Round robin test: Wear of nine dental restorative materials in six different wear simulators - Supplement to the round robin test of 2005

被引:39
|
作者
Heintze, S. D. [1 ]
Barkmeier, W. W. [2 ]
Latta, M. A. [2 ]
Rousson, V. [3 ]
机构
[1] Ivoclar Vivadent AG, R&D, FL-9494 Schaan, Liechtenstein
[2] Creighton Univ, Sch Dent, Dept Gen Dent, Omaha, NE 68178 USA
[3] Univ Lausanne, Biostat Unit, Inst Social & Prevent Med, CH-1015 Lausanne, Switzerland
关键词
Wear; Round robin test; In vitro; Composite; Ceramic; Amalgam; Wear simulator; IN-VITRO WEAR; COMPOSITE WEAR; CLINICAL WEAR; RESIN COMPOSITES; AMALGAM; DEVICE;
D O I
10.1016/j.dental.2010.09.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. Methods. Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam(Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. Results. Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. Significance. As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material. (C) 2010 Published by Elsevier Ltd on behalf of Academy of Dental Materials. All rights reserved.
引用
收藏
页码:E1 / E9
页数:9
相关论文
共 50 条
  • [41] The glass transition temperature of polystyrene - Results of a round robin test
    Rieger, J
    JOURNAL OF THERMAL ANALYSIS, 1996, 46 (3-4): : 965 - 972
  • [42] Round-Robin test of split Hopkinson pressure bar
    Kariem, Muhammad A.
    Santiago, Rafael C.
    Govender, Reuben
    Shu, Dong Wei
    Ruan, Dong
    Nurick, Gerald
    Alves, Marcilio
    Lu, Guoxing
    Langdon, Genevieve S.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2019, 126 : 62 - 75
  • [43] Round robin test for size characterization of airborne silica nanoparticles
    Takahata, Keiji
    Ehara, Kensei
    Motzkus, Charles
    Mace, Tatiana
    Vaslin-Reimann, Sophie
    29TH SYMPOSIUM ON AEROSOL SCIENCE AND TECHNOLOGY, 2012, 2012, : 93 - 94
  • [44] Results of the ASTM Instrumented/Miniaturized Round Robin Test Program
    Manahan, MP
    Martin, FJ
    Stonesifer, RB
    PENDULUM IMPACT TESTING: A CENTURY OF PROGRESS, 2000, (1380): : 223 - 241
  • [45] LAROCQUE PRINTABILITY TEST - ROUND-ROBIN AMONG LABS
    DEGRACE, JH
    PAGE, DH
    PULP & PAPER-CANADA, 1979, 80 (10) : 86 - 88
  • [46] ROUND-ROBIN TEST TO REVISE PRESSURE RATING STANDARD
    不详
    HYDRAULICS & PNEUMATICS, 1979, 32 (07) : 82 - &
  • [47] BEREAL - METHOD FOR PELLET STOVES: FIELD TEST AND ROUND ROBIN
    Bachmaier, H.
    Oehler, H.
    Hartmann, H.
    Ronnback, M.
    Persson, H.
    Jespersen, M. G.
    Jensen, J. H.
    Ch, Schmidl
    Reichert, G.
    Pelz, S.
    Woehler, M.
    PAPERS OF THE 25TH EUROPEAN BIOMASS CONFERENCE, 2017, : 642 - 647
  • [48] International round-robin study on the Ames fluctuation test
    Reifferscheid, G.
    Maes, H. M.
    Allner, B.
    Badurova, J.
    Belkin, S.
    Bluhm, K.
    Brauer, F.
    Bressling, J.
    Domeneghetti, S.
    Elad, T.
    Flueckiger-Isler, S.
    Grummt, H. J.
    Guertler, R.
    Hecht, A.
    Heringa, M. B.
    Hollert, H.
    Huber, S.
    Kramer, M.
    Magdeburg, A.
    Ratte, H. T.
    Sauerborn-Klobucar, R.
    Sokolowski, A.
    Soldan, P.
    Smital, T.
    Stalter, D.
    Venier, P.
    Ziemann, Chr.
    Zipperle, J.
    Buchinger, S.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2012, 53 (03) : 185 - 197
  • [49] Density Determination of Sintered Steel - Results of a Round Robin Test
    Peters, R.
    Beiss, P.
    Lindlohr, S.
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2019, 56 (11): : 731 - 746
  • [50] Round-robin test for flatness measurement of GaAs wafers