Prediction of thermal comfort, IAQ, and energy consumption in a dense occupancy environment with the under floor air distribution system

被引:46
|
作者
Fathollahzadeh, Mohammad Hassan [1 ]
Heidarinejad, Ghassem [1 ]
Pasdarshahri, Hadi [1 ]
机构
[1] Tarbiat Modares Univ, Fac Mech Engn, Tehran, Iran
关键词
Under floor air distribution system; Large indoor environment; Return air vent height; Energy consumption; Thermal comfort; SUPPLY DISPLACEMENT VENTILATION; DISTRIBUTION UFAD SYSTEM; OFFICE;
D O I
10.1016/j.buildenv.2015.03.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this study is to investigate an under floor air distribution (UFAD) system with combined and separate return and exhaust air vents regarding thermal comfort, indoor air quality (IAQ), and energy consumption. This ventilation system is used in a large indoor environment (dense occupancy), and two common types of inlet diffusers (direct and swirl) are used. Computational fluid dynamics (CFD) methods are used to predict thermal comfort conditions of occupants, IAQ and energy consumption in this space. Based on the results, direct inlet diffusers cannot lead to an acceptable temperature gradient in vertical direction in none of the examined return air vent positions, but swirl inlet diffusers can lead to an acceptable one. By precisely considering thermal comfort conditions, and IAQ made by swirl inlet diffusers, opting the upper boundary of the occupied zone (1.7 m) for return air vent position (which is the optimum case study among all the examined case studies) can lead to the best results. Moreover, the optimum return air vent position in this UFAD system can result to 10.5 percent reduction in the amount of energy consumption compared to the mixing ventilation system. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:96 / 104
页数:9
相关论文
共 50 条
  • [41] Numerical simulation for energy consumption and thermal comfort in a naturally ventilated indoor environment under different orientations of inlet diffuser
    Ganesh, Ghogare Abhijeet
    Sinha, Shobha Lata
    Verma, Tikendra Nath
    Dewangan, Satish Kumar
    BUILDING AND ENVIRONMENT, 2022, 217
  • [42] Dynamic Performance of Indoor Environment and Energy Consumption of Air Conditioning System under Intermittent Mode
    Shan, Xiaofang
    Lu, Wei-Zhen
    Hui, Shichang
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 3821 - 3826
  • [43] Study on Comfort Environment Oriented Building Energy Consumption Intelligent Management System
    Guan, Qiang
    Liu, Yu
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 5880 - 5884
  • [44] Effects of indoor environment on EEG and thermal comfort under the ceiling-fan-integrated air conditioning system
    Li, Wenqiang
    Peng, Pei
    Wang, Tao
    Gong, Guangcai
    BUILDING AND ENVIRONMENT, 2024, 257
  • [45] Thermal comfort and energy consumption in cold environment with retrofitted Huotong (warm-barrel)
    He, Yingdong
    Li, Nianping
    Zhou, Linxuan
    Wang, Kuan
    Zhang, Wenjie
    BUILDING AND ENVIRONMENT, 2017, 112 : 285 - 295
  • [46] Impact of window parameters on the building envelope on the thermal comfort, energy consumption and cost and environment
    Elghamry, Rania
    Hassan, Hamdy
    INTERNATIONAL JOURNAL OF VENTILATION, 2020, 19 (04) : 233 - 259
  • [47] Enthalpy estimation for thermal comfort and energy saving in air conditioning system
    Chu, Chi-Min
    Jong, Tai-Lang
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1620 - 1628
  • [48] Building Energy Simulation, CFD and prototype testing to design an effective Under Floor Air Distribution System
    Webb, Matthew
    LIVING AND LEARNING: RESEARCH FOR A BETTER BUILT ENVIRONMENT, 2015, : 487 - 496
  • [49] Investigating thermal performance and energy efficiency in under-floor air distribution data centers: A case study
    Feng, Xiumin
    Zhang, Zhongbin
    Zhang, Yu
    Zhang, Yuxuan
    Yao, Yuan
    Wang, Xiaolin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 54
  • [50] Energy analysis of under-floor air distribution (UFAD) system: An office building case study
    Alajmi, Ali F.
    Abou-Ziyan, Hosny Z.
    El-Amer, Wid
    ENERGY CONVERSION AND MANAGEMENT, 2013, 73 : 78 - 85