Characteristics with Respect to Staged-Air Damper Opening in a 600 MWe Down-Fired Pulverized-Coal Furnace under Deep-Air-Staging Conditions
    Kuang, Min
    Li, Zhengqi
    Wang, Zhihua
    Jing, Xinjing
    Liu, Chunlong
    Zhu, Qunyi
    Ling, Zhongqian
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (01) : 837 - 844
  • [46] Effect of burner location on flow-field deflection and asymmetric combustion in a 600 MWe supercritical down-fired boiler (vol 206, pg 1393, 2017)
    Kuang, Min
    Yang, Guohua
    Zhu, Qunyi
    Ti, Shuguang
    Wang, Zhenfeng
    APPLIED ENERGY, 2018, 229 : 1287 - 1288
  • [47] Combustion optimization and NOx reduction of a 600 MWe down-fired boiler by rearrangement of swirl burner and introduction of separated over-fire air
    Yang, Wu
    Wang, Ben
    Lei, Siyuan
    Wang, Ke
    Chen, Tao
    Song, Zijian
    Ma, Chuan
    Zhou, Yiding
    Sun, Lushi
    JOURNAL OF CLEANER PRODUCTION, 2019, 210 : 1120 - 1130
  • [48] Characterization of gas/particle flows with respect to staged-air ratio for a down-fired 600 MWe supercritical utility boiler with multiple injection and multiple staging: A lab-scale study
    Kuang, Min
    Li, Zhengqi
    Zhu, Qunyi
    Zhang, Hongyu
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 70 : 154 - 165
  • [49] Industrial measurement of combustion and NOx formation characteristics on a low-grade coal-fired 600MWe FW down-fired boiler retrofitted with novel low-load stable combustion technology
    Du, He
    Li, Zhengqi
    Liu, Zheng
    Zhang, Mingdi
    Huang, Chunchao
    Jiang, Guangfei
    Chen, Zhichao
    Song, Jian
    Fang, Fan
    Su, Jianjun
    Liu, Haibing
    FUEL, 2022, 321
  • [50] Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler
    Li, Zhengqi
    Ren, Feng
    Zhang, Jie
    Zhang, Xiaohui
    Chen, Zhichao
    Chen, Lizhe
    FUEL, 2007, 86 (15) : 2457 - 2462