Performance characteristics and parametric optimization of an irreversible magnetic Ericsson heat-pump

被引:4
|
作者
Wei, Fang [1 ,2 ]
Lin, Guoxing [1 ,2 ]
Chen, Jincan [1 ,2 ]
Bruck, Ekkes [3 ]
机构
[1] Xiamen Univ, Dept Phys, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Inst Theoret Phys & Astrophys, Xiamen 361005, Peoples R China
[3] Delft Univ Technol, Fac Sci Appl, NL-2629 JB Delft, Netherlands
关键词
Magnetic material; Heat pump; Irreversibility; Optimal performance; THERMOECONOMIC OPTIMIZATION; REFRIGERATOR;
D O I
10.1016/j.physb.2010.11.067
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Taking into account the finite-rate heat transfer in the heat-transfer processes, heat leak between the two external heat reservoirs, regenerative loss, regeneration time, and internal irreversibility due to dissipation of the cycle working substance, an irreversible magnetic Ericsson heat-pump cycle is presented. On the basis of the thermodynamic properties of magnetic materials, the performance characteristics of the irreversible magnetic Ericsson heat-pump are investigated and the relationship between the optimal heating load and the coefficient of performance (COP) is derived. Moreover, the maximum heating load and the corresponding COP as well as the maximum COP and the corresponding heating load are obtained. Furthermore, the other optimal performance characteristics are discussed in detail. The results obtained here may provide some new information for the optimal parameter design and the development of real magnetic Ericsson heat-pumps. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 50 条
  • [1] Parametric optimization of an irreversible magnetic Ericsson refrigerator with finite heat reservoirs
    Ye, X. M.
    Lin, G. X.
    Chen, J. C.
    Bruck, E.
    PHYSICA B-CONDENSED MATTER, 2007, 391 (02) : 350 - 356
  • [2] Optimization of the performance characteristics in an irreversible magnetic Ericsson refrigeration cycle
    Xia, Z. R.
    Ye, X. M.
    Lin, G. X.
    Bruck, E.
    PHYSICA B-CONDENSED MATTER, 2006, 381 (1-2) : 246 - 255
  • [3] The performance of irreversible combined heat-pump cycles
    Goktun, S
    Yavuz, H
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (20) : 2848 - 2852
  • [4] Performance evaluation of irreversible Stirling and Ericsson heat pump cycles
    Kaushik, SC
    Tyagi, SK
    Bose, SK
    Singhal, MK
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (02) : 193 - 200
  • [5] Irreversible absorption heat-pump and its optimal performance
    Chen, LG
    Qin, XY
    Sun, FR
    Wu, C
    APPLIED ENERGY, 2005, 81 (01) : 55 - 71
  • [6] Ecological optimization and parametric study of irreversible Stirling and Ericsson heat pumps
    Tyagi, SK
    Kaushik, SC
    Salohtra, R
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (16) : 2058 - 2065
  • [7] Performance optimization of an irreversible heat pump
    Cheng, CY
    Chen, CK
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (12) : 2451 - 2454
  • [8] Parametric analysis on the performance of a revolutionary rotary Ericsson heat pump/engine
    Zhang, Wenbin
    Benson, Chris
    Cunningham, Andrew
    Riffat, Saffa
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (01) : 36 - 43
  • [9] Ecological optimization and performance study of irreversible Stirling and Ericsson heat engines
    Tyagi, SK
    Kaushik, SC
    Salhotra, R
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (20) : 2668 - 2675
  • [10] Heat-pump drying characteristics and process optimization of cowpea
    Zhang, Bo
    Ji, Changying
    Torotwa, Ian
    Memon, Muhammad Sohail
    Xu, Weiyue
    Song, Zhen
    Cheng, Hui
    International Agricultural Engineering Journal, 2018, (04): : 337 - 348