GEANT4 characterization of the neutronic behavior of the active zone of the MEGAPIE spallation target

被引:5
|
作者
Lamrabet, Abdesslam [1 ]
Maghnouj, Abdelmajid [1 ]
Tajmouati, Jaouad [1 ]
Bencheikh, Mohamed [2 ]
机构
[1] Univ Sidi Mohamed Ben Abdellah, Fac Sci Dhar El Mahraz, Dept Phys, Fes 30000, Morocco
[2] Hassan II Univ Casablanca, Fac Sci & Technol Mohammedia, Dept Phys, Mohammadia, Morocco
关键词
Neutron flux; Micro-detectors; MEGAPIE target; GEANT4; Simulation; SIMULATIONS; DEPOSITION; SCATTERING; EMISSION; PHYSICS; YIELDS; EVENT; MODEL; GATE;
D O I
10.1016/j.net.2021.05.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The increasing interest that GEANT4 is gaining nowadays, because of its special capabilities, prompted us to address its reliability in neutronic calculation for the realistic and complex spallation target MEGAPIE of the Paul Scherrer Institute of Switzerland. In this paper we have specifically addressed the neutronic characterization of the active zone of this target. Three physical quantities are evaluated: neutron flux spectra and total neutron fluxes on target's z-axis, and the neutron yield as a function of the target's altitude and radius. Comparison of the obtained results with those of the MCNPX reference code and some experimental measurements have confirmed the impact of the geometrical and proton beam models on the neutron fluxes. It has also allowed to reveal the intrinsic influence of the code type. The resulting differences reach a factor of similar to 2 for the beam model and 4-18% for the other parameters cumulated. The analysis of the neutron yield has led us to conclude that: 1) Increasing the productivity of the MEGAPIE target cannot be achieved simply by increasing the thickness of the target, if the irradiation parameters are not modified. 2) The size of the spallation area needs to be redefined more precisely. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:3164 / 3170
页数:7
相关论文
共 50 条
  • [21] Application of automated weight windows to spallation neutron source shielding calculations using Geant4
    Stenander, John
    DiJulio, Douglas D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 798 : 167 - 171
  • [22] Validation of Geant4 Hadronic Generators versus Thin Target Data
    Banerjee, S.
    Folger, G.
    Ivanchenko, A.
    Ivanchenko, V. N.
    Kossov, M.
    Quesada, J. M.
    Schaelicke, A.
    Uzhinsky, V.
    Wenzel, H.
    Wright, D. H.
    Yarba, J.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2010): EVENT PROCESSING, 2011, 331
  • [23] Development and validation of analysis code for spallation products behavior in LBE coolant system of ADS comparing with the distribution data in MEGAPIE spallation target
    Miyahara, Shinya
    Arita, Yuji
    Nakano, Keita
    Maekawa, Fujio
    Sasa, Toshinobu
    Obayashi, Hironari
    Takei, Hayanori
    NUCLEAR ENGINEERING AND DESIGN, 2023, 403
  • [24] Modeling of a Cyclotron Target for the Production of C-11 with Geant4
    Chiappiniello, Andrea
    Zagni, Federico
    Infantino, Angelo
    Vichi, Sara
    Cicoria, Gianfranco
    Morigi, Maria Pia
    Marengo, Mario
    CURRENT RADIOPHARMACEUTICALS, 2018, 11 (02) : 92 - 99
  • [25] A Geant4 physics list for spallation and related nuclear physics applications based on INCL and ABLA models
    Heikkinen, A.
    Boudard, A.
    Kaitaniemi, P.
    Folger, G.
    17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [26] Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations
    Szentmiklosi, Laszlo
    Belgya, Tamas
    Maroti, Boglarka
    Kis, Zoltan
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 553 - 558
  • [27] Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations
    László Szentmiklósi
    Tamás Belgya
    Boglárka Maróti
    Zoltán Kis
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 553 - 558
  • [28] Characterization of optical transport effects on EPID dosimetry using Geant4
    Blake, Samuel J.
    Vial, Philip
    Holloway, Lois
    Greer, Peter B.
    McNamara, Aimee L.
    Kuncic, Zdenka
    MEDICAL PHYSICS, 2013, 40 (04)
  • [29] GEANT4 STUDIES OF AN ACTIVE SCANNING SYSTEM FOR HADRONTHERAPY TREATMENT OF UVEAL MELANOMAS
    Rimoldi, A.
    Fontana, A.
    Riccardi, C.
    Pirola, M.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S1 - S1
  • [30] Energy distributions of proton interactions in MCNPX and GEANT4 codes using a slab target
    Wang, B
    Xu, XG
    Jiang, H
    Paganetti, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2029 - 2029