Effect of X-ray exposure on the pharmaceutical quality of drug tablets using X-ray inspection equipment

被引:8
|
作者
Uehara, Kazuaki [1 ]
Tagami, Tatsuaki [1 ]
Miyazaki, Itaru [2 ]
Murata, Norikazu [2 ]
Takahashi, Yoshifumi [2 ]
Ohkubo, Hiroshi [2 ]
Ozeki, Tetsuya [1 ]
机构
[1] Nagoya City Univ, Grad Sch Pharmaceut Sci, Drug Delivery & Nano Pharmaceut, Mizuho Ku, Nagoya, Aichi 4678603, Japan
[2] Anritsu Ind Solut Co Ltd, Atsugi, Kanagawa, Japan
关键词
Aluminum foil press-through packaging; drug quality; drug stability; formulation test; X-ray inspection equipment; STABILITY; TEMPERATURE; DISSOLUTION; STORAGE;
D O I
10.3109/03639045.2014.917093
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Context: X-ray inspection equipment is widely used to detect missing materials and defective goods in opaque containers. Its application has been expanded to the pharmaceutical industry to detect the presence of drug tablets in aluminum foil press-through packaging. However, the effect of X-rays on the pharmaceutical quality of drug tablets is not well known. Objective: In this study, the effect of X-rays on the pharmaceutical quality of drug tablets was investigated. Methods: Exposure of acetaminophen, loxoprofen and mefenamic acid tablets to X-ray doses of 0.34 mGy (thrice the dose by X-ray scanning) to 300 Gy (maximum dose from our X-ray equipment) was demonstrated, and the samples were evaluated by formulation tests. Results: Exposure to X-rays did not affect the pharmaceutical quality of the drug content. The samples exposed to X-rays exhibited almost the same profile in formulation tests (dissolution test, disintegrating test and hardness test) as control samples (0 Gy). The combination of X-ray exposure with accelerated temperature and humidity tests (six months) also did not affect the pharmaceutical quality. The color change of light-sensitive drugs (nifedipine and furosemide tablets) after X-ray exposure was negligible (< 1.0). In contrast, tablet color was remarkably changed by light from a D65 lamp. Conclusion: The X-ray scanning and X-ray exposure under our experimental conditions did not affect the pharmaceutical quality of drug tablets.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 50 条
  • [21] Automated Inspection using X-ray Imaging
    Chen, Wenfei
    Miao, Zuohua
    Ming, Delie
    TRUSTCOM 2011: 2011 INTERNATIONAL JOINT CONFERENCE OF IEEE TRUSTCOM-11/IEEE ICESS-11/FCST-11, 2011, : 1769 - 1772
  • [22] X-RAY SPECTROMETRY EQUIPMENT
    BROEKAERT, JAC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (02) : 208 - 210
  • [23] X-RAY EQUIPMENT FOR CRYSTALLOGRAPHY
    HAPPEY, F
    NATURE, 1945, 155 (3930) : 244 - 245
  • [24] PANORAMIC X-RAY EQUIPMENT
    VANAKEN, J
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1973, 86 (05): : 1050 - 1059
  • [25] X-RAY PHYSICS AND EQUIPMENT
    不详
    LANCET, 1966, 1 (7436): : 527 - &
  • [26] Implementation of an X-ray radiation protective equipment inspection program
    Michel, R
    Zorn, MJ
    HEALTH PHYSICS, 2002, 82 (02): : S51 - S53
  • [27] X-ray diffraction III: Pharmaceutical applications of x-ray powder diffraction
    Brittain, HG
    SPECTROSCOPY, 2001, 16 (07) : 14 - +
  • [28] X-ray Diffraction III Pharmaceutical Applications of X-ray Powder Diffraction
    Brittain, Harry G.
    1600, Advanstar Communications (25):
  • [29] X-RAY quality
    McCurdy, Ryan
    Slayton, Andrew
    Stirm, Chuck
    Berry, Philip C.
    MATERIALS EVALUATION, 2012, 70 (09) : 1039 - 1043
  • [30] Effect of X-ray beam quality on determination of exposure index
    Yasumatsu S.
    Tanaka N.
    Iwase K.
    Shimizu Y.
    Morishita J.
    Radiological Physics and Technology, 2016, 9 (1) : 109 - 115