Evaluation of a green laser pointer for flow cytornetry

被引:29
|
作者
Habbersett, Robert C. [1 ]
Naivar, Mark A. [1 ]
Woods, Travis A. [1 ]
Goddard, Gregory R. [1 ]
Graves, Steven W. [1 ]
机构
[1] Los Alamos Natl Lab, Biosci Div, Los Alamos, NM 87545 USA
关键词
flow cytometry; DPSS laser; laser pointer; portable;
D O I
10.1002/cyto.a.20454
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometers typically incorporate expensive lasers with high-quality (TEM00) output beam structure and very stable output power, significantly increasing system cost and power requirements. Red diode lasers minimize power consumption and cost, but limit fluorophore selection. Low-cost DPSS laser pointer modules could possibly offer increased wavelength selection but presumed emission instability has limited their use. A $160 DPSS 532 nm laser pointer module was first evaluated for noise characteristics and then used as the excitation light source in a custom-built flow cytometer for the analysis of fluorescent calibration and alignment microspheres. Eight of ten modules tested were very quiet (RMS noise <= 0.6% between 0 and 5 MHz). With a quiet laser pointer module as the light source in a slow-flow system, fluorescence measurements from alignment microspheres produced CVs of about 3.3%. Furthermore, the use of extended transit times and <= 1 mW of laser power produced both baseline resolution of all 8 peaks in a set of Rainbow microspheres, and a detection limit of <20 phycoerythrin molecules per particle. Data collected with the transit time reduced to 25 mu s (in the same instrument but at 2.4 mW laser output) demonstrated a detection limit of similar to 75 phycoerythrin molecules and CVs of about 2.7%. The performance, cost, size, and power consumption of the tested laser pointer module suggests that it may be suitable for use in conventional flow cytometry, particularly if it were coupled with cytometers that support extended transit times. Published 2007 Wiley-Liss, Inc.
引用
收藏
页码:809 / 817
页数:9
相关论文
共 50 条
  • [41] Macular Hole from a Laser Pointer
    Androudi, Sofia
    Papageorgiou, Eleni
    NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (25): : 2420 - 2420
  • [42] Interaction with laser pointer on large screens
    Knudsen, R
    Enig, T
    Perge, DAE
    Mogensen, P
    HUMAN-COMPUTER INTERACTION - INTERACT'01, 2001, : 775 - 776
  • [43] Laser pointer safety regulation status
    Murphy, Patrick
    LASER FOCUS WORLD, 2017, 53 (06): : 31 - 31
  • [44] The selection of high-producing cell lines using flow cytornetry and cell sorting
    Carroll, S
    Al-Rubeai, M
    EXPERT OPINION ON BIOLOGICAL THERAPY, 2004, 4 (11) : 1821 - 1829
  • [45] Intracellular cytokine detection by flow cytornetry in pigs: Fixation, permeabilization and cell surface staining
    Zelnickova, Petra
    Faldyna, Martin
    Stepanova, Hana
    Ondracek, Jaroslav
    Kovaru, Frantisek
    JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 327 (1-2) : 18 - 29
  • [46] Laser pointer visual field screening
    Lee, MS
    Balcer, LJ
    Volpe, NJ
    Liu, GT
    Ying, GS
    Galetta, SL
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2003, 23 (04) : 260 - 263
  • [47] AOA issues laser pointer warnings
    不详
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (07) : 439 - 439
  • [48] 6 markers/5 colors extended white blood cell differential by flow cytornetry
    Faucher, Jean-Luc
    Lacronique-Gazaille, Charlotte
    Frebet, Elise
    Trimoreau, Franck
    Donnard, Magali
    Bordessoule, Dominique
    Lacombe, Francis
    Feuillard, Jean
    CYTOMETRY PART A, 2007, 71A (11) : 934 - 944
  • [49] A laser pointer/laser trails tracking system for visual performance
    Fukuchi, K
    HUMAN-COMPUTER INTERACTION - INTERACT 2005, PROCEEDINGS, 2005, 3585 : 1050 - 1053
  • [50] Generation and Evaluation of an Efficient Femtosecond Green Laser
    Teng, Mingyang
    Meng, Xianghao
    SENSORS, 2024, 24 (16)