Investigation on the thermal performance of a composite Trombe wall under steady state condition

被引:54
|
作者
Zhou, Liqun [1 ]
Huo, Junpeng [2 ]
Zhou, Tong [3 ]
Jin, Shufeng [1 ]
机构
[1] Lanzhou Univ Technol, Coll Petrochem Technol, Lanzhou 730050, Peoples R China
[2] Univ Alberta, Dept Mech Engn, Edmonton, AB T6R 1Y2, Canada
[3] Gansu Urban & Rural Planning Design Inst Co Ltd, Lanzhou 730030, Peoples R China
关键词
Trombe wall; Water wall; Low-temperature water; Energy analysis; Exergy analysis; Heat loss; WATER WALL; SIMULATION; GLASS; COLLECTOR; EXERGY;
D O I
10.1016/j.enbuild.2020.109815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A composite Trombe wall is proposed which combines the water wall with the traditional Trombe wall. Computational fluid dynamics models for different types of Trombe walls were developed to investigate the flow and thermal performance. A good agreement was achieved between simulation results and relevant literature's data. The result shows that the Water Trombe wall could achieve best thermal performance. It can improve the operating efficiency during daytime. The thermal efficiency of the Water Trombe wall is 3.3% higher than the traditional Trombe wall at certain conditions. At nighttime, this structure has the advantage to directly utilize low-temperature water for decreasing building's heat loss. Under low irradiation conditions, the efficiency is 7.2% higher than the traditional Trombe wall. In simulated conditions, the results indicate that the Water Trombe wall can reduce heat loss by 31% compared with the traditional Trombe wall at night. The influence of temperature and velocity of low-temperature water was studied. The mass flow rate of water has minor effect on thermal performance of the Water Trombe wall. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Numerical investigation of the heating performance of normal and new designed Trombe wall
    Rabani, Mehran
    Kalantar, Vali
    HEAT AND MASS TRANSFER, 2016, 52 (06) : 1139 - 1151
  • [22] A numerical study on the effect of vent/wall area ratio on Trombe wall thermal performance
    Kaya, Ercan Serif
    Aksel, Murat
    Yigit, Sadik
    Acikara, Turgut
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2021, 174 (05) : 224 - 234
  • [23] Numerical investigation of the heating performance of normal and new designed Trombe wall
    Mehran Rabani
    Vali Kalantar
    Heat and Mass Transfer, 2016, 52 : 1139 - 1151
  • [24] EXPERIMENTAL STUDY OF THERMAL PERFORMANCE OF NEW DYNAMIC THERMAL INSULATED PCM TROMBE WALL
    Zhou S.
    Ghani R.A.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (02): : 10 - 15
  • [25] On the thermal inertia of the wall of a drum dryer under a cyclic steady state operation
    Kostoglou, M
    Karapantsos, TD
    JOURNAL OF FOOD ENGINEERING, 2003, 60 (04) : 453 - 462
  • [26] Theoretical study on thermal performance of Trombe wall combined with solar air collector
    Bie, Yu
    Zhou, Fang
    Hu, Ming Fu
    Peng, Qian
    Mao, Wen Yuan
    Chang, Jing Hua
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 208 - +
  • [27] Transient Simulation of the Thermal Performance of a Novel Phase Change Material Trombe Wall
    Zhang, Tianhu
    Wang, Hai
    Ding, Jieran
    Tang, Shoufeng
    Yuan, Deling
    Rao, Yandi
    COATINGS, 2025, 15 (03):
  • [28] Thermal stresses in a thermoplastic composite disc under a steady state temperature distribution
    Sayman, Onur
    Arman, Yusuf
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2006, 25 (16) : 1709 - 1722
  • [29] Steady State Creep of Isotropic Rotating Composite Disc Under Thermal Gradation
    Bose, Tania
    Rattan, Minto
    Chamoli, Neeraj
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2017, 9 (06)
  • [30] Thermal Energy Storage Possibilities in the Composite Trombe Wall Modified with a Phase Change Material
    Krason, Joanna
    Miasik, Przemyslaw
    Starakiewicz, Aleksander
    Licholai, Lech
    ENERGIES, 2025, 18 (06)