Total quality management of cobalt-60 sources

被引:1
|
作者
Malkoske, GR [1 ]
机构
[1] MDS Nordion, Qual Regulatory Affairs & Operat Serv, Kanata, ON K2K 1X8, Canada
关键词
cobalt-60; sources; design; manufacture; safety; quality; total quality management;
D O I
10.1016/S0969-806X(98)00276-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Total Quality Management of Cobalt-60 sources by a supplier requires a life cycle approach to source management. This covers various aspects, including design, manufacturing, installation, field inspection, source surveillance and return of cobalt-60 sources at the end of their useful life. The Total Quality Management approach demonstrates a strong industry commitment to the beneficial use of gamma technology for industrial irradiation applications in both developed nations and in those nations who are developing their infrastructure and techniques for the beneficial use of this technology. MDS Nordion continues to demonstrate its support and commitment to the industry by developing and implementing state-of-the-art standards for the safe use of cobalt-60 sources. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:601 / 608
页数:8
相关论文
共 50 条
  • [41] POROUS NICKEL SHEATHING OF COBALT-60
    LOWRY, WS
    BRITISH JOURNAL OF RADIOLOGY, 1959, 32 (380): : 560 - 560
  • [42] AN EVALUATION OF COBALT-60 ROTATIONAL EQUIPMENT
    DEVORE, WD
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 142 - &
  • [43] The accuracy of in vivo dose measurements during Cobalt-60 total body irradiation
    Kosicka, G
    NEOPLASMA, 2003, 50 (01) : 74 - 78
  • [44] COBALT-60 HEAT SOURCE ENCAPSULATION
    ANGERMAN, CL
    FARACI, JP
    KING, FDR
    SYMONDS, AE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 70 - &
  • [45] FILM DOSIMETRY OF COBALT-60 RADIATION
    MAUDERLI, W
    GOULD, DM
    LANE, JW
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1960, 83 (03): : 520 - 524
  • [46] COBALT-60 LEAKS IN TELETHERAPY UNITS
    BRUCER, M
    JOURNAL OF NUCLEAR MEDICINE, 1961, 2 (03) : 244 - 244
  • [47] COBALT-60 BACKSCATTERING BY CONCRETE INTERFACE
    CHILTON, AB
    HENRY, WH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1964, 7 (02): : 363 - &
  • [48] HEAD IRRADIATION OF BURRO WITH COBALT-60
    KUHN, G
    BROWN, DG
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1962, 180 (08): : 670 - &
  • [49] Cobalt-60 container inspection system
    An, Jigang
    Zhou, Liye
    Liu, Yisi
    Wu, Haifeng
    Wu, Zhifang
    Xiang, Xincheng
    Wang, Liqiang
    Zhang, Yanmin
    Liu, Ximing
    Tan, Chunming
    He Jishu/Nuclear Techniques, 2002, 25 (06):
  • [50] DOSIMETRY OF A KILOCURIE COBALT-60 SOURCE
    DAVISON, S
    GOLDBLITH, SA
    PROCTOR, BE
    KAREL, M
    KAN, B
    BATES, CJ
    NUCLEONICS, 1953, 11 (07): : 22 - 26