Application of a novel immunomagnetic separation-bacteriophage assay for the detection of Salmonella enteritidis and Escherichia coli O157:H7 in food

被引:57
|
作者
Favrin, SJ
Jassim, SA
Griffiths, MW [1 ]
机构
[1] Univ Guelph, Dept Food Sci, Guelph, ON N1G 2W1, Canada
[2] Univ Guelph, Canadian Res Inst Food Safety, Guelph, ON N1G 2W1, Canada
关键词
Salmonella enteritidis; detection; immunomagnetic separation; bacteriophage; Escherichia coli O157 : H7;
D O I
10.1016/S0168-1605(02)00483-X
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Salmonella infection is the second most prevalent cause of foodborne illness in most developing countries. Meat, poultry, and dairy products are frequently implicated in outbreaks. The objective of this study was to apply a novel immunomagnetic separation (IMS)-bacteriophage assay to the detection of Salmonella enteritidis in artificially inoculated skimmed milk powder, chicken rinses, and ground beef In all food types tested, the IMS-bacteriophage assay was able to detect an average of 3 CFU of S. enteritidis in 25 g or ml of food sample. Total assay time including pre-enrichment is about 20 h. The results indicate that the IMS-bacteriophage assay is a rapid and sensitive means of detecting S. enteritidis in these foods. The assay was successfully adapted to the detection of Escherichia coli O157:H7 and was able to detect E. coli in ground beef at the lowest inoculation level tested, 2 CFU/g. The assay was also adapted to the simultaneous detection of S. enteritidis and E. coli. The results indicate that the IMS-bacteriophage assay shows promise for the simultaneous detection of these pathogens, but further development work would be necessary to improve sensitivity and produce reliable results at low inoculation levels. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [21] Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7
    Gehring, AG
    Irwin, PL
    Reed, SA
    Tu, SI
    Andreotti, PE
    Akhavan-Tafti, H
    Handley, RS
    JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 293 (1-2) : 97 - 106
  • [22] Effects of thermosonication on the fate of Escherichia coli O157:H7 and Salmonella Enteritidis in mango juice
    Kiang, W. -S.
    Bhat, R.
    Rosma, A.
    Cheng, L. -H.
    LETTERS IN APPLIED MICROBIOLOGY, 2013, 56 (04) : 251 - 257
  • [23] Rapid Quantification of Escherichia coli O157:H7 and Salmonella Typhimurium in Lettuce Using Immunomagnetic Separation and a Microfluidic System
    Tokunaga, Yusuke
    Wakabayashi, Yuki
    Yonogi, Shinya
    Yamaguchi, Nobuyasu
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2024, 47 (11) : 1931 - 1936
  • [24] Quantitative detection of Escherichia coli O157:H7 in ground beef by immunomagnetic separation and polymerase chain reaction
    Guan, J
    Levin, RE
    FOOD BIOTECHNOLOGY, 2002, 16 (02) : 135 - 144
  • [25] Detection of Escherichia coli O157:H7 using immunomagnetic separation and mPCR in Turkish foods of animal origin
    Ertas, N.
    Gonulalan, Z.
    Yildirim, Y.
    Karadal, F.
    Abay, S.
    Al, S.
    LETTERS IN APPLIED MICROBIOLOGY, 2013, 57 (04) : 373 - 379
  • [26] Survival of Salmonella and Escherichia coli O157:H7 in chorizos
    Hew, CM
    Hajmeer, MN
    Farver, TB
    Glover, JM
    Cliver, DO
    JOURNAL OF FOOD PROTECTION, 2005, 68 (10) : 2039 - 2046
  • [27] Aptasensors for rapid detection of Escherichia coli O157:H7 and Salmonella typhimurium
    Wen-he Wu
    Min Li
    Yue Wang
    Hou-xian Ouyang
    Lin Wang
    Ci-xiu Li
    Yu-chen Cao
    Qing-he Meng
    Jian-xin Lu
    Nanoscale Research Letters, 7
  • [28] Immunomagnetic separation of Escherichia coli O157:H7 from environmental and wastewater in South Africa
    Müller, EE
    Grabow, WOK
    Ehlers, MM
    WATER SA, 2003, 29 (04) : 427 - 432
  • [29] Aptasensors for rapid detection of Escherichia coli O157:H7 and Salmonella typhimurium
    Wu, Wen-he
    Li, Min
    Wang, Yue
    Ouyang, Hou-xian
    Wang, Lin
    Li, Ci-xiu
    Cao, Yu-chen
    Meng, Qing-he
    Lu, Jian-xin
    NANOSCALE RESEARCH LETTERS, 2012, 7
  • [30] Establishing of a Method Combined Immunomagnetic Separation with Colloidal Gold Lateral Flow Assay and Its Application in Rapid Detection of Escherichia coli O157:H7
    Cui Xi
    Xiong Qi-Rong
    Xiong Yong-Hua
    Shan Shan
    Lai Wei-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (12) : 1812 - 1816