Accuracy and primary stability of tapered or straight implants placed into fresh extraction socket using dynamic navigation: a randomized controlled clinical trial

被引:26
|
作者
Wei, Shi-Min
Shi, Jun-Yu
Qiao, Shi-Chong
Zhang, Xiao
Lai, Hong-Chang [1 ]
Zhang, Xiao-Meng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med,Natl Clin Res Ctr Oral Dis,Shanghai Lab S, Coll Stomatol,Dept Oral & Maxillofacial Implantol, Shanghai, Peoples R China
关键词
Dental implants; Dynamic navigation; Immediate implant placement; Tapered implant; Straight implant; IMMEDIATE; FAILURES;
D O I
10.1007/s00784-021-04247-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To compare the accuracy and primary stability of tapered and straight implants undergoing immediate implant placement with dynamic navigation. Materials and methods Patients with compromised anterior teeth in maxilla were recruited and allocated randomly into (1) tapered implant group (TI group) and (2) straight implant group (SI group). Implants were inserted into fresh sockets with dynamic navigation. Three-dimensional platform deviation, apex deviation, angular deviation, insertion torque value (ITV) and implant stability quotient (ISQ) were recorded. Results Twenty patients with 20 implants were included. The overall platform, apex, and angular deviation were 0.87 +/- 0.35 mm, 0.81 +/- 0.34 mm, and 2.40 +/- 1.31 degrees, respectively. The accuracy was 0.86 +/- 0.26 mm, 0.76 +/- 0.33 mm, and 2.49 +/- 1.54 degrees for TI, and 0.89 +/- 0.44 mm, 0.88 +/- 0.36 mm, and 2.31 +/- 1.01 degrees for SI, with no significant difference (p = 0.85, 0.45, 0.76). Sagittal root position classification (SRP) class I may obtain greater error in numerical values in straight implants (0.97 +/- 0.47 mm vs. 0.6 +/- 0.16 mm, 0.92 +/- 0.36 mm vs. 0.73 +/- 0.36 mm, 2.48 +/- 1.19 degrees vs. 1.71 +/- 0.14 degrees). The overall ISQ was 60.74. ISQ was 60.48 for TI and 60.96 for SI, with no significant difference. Acceptable ITV (> 15 Ncm) was achieved in most of the included patients (SI 7/10, TI 9/10). Conclusions High accuracy and primary stability of immediate implant placement could be achieved both in tapered and straight implants with dynamic navigation systems.
引用
收藏
页码:2733 / 2741
页数:9
相关论文
共 50 条
  • [41] Esthetic, clinical and patient-centered outcomes of immediately placed implants (Type 1) and early placed implants (Type 2): preliminary 3-month results of an ongoing randomized controlled clinical trial
    Huynh-Ba, Guy
    Meister, David J.
    Hoders, Ashley B.
    Mealey, Brian L.
    Mills, Michael P.
    Oates, Thomas W.
    Cochran, David L.
    Prihoda, Thomas J.
    McMahan, C. Alex
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 241 - 252
  • [42] Placement accuracy and primary stability of implants in the esthetic zone using dynamic and static computer-assisted navigation: A retrospective case-control study
    Liu, Quan
    Liu, Yuanxiang
    Chen, Danying
    Wu, Xiayi
    Huang, Ruoxuan
    Liu, Runheng
    Chen, Zetao
    Chen, Zhuofan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 427 - 435
  • [43] Immediate Functional Loading of Implants Placed with Flapless Surgery Versus Conventional Implants in Partially Edentulous Patients: A 3-Year Randomized Controlled Clinical Trial
    Cannizzaro, Gioacchino
    Leone, Michele
    Consolo, Ugo
    Ferri, Vittorio
    Esposito, Marco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (05) : 867 - 875
  • [44] Immediate Functional Loading of Implants Placed with Flapless Surgery Versus Conventional Implants in Partially Edentulous Patients - A 3-Year Randomized Controlled Clinical Trial
    Cannizzaro, Gioacchino
    Leone, Michele
    Consolo, Ugo
    Ferri, Vittorio
    Esposito, Marco
    IMPLANTOLOGIE, 2008, 16 (04): : 391 - 402
  • [45] Socket Preservation Using Bovine Bone Mineral and Collagen Membrane: A Randomized Controlled Clinical Trial with Histologic Analysis
    Cardaropoli, Daniele
    Tamagnone, Lorenzo
    Roffredo, Alessandro
    Gaveglio, Lorena
    Cardaropoli, Giuseppe
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2012, 32 (04) : 421 - 430
  • [46] Comparative Evaluation of the Accuracy of Dynamic Navigation and Free Hand Methods During Zygomatic Implant Placement: A Randomized Controlled Trial
    Penmetsa, Gautami S.
    Shah, Rahul Manhar
    Raju, M. A. K. V.
    Gadde, Praveen
    Venkata, Ramaraju Alluri
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (05) : 468 - 473
  • [47] Impact of fully or partially guided surgery on the position of single implants immediately placed in maxillary incisor sockets: A randomized controlled clinical trial
    Kraft, Bruno
    Frizzera, Fausto
    de Freitas, Rubens Moreno
    de Oliveira, Guilherme Jose Lopes Pimentel
    Marcantonio Junior, Elcio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (05) : 631 - 637
  • [48] Aesthetic outcomes of different materials for delayed, single-tooth restorations for immediately placed implants. A randomized controlled clinical trial
    Zamora, Guillermo Pardo
    Molina-Gonzalez, Juan Manuel
    Martinez-Marco, Jose Francisco
    Ruiz, Antonio Jose Ortiz
    Mardas, Nikos
    Garcia-Sanchez, Ruben
    JOURNAL OF DENTISTRY, 2024, 146
  • [49] Clinical and Radiographic Evaluation of Marginal Bone Changes around Platform-Switching Implants Placed in Crestal or Subcrestal Positions: A Randomized Controlled Clinical Trial
    Kutan, Esma
    Bolukbasi, Nilufer
    Yildirim-Ondur, Esra
    Ozdemir, Tayfun
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E364 - E375
  • [50] Multicenter Clinical Randomized Controlled Trial Evaluation of an Implant System Designed for Enhanced Primary Stability
    Stanford, Clark M.
    Barwacz, Chris
    Raes, Stephanie
    De Bruyn, Hugo
    Cecchinato, Denis
    Bittner, Nurit
    Brandt, Jan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : 906 - 915