Comparison of Different Fixation Types Used in Unilateral Mandibular Condylar Fractures: An In Vivo Study With New Biomechanical Model

被引:8
|
作者
Cimen, Emre
Onder, Mustafa Ercument [1 ]
Cambazoglu, Mine [2 ]
Birant, Emir [3 ]
机构
[1] Kirikkale Univ, Dept OMFS, Fac Dent, Kirikkale, Turkey
[2] Ankara Univ, Fac Dent, Dept OMFS, Ankara, Turkey
[3] Birant Makina, Ankara, Turkey
关键词
Biomechanical test; condylar fracture; double mini plate fixation; resorbable plate fixation; single-titanium mini plate fixation; CLOSED TREATMENT; NONSURGICAL TREATMENT; PLATING TECHNIQUES; INTERNAL-FIXATION; SUBCONDYLAR FRACTURES; RIGID FIXATION; CLINICAL-EVALUATION; RESORBABLE PLATES; NECK FRACTURES; FOLLOW-UP;
D O I
10.1097/SCS.0000000000002754
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: The aim of this in vivo study is to compare the single-titanium, double-titanium mini plate, and single resorbable plate systems used in internal rigid fixation of the unilateral mandibular condylar fractures on new design biomechanical model. Methods: Thirty synthetic polyurethane models were used for biomechanical testing. Fracture lines were created for each model. Fragments were fixed with single-titanium plates in Group A (n = 10), double-titanium plates in Group B (n = 10), and single biodegradable plate (PPLA) in Group C (n = 10). Masticatory forces were applied to the models and the biomechanical properties of the titanium plate and screws, resorbable plate, and screws were evaluated. Results: The average failure force for Group A, Group B, and Group C is 199, 324, 177N and the average bone displacement for Group A, Group B, Group C is 1.9, 0.3, 2.1 mm, respectively. Discussion: Double titanium plates showed the most acceptable results in the fixation of unilateral subcondylar fractures where the single titanium and biodegradable plate systems failed to provide enough stability in unilateral subcondylar fracture fixation. Biodegradable plate systems are still not an alternative in fixation of unilateral condylar fractures.
引用
收藏
页码:1277 / 1281
页数:5
相关论文
共 50 条
  • [31] Fixation techniques for transverse acetabular fractures: Comparison of different biomechanical loading patterns
    Veeresh, Vivek
    Bansal, Hemant
    Mittal, Samarth
    Trikha, Vivek
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (06): : 2385 - 2385
  • [32] Effect of different orientations of screw fixation for radial head fractures: a biomechanical comparison
    Xuchao Shi
    Tianlong Pan
    Dengying Wu
    Ningyu Cai
    Rong Chen
    Bin Li
    Rui Zhang
    Chengwei Zhou
    Jun Pan
    Journal of Orthopaedic Surgery and Research, 12
  • [33] Biomechanical comparison of locking compression plate fixation and a novel pedicle screw external fixation to repair equine mandibular fractures
    Monck, Samantha L.
    McGilvray, Kirk C.
    Easley, Jeremiah T.
    VETERINARY SURGERY, 2020, 49 (05) : 997 - 1006
  • [34] The role of open reduction and internal fixation in unilateral fractures of the mandibular condyle: a prospective study
    Hyde, N
    Manisali, M
    Aghabeigi, B
    Sneddon, K
    Newman, L
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2002, 40 (01): : 19 - 22
  • [35] Biomechanical Loading Comparison between Titanium and Bioactive Resorbable Screw Systems for Fixation of Intracapsular Condylar Head Fractures
    Sukegawa, Shintaro
    Yamamoto, Norio
    Nakano, Keisuke
    Takabatake, Kiyofumi
    Kawai, Hotaka
    Kanno, Takahiro
    Nagatsuka, Hitoshi
    Furuki, Yoshihiko
    MATERIALS, 2020, 13 (14)
  • [36] Comparison of the Stability of Mandibular Sagittal Osteotomy Fixation between Two Types of Titanium Miniplates: A Biomechanical Study in Sheep Mandibles
    Trento, Guilherme dos Santos
    Pires, Felipe Andrade
    dos Santos, Fabio Andre
    da Costa, Delson Joao
    Barbosa Rebellato, Nelson Luis
    Kluppel, Leandro Eduardo
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2018, 11 (02) : 114 - 117
  • [37] Biomechanical comparison of fixation methods in transverse olecranon fractures: A cadaveric study
    Prayson, MJ
    Williams, JL
    Marshall, MP
    Scilaris, TA
    Lingenfelter, EJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) : 565 - 572
  • [38] Biomechanical Comparison of Superior Versus Anterior Plate Position for Fixation of Distal Clavicular Fractures: A New Model
    Wilkerson, James
    Paryavi, Ebrahim
    Kim, Hyunchul
    Murthi, Anand
    Pensy, Raymond A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (01) : E13 - E17
  • [39] Biomechanical evaluation of various rigid internal fixation modalities for condylar-base-associated multiple mandibular fractures: A finite element analysis
    Li, Jie
    Xu, Chong-tao
    Li, Ying
    Liang, Yuan
    Wu, Wei
    Li, Chang-yi
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (09) : 2787 - 2803
  • [40] ANALYSIS OF THE EFFECT OF INTERNAL TITANIUM PLATE FIXATION IN TREATING DIFFERENT TYPES OF MANDIBULAR CONDYLE FRACTURES
    Wang, J.
    Wang, G. L.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 119 : 17 - 17