Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics

被引:6
|
作者
Karahan, Mehmet [1 ]
Kocabeyoglu, Sinan Sabit [1 ]
Kervan, Umit [1 ]
Sert, Dogan Emre [1 ]
Aygun, Emre [1 ]
Tola, Muharrem [2 ]
Demirkan, Burcu [3 ]
Mungan, Semra [4 ]
Kursun, Oguzhan [4 ]
Catav, Zeki [1 ]
Pac, Mustafa [1 ]
机构
[1] Turkiye Yuksek Ihtisas Hosp, Cardiovasc Surg, Kizilay St 4 Altindag, TR-06100 Ankara, Turkey
[2] Turkiye Yuksek Ihtisas Hosp, Radiol, Ankara, Turkey
[3] Turkiye Yuksek Ihtisas Hosp, Cardiol, Ankara, Turkey
[4] Ankara Numune Hosp, Neurol, Ankara, Turkey
关键词
carotid artery; middle cerebral artery; pulsatility index; resistive index; ventricular assist device; ADVANCED HEART-FAILURE; BLOOD-FLOW; CAROTID CIRCULATION; RESISTIVE INDEX; ISCHEMIC-STROKE; VELOCITY; AUTOREGULATION; RESISTANCE; ARTERIES;
D O I
10.1111/aor.13616
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an organ is perfused sufficiently. The aim of this study is to evaluate and identify the flow pattern changes of carotid (CA) and middle cerebral arteries (MCA) in LVAD patients and to compare with heart failure patients and healthy volunteers. Eighty-nine individuals were included in this cross-sectional study. Participants were divided into three groups: LVAD patients (n = 31), heart failure patients (n = 26), and healthy volunteers (n = 27). Carotid and transcranial Doppler ultrasonography were performed for all study groups for peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility (PI), and resistive (RI) indices of CA and MCA. Flow dynamics were compared between the groups. Doppler ultrasonographic data were analyzed at a median 12 (3-47) months after LVAD implantation. CA-PSV was lower in LVAD group compared with the other two groups (P < .001), MCA-PSV of LVAD and heart failure groups were similar and lower than healthy volunteers (P < .05). The highest values for CA-EDV were found in the LVAD group (P < .05). MCA-EDV values were found to be lowest in heart failure group (P < .05). For PI and RI, in all CA and MCA, the LVAD group had lower indices compared with the other two groups (P < .001). In addition, MCA flow analysis in patients with LVADs was identified for the first time with this study.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 50 条
  • [21] Echocardiography and Continuous-Flow Left Ventricular Assist Devices Evidence and Limitations
    Cohen, David G.
    Thomas, James D.
    Freed, Benjamin H.
    Rich, Jonathan D.
    Sauer, Andrew J.
    JACC-HEART FAILURE, 2015, 3 (07) : 554 - 564
  • [22] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Pouya Tahsili-Fahadan
    David R. Curfman
    Albert A. Davis
    Noushin Yahyavi-Firouz-Abadi
    Lucia Rivera-Lara
    Michael E. Nassif
    Shane J. LaRue
    Gregory A. Ewald
    Allyson R. Zazulia
    Neurocritical Care, 2018, 29 : 225 - 232
  • [23] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Tahsili-Fahadan, Pouya
    Curfman, David R.
    Davis, Albert A.
    Yahyavi-Firouz-Abadi, Noushin
    Rivera-Lara, Lucia
    Nassif, Michael E.
    LaRue, Shane J.
    Ewald, Gregory A.
    Zazulia, Allyson R.
    NEUROCRITICAL CARE, 2018, 29 (02) : 225 - 232
  • [24] Characteristics of the Electrocardiogram in Patients with Continuous-Flow Left Ventricular Assist Devices
    Martinez, Sara C.
    Fansler, Derrick
    Lau, Jeffrey
    Novak, Eric L.
    Joseph, Susan M.
    Kleiger, Robert E.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (01) : 62 - 68
  • [25] Transthoracic Echocardiographic Assessment of Continuous-Flow Left Ventricular Assist Devices
    Rasalingam, Ravi
    Johnson, Stephanie N.
    Bilhorn, Kyle R.
    Huang, Pei-Hsiu
    Makan, Majesh
    Moazami, Nader
    Perez, Julio E.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (02) : 135 - 148
  • [26] Endocrine Challenges in Patients with Continuous-Flow Left Ventricular Assist Devices
    Martucci, Gennaro
    Pappalardo, Federico
    Subramanian, Harikesh
    Ingoglia, Giulia
    Conoscenti, Elena
    Arcadipane, Antonio
    NUTRIENTS, 2021, 13 (03) : 1 - 17
  • [27] COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES
    Neyt, Mattias
    Van den Bruel, Ann
    Smit, Yolba
    De Jonge, Nicolaas
    Erasmus, Michiel
    Van Dijk, Diederik
    Vlayen, Joan
    INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2013, 29 (03) : 254 - 260
  • [28] Durability of continuous-flow left ventricular assist devices: a systematic review
    Xie, Ashleigh
    Phan, Kevin
    Yan, Tristan D.
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (06) : 547 - 556
  • [29] Continuous-Flow Left Ventricular Assist Device
    Landzaat, Lindy H.
    Sinclair, Christian T.
    Rosielle, Drew A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1149 - 1149
  • [30] The risk of right ventricular failure with current continuous-flow left ventricular assist devices
    Loforte, Antonio
    Grigioni, Francesco
    Marinelli, Giuseppe
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (12) : 969 - 983