Stereotactic target localization accuracy in interventional magnetic resonance imaging

被引:3
|
作者
Samset, E [1 ]
Hirschberg, H
机构
[1] Univ Oslo, Rikshosp, Intervent Ctr, Natl Hosp Norway, NO-0027 Oslo, Norway
[2] Univ Oslo, Natl Hosp Norway, Dept Neurosurg, NO-0027 Oslo, Norway
关键词
functional stereotactic surgery; accuracy; magnetic resonance imaging; target determination;
D O I
10.1159/000070832
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: To compare stereotactic target determination, based on images obtained from interventional MRI (iMRI), conventional closed MR and CT. Methods: Stereotactic coordinates for 55 targets in an artificial scull were derived from iMRI scans and compared using CT as the standard. Stereotactic coordinates were also derived from iMRI scans in a series of patients and compared using iMRI fused with CT as the standard. Results: The mean difference between targets in the skull phantom determined from iMRI and CT images was 0.90 +/- 0.28 mm, with a maximum difference of 1.57 mm. The mean difference between targets in the patients derived from iMRI alone and interventional MR fused with CT was 1.39 +/- 0.54 mm, with a maximum difference of 2.47 mm. Discussion: The results indicate that iMRI can be used for stereotactic target localization. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [41] Functional magnetic resonance imaging for stereotactic radiosurgery
    Schulder, M
    Liu, WC
    Jacobs, A
    Cathcart, CS
    Carmel, PW
    RADIOSURGERY 1999, 2000, 3 : 124 - 134
  • [42] Functional magnetic resonance imaging in a stereotactic setup
    Debus, J
    Essig, M
    Schad, LR
    Wenz, F
    Baudendistel, K
    Knopp, MV
    Engenhart, R
    Lorenz, WJ
    MAGNETIC RESONANCE IMAGING, 1996, 14 (09) : 1007 - 1012
  • [43] Increased Frameless Stereotactic Accuracy With High-Field Intraoperative Magnetic Resonance Imaging COMMENTS
    Starreveld, Yves
    Dammers, Ruben
    Bakay, Roy A. E.
    Vannemreddy, Prasad
    Dorward, Ian G.
    NEUROSURGERY, 2012, 71 : 327 - 328
  • [45] Image-Guided Analysis of Target Localization Accuracy in Stereotactic Radiosurgery
    Calvo Ortega, J.
    Casals, J.
    San Jose, S.
    Moragues, S.
    Pozo, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S786 - S786
  • [46] Magnetic resonance imaging as a localization tool
    Hoffman, Kristen A.
    VETERINARY TECHNICIAN, 2006, 27 (12): : 744 - +
  • [47] Interventional breast MR imaging: Clinical use of a stereotactic localization and biopsy device
    Kuhl, CK
    Elevelt, A
    Leutner, CC
    Gieseke, J
    Pakos, E
    Schild, HH
    RADIOLOGY, 1997, 204 (03) : 667 - 675
  • [48] Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery
    Tronnier, VM
    Wirtz, CR
    Knauth, M
    Lenz, G
    Pastyr, O
    Bonsanto, MM
    Albert, FK
    Kuth, R
    Staubert, A
    Schlegel, W
    Sartor, K
    Kunze, S
    NEUROSURGERY, 1997, 40 (05) : 891 - 900
  • [49] Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery
    Bernays, RL
    Laws, ER
    NEUROSURGERY, 1997, 41 (04) : 999 - 999
  • [50] New therapies for interventional cardiovascular magnetic resonance imaging
    Saborowski, Olaf
    Bremerich, Jens
    Bongartz, Georg
    Saeed, Maythem
    HERZ, 2008, 33 (05) : 323 - 333