Using a thermal manikin to determine evaporative resistance and thermal insulation - A comparison of methods

被引:4
|
作者
Toma, Robert [1 ]
Kuklane, Kalev [2 ]
Fojtlin, Milos [3 ]
Fiser, Jan [1 ]
Jicha, Miroslav [1 ]
机构
[1] Brno Univ Technol, Fac Mech Engn, Brno 61669, Czech Republic
[2] Inst Safety IKV, Zoetermeer, Netherlands
[3] Brno Univ Technol, Energy Inst, Tech 2, Brno, Czech Republic
关键词
Evaporative resistance; thermal manikin; resultant thermal insulation; protective clothing; LOCAL CLOTHING PROPERTIES; HUMAN THERMOREGULATION; HEAT-STRESS; MODEL; RISK; SKIN;
D O I
10.1177/1528083719900672
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Heat transfer from the human body, especially through the evaporation of sweat from the skin, is often restricted when protective clothing is used, which may result in overheating. For this reason, it is important to consider the parameters of protective clothing as input data in physiological models, such as predicted heat strain. The two most important parameters are thermal insulation and evaporative resistance with clothing area factor strongly influencing both. These parameters were determined for two clothing ensembles using a (dry) non-sweating thermal manikin. First, the clothing area factor was determined using the photographic method. Second, thermal insulation was measured in both static and dynamic conditions, and multiple equations for predicting dynamic thermal insulation from static ones were evaluated. Third, methodology for measuring evaporative resistance based on pre-wetted skin was adopted and multiple corrections were assessed. Finally, sensitivity analyses were completed using PHS to determine the impact of different equations on the duration limited exposure. For the thermal insulation measurements, we found that predictive equation (32) from ISO 9920 was the most accurate, but choosing the correct equation for protective clothing proved challenging. Although a manikin's surface temperature is widely used for calculating evaporative resistance, the skin temperature should be used instead, since it is correct from a physical point of view and there is a difference of up to 15% in the results. Because these measures are used in thermal risk analyses conditions, a high degree of accuracy and a knowledge of the inputs must be guaranteed.
引用
收藏
页码:1493 / 1515
页数:23
相关论文
共 50 条
  • [21] Correction of the evaporative resistance of clothing by the temperature of skin fabric on a sweating and walking thermal manikin
    Ueno, Satoru
    Sawada, Shin-ichi
    TEXTILE RESEARCH JOURNAL, 2012, 82 (11) : 1143 - 1156
  • [22] A comparison of apparatus used to measure thermal insulation properties to determine thermal comfort
    Zhang Yun
    Wu Zi-ying
    Ji Er-li
    Zhou Xiao-hong
    Chen Jian-Yong
    THERMAL MANIKINS AND MODELLING, 2006, : 313 - +
  • [23] Comparative evaluation of clothing thermal insulation measured in a thermal manikin and on volunteers
    Central Institute for Labour Protection, National Research Institute, Department of Ergonomy, ul. Czemiakowska 16, 00-701 Warsaw, Poland
    Fibres Text. East. Eur., 2007, 2 (73-79): : 73 - 79
  • [24] Comparative evaluation of clothing thermal insulation measured on a thermal manikin and on volunteers
    Konarska, Maria
    Soltynski, Krzysztof
    Sudol-Szopinska, Iwona
    Chojnacka, Anna
    FIBRES & TEXTILES IN EASTERN EUROPE, 2007, 15 (02) : 73 - 79
  • [25] Guidelines for measuring thermal resistance on thermal Foot Manikin
    Aboalasaad, Abdelhamid R. R.
    Sirkova, Brigita K.
    Tesinova, Pavla
    Khalil, Amany
    MATERIALS TODAY-PROCEEDINGS, 2020, 31 : S232 - S235
  • [26] Comments on "Correction of the evaporative resistance of clothing by the temperature of skin fabric on a sweating and walking thermal manikin"
    Wang, Faming
    Kuklane, Kalev
    TEXTILE RESEARCH JOURNAL, 2012, 82 (17) : 1827 - 1829
  • [27] Investigation of cleanroom clothing thermal insulation by thermal manikin and impact on thermal comfort of cleanroom users
    Konecna, Katerina
    Adamovsky, Daniel
    JOURNAL OF INDUSTRIAL TEXTILES, 2025, 55
  • [28] Measurements of clothing insulation with a thermal manikin operating under the thermal comfort regulation mode: comparative analysis of the calculation methods
    Oliveira, A. Virgilio M.
    Gaspar, Adelio R.
    Quintela, Divo A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (04) : 679 - 688
  • [29] Measurements of clothing insulation with a thermal manikin operating under the thermal comfort regulation mode: comparative analysis of the calculation methods
    A. Virgílio M. Oliveira
    Adélio R. Gaspar
    Divo A. Quintela
    European Journal of Applied Physiology, 2008, 104 : 679 - 688
  • [30] A comparison of methods for measuring thermal insulation of military clothing
    Svecova, Jana
    Strohmandl, Jan
    Fiser, Jan
    Toma, Robert
    Hajna, Petr
    Havelka, Antonin
    JOURNAL OF INDUSTRIAL TEXTILES, 2021, 51 (04) : 632 - 648