摘要
A method for inducing a forced DC crossing applied to a Direct Current Circuit Breaker (DCCB) for High Voltage Direct Current (HVDC) applications is described. A low voltage prototype was developed, and theoretical analysis was done on the circuit to derive an expression for the fault clearance time. The circuit was modelled on PLECS for verification of the working principle. Hardware was fabricated for a 40 VDC, 2 A continuous current rating; the ideal analytical expression for fault clearance time was verified from the experimental value, which was observed to be 62.76 mu S. Work described is covered by US Patent Publication No. 2017/0345587.
引用
收藏
页码:1047 / 1051
页数:5
相关论文
共 50 条
  • [41] DC Circuit Breaker Using Superconductor for Current Limiting
    Xiang, Bin
    Liu, Zhiyuan
    Geng, Yingsan
    Yanabu, Satoru
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (02)
  • [42] Current Flow Controlling Hybrid DC Circuit Breaker
    Mokhberdoran, Ataollah
    Gomis-Bellmunt, Oriol
    Silva, Nuno
    Carvalho, Adriano
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (02) : 1323 - 1334
  • [43] A Fault Current Limiting Hybrid DC Circuit Breaker
    Huang L.
    Zhang Q.
    Liu W.
    Liu R.
    Energy Engineering: Journal of the Association of Energy Engineering, 2022, 119 (02): : 621 - 636
  • [44] Study on High Frequency Current Interruption Characteristics of Vacuum Circuit Breaker
    Kojima, Koki
    Oshiro, Ryoji
    Kaneko, Eiji
    PROCEEDINGS OF THE 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 1, 2016, : 181 - 184
  • [45] Experimental investigation on the characteristics of vacuum arc in the process of DC interruption based on artificial current zero
    Song, Xiaochuan
    Shi, Zongqian
    Liu, Chang
    Yang, Hongyi
    Ma, Ming
    Jia, Shenli
    Wang, Lijun
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 292 - 295
  • [46] Simulation on the Residual Axial Magnetic Field in Vacuum DC Interruption Based on Artificial Current Zero
    Zhang, Yingkui
    Shi, Zongqian
    Li, Junliang
    Wang, Qiaosen
    Jia, Shenli
    Wang, Lijun
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [47] Interrupter Size Effect of High-Voltage Gas Circuit Breaker on Thermal Interruption Performance and Current Zero Properties
    Sakuyama, Toshiaki
    Kotsuji, Hideyuki
    Terada, Masanao
    Shiraishi, Katsuhiko
    Urai, Hajime
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 16 (02) : 215 - 225
  • [48] Cascaded commutation circuit for a hybrid DC breaker with dynamic control on fault current and DC breaker voltage
    Shan, Yunhai
    Lim, Tee C.
    Finney, Stephen J.
    Guang, Weixiao
    Williams, Barry W.
    Holliday, Derrick
    Ding, Xiao
    IET POWER ELECTRONICS, 2017, 10 (06) : 676 - 686
  • [49] CURRENT ZERO FLOW CONDITIONS IN A CIRCUIT BREAKER-NOZZLE
    TAYLOR, S
    FANG, MTC
    JONES, GR
    SHIMMIN, DW
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1991, 138 (05): : 259 - 264
  • [50] Effect of arcing time upon the interruption characteristic of the hybrid DC vacuum circuit breaker
    Liu, Luhui
    Zhuang, Jinwu
    Wang, Chen
    Jiang, Zhuangxian
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (24): : 55 - 60