Y-Stent-Assisted Coiling of Wide-Neck Bifurcation Intracranial Aneurysms: A Meta-Analysis

被引:71
|
作者
Cagnazzo, F. [1 ]
Limbucci, N. [1 ]
Nappini, S. [1 ]
Renieri, L. [1 ]
Rosi, A. [1 ]
Laiso, A. [1 ]
di Carlo, D. Tiziano [2 ]
Perrini, P. [2 ]
Mangiafico, S. [1 ]
机构
[1] Careggi Univ Hosp, Intervent Neuroradiol Unit, Florence, Italy
[2] Univ Pisa, Cisanello Hosp, Dept Neurosurg, Pisa, Italy
关键词
CEREBRAL-ARTERY ANEURYSMS; ENDOVASCULAR TREATMENT; WOVEN ENDOBRIDGE; CELL STENTS; EMBOLIZATION; CONFIGURATION; MULTICENTER; EXPERIENCE; EFFICACY; COMPLEX;
D O I
10.3174/ajnr.A5900
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Y-stent-assisted coiling for wide-neck intracranial aneurysms required further investigation. PURPOSE: Our aim was to analyze outcomes after Y-stent placement in wide-neck aneurysms. DATA SOURCES: We performed a systematic search of 3 data bases for studies published from 2000 to 2018. STUDY SELECTION: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting Y-stent-assisted coiling of wide-neck aneurysms. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and factors influencing the studied outcomes. DATA SYNTHESIS: We included 27 studies and 750 aneurysms treated with Y-stent placement. The immediate complete/near-complete occlusion rate was 82.2% (352/468; 95% CI, 71.4%-93%; I-2 = 92%), whereas the long-term complete/near-complete occlusion rate was 95.4% (564/598; 95% CI, 93.7%-97%; I-2 = 0%) (mean radiologic follow-up of 14 months). The aneurysm recanalization rate was 3% (20/496; 95% CI, 1.5%-4.5%; I-2 = 0%), and half of the recanalized aneurysms required retreatment. The treatment-related complication rate was 8.9% (63/614; 95% CI, 5.8%-12.1%; I-2 = 44%). Morbidity and mortality after treatment were 2.4% (18/540; 95% CI, 1.2%-3.7%; I-2 = 0%) and 1.1% (5/668; 95% CI, 0.3%-1.9%; I-2 = 0%), respectively. Crossing Y-stent placement was associated with a slightly lower complication rate compared with the kissing configuration (56/572 = 8.4%; 95% CI, 5%-11%; I-2 = 46% versus 4/30 = 12.7%; 95% CI, 3%-24%; I-2 = 0%). Occlusion rates were quite comparable among Enterprise, Neuroform, and LVIS stents, whereas the Enterprise stent was associated with lower rates of complications (8/89 = 6.5%; 95% CI, 1.6%-11%; I-2 = 0%) compared with the others (20/131 = 14%; 95% CI, 5%-26%; I-2 = 69% and 9/64 = 11%; 95% CI, 3%-20%; I-2 = 18%). LIMITATIONS: This was a small, retrospective series. CONCLUSIONS: Y-stent-assisted coiling yields high rates of long-term angiographic occlusion, with a relatively low rate of treatment-related complications. Y-stent placement with a crossing configuration appears to be associated with better outcomes. Although Y-configuration can be obtained using many types of stents with comparable occlusion rates, the Enterprise stent is associated with lower complication rates.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 50 条
  • [21] Evaluation of short- and long-term results of Y-stent-assisted coiling with Leo stents in endovascular treatment of wide-necked intracranial bifurcation aneurysms
    Suleyman, Kanullah
    Korkmazer, Bora
    Kocer, Naci
    Islak, Civan
    Kizilkilic, Osman
    NEURORADIOLOGY, 2023, 65 (04) : 785 - 791
  • [22] Stent-Assisted Coiling Versus Balloon Remodeling of Wide-Neck Aneurysms: Comparison of Angiographic Outcomes
    Chalouhi, N.
    Starke, R. M.
    Koltz, M. T.
    Jabbour, P. M.
    Tjoumakaris, S. I.
    Dumont, A. S.
    Rosenwasser, R. H.
    Singhal, S.
    Gonzalez, L. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1987 - 1992
  • [23] Stent assisted coiling versus non-stent assisted coiling for the management of ruptured intracranial aneurysms: a meta-analysis and systematic review
    Zhang, Xiaoxi
    Zuo, Qiao
    Tang, Haishuang
    Xue, Gaici
    Yang, Pengfei
    Zhao, Rui
    Li, Qiang
    Fang, Yibin
    Xu, Yi
    Hong, Bo
    Huang, Qinghai
    Liu, Jianmin
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (05) : 489 - 496
  • [24] Stent-assisted coiling and balloon-assisted coiling in the management of intracranial aneurysms: A systematic review & meta-analysis
    Wang, Fei
    Chen, Xun
    Wang, Yong
    Bai, Peng
    Wang, Huan-zhi
    Sun, Tao
    Yu, Hua-lin
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2016, 364 : 160 - 166
  • [25] The Woven EndoBridge device as a good alternative treatment for stent assisted coiling in intracranial bifurcation aneurysms: a systematic review and meta-analysis
    Ohadi, Mohammad Amin Dabbagh
    Asef, Seyyed Amir
    Zamani, Raha
    Dashtkoohi, Mohammad
    Musmar, Basel
    Zomorodi, Ali
    Hasan, David
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [26] Stents and Stent Mimickers in Endovascular Management of Wide-neck Intracranial Aneurysms
    Khattak, Yasir J.
    Sibaie, Ayman A.
    Anwar, Muhammad
    Sayani, Raza
    CUREUS, 2018, 10 (10):
  • [27] Stent, balloon-assisted coiling and double microcatheter for treating wide-neck aneurysms in anterior cerebral circulation
    Pan, Jianwei
    Xiao, Feng
    Szeder, Viktor
    Yan, Ming
    Fan, Weijian
    Gu, Jun
    He, Lingna
    Zhan, Renya
    NEUROLOGICAL RESEARCH, 2013, 35 (10) : 1002 - 1008
  • [28] Stent-Assisted Coiling of Wide-Neck Intracranial Aneurysms Using Low-Profile LEO Baby Stents: Initial and Midterm Results
    Aydin, K.
    Arat, A.
    Sencer, S.
    Barburoglu, M.
    Men, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) : 1934 - 1941
  • [29] STENT REMODELING TECHNIQUE FOR COILING OF RUPTURED WIDE-NECK CEREBRAL ANEURYSMS: CASE REPORT
    Lopes, Demetrius K.
    Wells, Kalani
    NEUROSURGERY, 2009, 65 (05) : 1007 - 1008
  • [30] eCLIPs bifurcation remodeling system for treatment of wide-neck bifurcation aneurysms: A systematic review and meta-analysis of safety and efficacy
    Ghozy, Sherief
    Ramzan, Abdullah
    Kobeissi, Hassan
    Motawei, Ahmed Sallam
    Abdelghaffar, Mariam
    Dmytriw, Adam A.
    Kallmes, David F.
    Kadirvel, Ramanathan
    NEURORADIOLOGY JOURNAL, 2024, 37 (06): : 699 - 704