Exergy analysis of a hybrid ground-source heat pump system

被引:50
|
作者
Menberg, Kathrin [1 ,2 ]
Heo, Yeonsook [2 ]
Choi, Wonjun [3 ]
Ooka, Ryozo [3 ]
Choudhary, Ruchi [1 ]
Shukuya, Masanori [4 ]
机构
[1] Univ Cambridge, Dept Engn, Trumpington St, Cambridge, England
[2] Univ Cambridge, Dept Architecture, 1-5 Scroope Terrace, Cambridge, England
[3] Univ Tokyo, Inst Ind Sci, Meguro Ku, 4-6-1 Komaba, Tokyo, Japan
[4] Tokyo City Univ, Dept Restorat Ecol & Built Environm, Tokyo, Japan
基金
英国工程与自然科学研究理事会;
关键词
Energy analysis; Ground source heat pump systems; Hybrid systems; AIR-CONDITIONING SYSTEM; THERMODYNAMIC ANALYSIS; THEORETICAL-ANALYSIS; POWER-PLANT; ENERGY; PERFORMANCE; SUSTAINABILITY; BUILDINGS; OPERATION; INDUSTRY;
D O I
10.1016/j.apenergy.2017.06.076
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In contrast to energy analysis, the analysis of energy allows the evaluation of the quality of different energy flows and enables a comprehensive assessment of inefficiencies within a system and its individual components by accounting for exergy consumption. While exergy analysis methods have been applied to a variety of conventional and renewable energy supply systems, there is still a lack of knowledge regarding the exergy flows and exergy efficiency of hybrid ground-source heat pump systems with a supplementary boiler. In this study, we develop a thermodynamic model for each subsystem in a hybrid heating and cooling system of an existing building by applying the concept of cool and warm exergy. A comparison of the exergy consumption of the hybrid system in heating and cooling reveals that there are significant differences regarding the components that attribute most to the overall exergy consumption in the system. Due to these differences the true exergy performance of the system in heating mode (similar to 30%) is twice as high as for cooling mode (similar to 15%), while the natural exergy performance is considerably better in cooling mode (similar to 26% to similar to 3%). Potential measures to enhance the exergy performance based on changes in the operational settings of the system and the improvement of the building envelope were found to have a more significant effect on heating performance than on cooling performance. In general, measures that affect the amount of thermal energy delivered by the system appear to be more effective than changes to the operational settings of energy supply systems. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:31 / 46
页数:16
相关论文
共 50 条
  • [21] The utilization of ground-source heat pump system in East China
    Cheng, Heng-Sheng
    Gong, Wei-Sheng
    Liu, Xiang-Long
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 27 - 30
  • [22] Simulation Tool for Ground-Source Heat Pump System with Multiple Ground Heat Exchangers
    Katsura, Tako
    Nagano, Katsunori
    ASHRAE TRANSACTIONS 2018, VOL 124, PT 2, 2018, 124 : 92 - 101
  • [23] Dynamic thermal analysis of a residential ground-source heat pump
    Yang, S.
    Lee, S. B.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37
  • [24] GROUND-SOURCE HEAT-PUMP SYSTEMS
    CALM, J
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59
  • [25] Performance study of a novel hybrid solar PV/T ground-source heat pump system
    Cai, Junjie
    Quan, Zhenhua
    Li, Tianyao
    Hou, Longshu
    Zhao, Yaohua
    Yao, Mengliang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1642 - 1649
  • [26] Optimal control of cooling tower in hybrid ground-source heat pump system for hotel buildings
    Wang, Lingyun
    Zhang, Jialuo
    Min, Heng
    Xu, Linghong
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 1749 - 1756
  • [27] Exergy and energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions
    Ally, Moonis R.
    Munk, Jeffrey D.
    Baxter, Van D.
    Gehl, Anthony C.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2013, 36 (05) : 1417 - 1430
  • [28] RESEARCH AND APPLICATION OF SOLAR-ASSISTED GROUND-SOURCE HEAT PUMP HYBRID SYSTEM IN CHINA
    Gong, Xue-Mei
    ENERGY AND MECHANICAL ENGINEERING, 2016, : 227 - 237
  • [29] Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system
    Ozgener, O
    Hepbasli, A
    APPLIED THERMAL ENGINEERING, 2005, 25 (10) : 1459 - 1471
  • [30] An analysis of the factors affecting hybrid ground-source heat pump installation potential in North America
    Nguyen, Hiep V.
    Law, Ying Lam E.
    Alavy, Masih
    Walsh, Philip R.
    Leong, Wey H.
    Dworkin, Seth B.
    APPLIED ENERGY, 2014, 125 : 28 - 38