Performance characteristics and parametric optimization of an irreversible magnetic Ericsson heat-pump

被引:4
|
作者
Wei, Fang [1 ,2 ]
Lin, Guoxing [1 ,2 ]
Chen, Jincan [1 ,2 ]
Bruck, Ekkes [3 ]
机构
[1] Xiamen Univ, Dept Phys, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Inst Theoret Phys & Astrophys, Xiamen 361005, Peoples R China
[3] Delft Univ Technol, Fac Sci Appl, NL-2629 JB Delft, Netherlands
关键词
Magnetic material; Heat pump; Irreversibility; Optimal performance; THERMOECONOMIC OPTIMIZATION; REFRIGERATOR;
D O I
10.1016/j.physb.2010.11.067
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Taking into account the finite-rate heat transfer in the heat-transfer processes, heat leak between the two external heat reservoirs, regenerative loss, regeneration time, and internal irreversibility due to dissipation of the cycle working substance, an irreversible magnetic Ericsson heat-pump cycle is presented. On the basis of the thermodynamic properties of magnetic materials, the performance characteristics of the irreversible magnetic Ericsson heat-pump are investigated and the relationship between the optimal heating load and the coefficient of performance (COP) is derived. Moreover, the maximum heating load and the corresponding COP as well as the maximum COP and the corresponding heating load are obtained. Furthermore, the other optimal performance characteristics are discussed in detail. The results obtained here may provide some new information for the optimal parameter design and the development of real magnetic Ericsson heat-pumps. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 50 条
  • [21] PERFORMANCE-CHARACTERISTICS OF A DRYING HEAT-PUMP USING SUPERHEATED STEAM
    MORAITIS, CS
    AKRITIDIS, CB
    DRYING TECHNOLOGY, 1995, 13 (1-2) : 319 - 332
  • [22] STATIC CHARACTERISTICS OF A DISTILLATION SYSTEM WITH A HEAT-PUMP
    TAKIYAMA, H
    NAKA, Y
    OSHIMA, E
    YAMAMOTO, T
    KAGAKU KOGAKU RONBUNSHU, 1991, 17 (01) : 157 - 165
  • [23] EFFECTS OF REVERSING VALVES ON HEAT-PUMP PERFORMANCE
    DAMASCENO, G
    ROOKE, S
    GOLDSCHMIDT, VW
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (02): : 93 - 97
  • [24] PERFORMANCE OF A HEAT-PUMP WITH A DIGITAL EXPANSION VALVE
    GUIGUEMDE, R
    HABERSCHILL, P
    LALLEMAND, M
    REVUE GENERALE DE THERMIQUE, 1990, 29 (347): : 644 - 649
  • [25] PERFORMANCE OF A SOLAR ASSISTED HEAT-PUMP SYSTEM
    EGRICAN, AN
    ENERGY CONVERSION AND MANAGEMENT, 1991, 31 (01) : 17 - 25
  • [26] ICE-MAKER HEAT-PUMP PERFORMANCE
    DORGAN, CE
    SHARP, WF
    NELSON, GC
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1982, 24 (09): : 29 - 32
  • [27] COEFFICIENT OF PERFORMANCE FOR FINITE SPEED HEAT-PUMP
    BLANCHARD, CH
    JOURNAL OF APPLIED PHYSICS, 1980, 51 (05) : 2471 - 2472
  • [28] HEAT-PUMP PERFORMANCE CALCULATION USING A MICROCOMPUTER
    LAZARIDIS, A
    ENGINEERING EXCELLENCE : PEOPLE MAKE THE DIFFERENCE, VOLS 1-3, 1989, : 794 - 796
  • [29] VARIABLE SPEED DRIVE HEAT-PUMP PERFORMANCE
    JETER, SM
    WEPFER, WJ
    FADEL, GM
    COWDEN, NE
    DYMEK, AA
    ENERGY, 1987, 12 (12) : 1289 - 1298
  • [30] PERFORMANCE ANALYSIS OF AN EFFICIENT EXHAUST HEAT-PUMP
    SAMI, SM
    LAPLANTE, G
    HEAT RECOVERY SYSTEMS & CHP, 1992, 12 (04): : 289 - 302