Measurement of exposure buildup factors: The influence of scattered photons on gamma-ray attenuation coefficients

被引:14
|
作者
Mann, Kulwinder Singh [1 ]
机构
[1] DAV Coll, Dept Phys, Bathinda 151001, Punjab, India
关键词
Exposure buildup factor; Gamma-ray measurement; Optimum optical thickness; THICKNESS; SAMPLES;
D O I
10.1016/j.nima.2017.08.047
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Scattered photon's influence on measured values of attenuation coefficients (mu(m), cm(2)g(-1)) for six low-Z (effective atomic number) building materials, at three photon energies has been estimated. Narrow-beam transmission geometry has been used for the measurements. Samples of commonly used engineering materials (Cements, Clay, Lime-Stone, Plaster of Paris) have been selected for the present study. Standard radioactive sources Cs-137 and Co-60 have been used for obtaining gamma-ray energies 661.66, 1173.24 and 1332.50 keV. The optical thickness (OT) of 0.5 mfp (mean free path) has been found the optimum optical thickness (OOT) for mu(m)-measurement in the selected energy range (661.66-1332.50 keV). The aim of this investigation is to provide neglected information regarding subsistence of scattered photons in narrow beam geometry measurements for low-Z materials. The measurements have been performed for a wide range of sample-thickness (2-26 cm) such that their OT varies between 0.2-3.5 mfp in selected energy range. A computer program (GRIC2-toolkit) has been used for various theoretical computations required in this investigation. It has been concluded that in selected energy-range, good accuracy in mu(m)-measurement of low-Z materials can be achieved by keeping their sample's OT below 0.5 mfp. The exposure buildup factors have been measured with the help of mathematical-model developed in this investigation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] GAMMA-RAY BUILDUP FACTORS FOR FINITE CYLINDRICAL MEDIA
    ELIAS, E
    SEGAL, Y
    NOTEA, A
    NUCLEAR INSTRUMENTS & METHODS, 1975, 131 (02): : 307 - 314
  • [22] SIGNIFICANT DIFFERENCES IN REPORTED GAMMA-RAY BUILDUP FACTORS
    NATARAJAN, A
    SUBBAIAH, KV
    GOPINATH, DV
    NUCLEAR SCIENCE AND ENGINEERING, 1983, 85 (04) : 418 - 422
  • [23] POINT ISOTROPIC GAMMA-RAY BUILDUP FACTORS IN CONCRETE
    EISENHAUER, CM
    SIMMONS, GL
    NUCLEAR SCIENCE AND ENGINEERING, 1975, 56 (03) : 263 - 270
  • [24] Evaluation of gamma-ray exposure buildup factors and neutron shielding for bismuth borosilicate glasses
    Singh, Vishwanath P.
    Badiger, N. M.
    Chanthima, N.
    Kaewkhao, J.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 98 : 14 - 21
  • [25] Effects of the photon cross sections and energy-absorption coefficients of air to the gamma-ray point isotropic exposure buildup factors
    Hirayama, H
    NUCLEAR SCIENCE AND ENGINEERING, 1996, 124 (02) : 258 - 270
  • [26] Gamma-ray attenuation coefficients in bismuth borate glasses
    Singh, K
    Singh, H
    Sharma, V
    Nathuram, R
    Khanna, A
    Kumar, R
    Bhatti, SS
    Sahota, HS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 194 (01): : 1 - 6
  • [27] GAMMA-RAY ATTENUATION COEFFICIENTS FOR HIGHER GREEN PLANTS
    TSOULFANIDIS, N
    HEALTH PHYSICS, 1974, 27 (01): : 145 - 147
  • [28] EFFECTIVE GAMMA-RAY ATTENUATION COEFFICIENTS FOR RADIOACTIVE ORES
    NOVIKOV, GF
    SINITSYN, AY
    KOZYNDA, YO
    SOVIET ATOMIC ENERGY, 1976, 40 (02): : 206 - 207
  • [29] MEASUREMENTS OF GAMMA-RAY ATTENUATION COEFFICIENTS OF ORGANIC SCINTILLATORS
    GOSWAMI, B
    CHAUDHURI, N
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (02): : 317 - 318
  • [30] GAMMA-RAY ANGULAR CORRELATION ATTENUATION FACTORS
    HERSKIND, B
    YOSHIZAWA, Y
    NUCLEAR INSTRUMENTS & METHODS, 1964, 27 (01): : 104 - 108