Sol-Gel Deposition of Iridium Oxide for Biomedical Micro-Devices

被引:34
|
作者
Nguyen, Cuong M. [1 ]
Rao, Smitha [1 ]
Yang, Xuesong [1 ]
Dubey, Souvik [1 ]
Mays, Jeffrey [1 ]
Cao, Hung [2 ]
Chiao, Jung-Chih [1 ]
机构
[1] Univ Texas Arlington, Dept Elect Engn, Arlington, TX 76019 USA
[2] ETS, Dept Elect Engn, Montreal, PQ H3C 1K3, Canada
来源
SENSORS | 2015年 / 15卷 / 02期
关键词
REFERENCE ELECTRODES; NEURAL STIMULATION; CHARGE-INJECTION; AMPEROMETRIC DETERMINATION; IN-VITRO; GLUTAMATE; SENSOR; DOPAMINE; FILMS; NEUROTRANSMITTERS;
D O I
10.3390/s150204212
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabrication method yields reliable miniature on-probe IrOx electrodes with long lifetime, high stability and repeatability. Such sensors can be used for long-term measurements. Various dimensions of sol-gel iridium oxide electrodes including 1 mm x 1 mm, 500 mu m x 500 mu m, and 100 mu m x 100 mu m were fabricated. Sensor longevity and pH dependence were investigated by immersing the electrodes in hydrochloric acid, fetal bovine serum (FBS), and sodium hydroxide solutions for 30 days. Less pH dependent responses, compared to IrOx electrodes fabricated by electrochemical deposition processes, were measured at 58.8 +/- 0.4 mV/pH, 53.8 +/- 1.3 mV/pH and 48 +/- 0.6 mV/pH, respectively. The on-probe IrOx pseudo-reference electrodes were utilized for dopamine sensing. The baseline responses of the sensors were higher than the one using an external Ag/AgCl reference electrode. Using IrOx reference electrodes integrated on the same probe with working electrodes eliminated the use of cytotoxic Ag/AgCl reference electrode without loss in sensitivity. This enables employing such sensors in long-term recording of concentrations of neurotransmitters in central nervous systems of animals and humans.
引用
收藏
页码:4212 / 4228
页数:17
相关论文
共 50 条
  • [21] Photocatalytic properties of titanium oxide coating prepared by electrophoretic sol-gel deposition
    Kurosaki, T
    Nakagawa, A
    Iimura, S
    Yoshihara, S
    Shirakashi, T
    ELECTROCHEMISTRY, 2002, 70 (11) : 860 - 862
  • [22] Sol-Gel Preparation, Deposition and Characterization of Nanostructured Aluminium Doped Zinc Oxide
    Ganesh, T.
    Rajesh, S.
    Xavier, Francis P.
    JOURNAL OF NANO RESEARCH, 2013, 24 : 96 - 106
  • [23] Sol-gel methods for oxide coatings
    Francis, LF
    MATERIALS AND MANUFACTURING PROCESSES, 1997, 12 (06) : 963 - 1015
  • [24] Sol-gel synthesis of oxide materials
    Livage, J
    Beteille, F
    Roux, C
    Chatry, M
    Davidson, P
    ACTA MATERIALIA, 1998, 46 (03) : 743 - 750
  • [25] One Step Deposition of Sol-Gel Carbon Nanotubes Biocomposite for Reagentless Electrochemical Devices
    Urbanova, Veronika
    Etienne, Mathieu
    Walcarius, Alain
    ELECTROANALYSIS, 2013, 25 (01) : 85 - 93
  • [26] Sol-Gel Iridium Oxide-Based pH Sensor Array on Flexible Polyimide Substrate
    Nguyen, Cuong M.
    Huang, Wen-Ding
    Rao, Smitha
    Cao, Hung
    Tata, Uday
    Chiao, Mu
    Chiao, Jung-Chih
    IEEE SENSORS JOURNAL, 2013, 13 (10) : 3857 - 3864
  • [27] Sol-gel technologies for multimode waveguide devices
    Karioja, P
    Kusevic, M
    Hiltunen, M
    Paaso, J
    Mäkinen, JT
    Hiltunen, J
    Kautio, K
    Kopola, H
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES VI, 2002, 4640 : 46 - 53
  • [28] Sol-gel electrophoretic deposition of PZT nanotubes
    Nourmohammadi, A.
    Bahrevar, M. A.
    Hietschold, M.
    MATERIALS LETTERS, 2008, 62 (19) : 3349 - 3351
  • [29] Selective Deposition of Biocompatible Sol-Gel Materials
    T.M. Harrell
    B. Hosticka
    M.E. Power
    L. Cemke
    R. Hull
    P.M. Norris
    Journal of Sol-Gel Science and Technology, 2004, 31 : 349 - 352
  • [30] Selective deposition of biocompatible sol-gel materials
    Harrell, TM
    Hosticka, B
    Power, ME
    Cemke, L
    Hull, R
    Norris, PM
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2004, 31 (1-3) : 349 - 352