Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

被引:206
|
作者
Lee, Young Han [1 ,2 ]
Park, Kwan Kyu [3 ]
Song, Ho-Taek [1 ,2 ]
Kim, Sungjun [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol, Res Inst Radiol Sci, Med Convergence Res Inst,Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Severance Biomed Sci Inst, Coll Med, Seoul 120752, South Korea
[3] Yonsei Univ, Dept Orthopaed Surg, Coll Med, Seoul 120752, South Korea
关键词
Dual-energy CT; Computed tomography; Metallic artefacts; REFORMATTED PROJECTIONS; COMPUTED-TOMOGRAPHY; HIP; REPLACEMENT; HARDWARE; IMPLANTS;
D O I
10.1007/s00330-011-2370-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). Methods The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. Results The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Conclusion Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. Key Points Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. However image quality is influenced by the prosthesis composition and other parameters. We should be aware about potential overcorrection when using GSI-MARs.
引用
收藏
页码:1331 / 1340
页数:10
相关论文
共 50 条
  • [21] Deep learning-based metal artefact reduction in PET/CT imaging
    Arabi, Hossein
    Zaidi, Habib
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 6384 - 6396
  • [22] Metal artefact reduction of different alloys with dual energy computed tomography (DECT)
    Anand John Vellarackal
    Achim Hermann Kaim
    Scientific Reports, 11
  • [23] Metal artefact reduction of different alloys with dual energy computed tomography (DECT)
    Vellarackal, Anand John
    Kaim, Achim Hermann
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software
    Yue, Dong
    Rong, Cheng Fan
    Ning, Cai
    Liang, Hu
    Lian, Liu Ai
    Xin, Wang Ru
    Hong, Luo Ya
    ACTA RADIOLOGICA, 2018, 59 (07) : 853 - 860
  • [25] Dental CT metal artefact reduction based on sequential substitution
    Tohnak, S.
    Mehnert, A. J. H.
    Mahoney, M.
    Crozier, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (03) : 184 - 190
  • [26] Metal artefact reduction with cone beam CT: an in vitro study
    Bechara, B. B.
    Moore, W. S.
    McMahan, C. A.
    Noujeim, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) : 248 - 253
  • [27] Metal artefact reduction in low-dose computed tomography: Benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging
    Huflage, H.
    Grunz, J-P
    Hackenbroch, C.
    Halt, D.
    Luetkens, K. S.
    Schmidt, A. M. Alfred
    Patzer, T. S.
    Ergun, S.
    Bley, T. A.
    Kunz, A. S.
    RADIOGRAPHY, 2022, 28 (03) : 690 - 696
  • [28] CT metal artefact reduction for internal fixation of the proximal humerus: Value of mono-energetic extrapolation from dual-energy and iterative reconstructions
    Winklhofer, S.
    Benninger, E.
    Spross, C.
    Morsbach, F.
    Rahm, S.
    Ross, S.
    Jost, B.
    Thali, M. J.
    Stolzmann, P.
    Alkadhi, H.
    Guggenberger, R.
    CLINICAL RADIOLOGY, 2014, 69 (05) : E199 - E206
  • [29] Reduction of metallic coil artifacts in CT angiography with metal artefact reduction (MAR) algorithm
    David, A.
    Ray, A.
    Hermet, P. L.
    Quieffin, F.
    D'Assignies, G.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (06) : 381 - 382
  • [30] Orthopaedic and non-orthopaedic applications of a single-energy iterative metal artefact reduction technique and other metal artefact reduction techniques explained
    Khor, Robert
    Buchan, Kevin
    Kuganesan, Ahilan
    Ardley, Nicholas
    Lau, Kenneth K.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):