A preliminary study for portable walking distance measurement system using ultrasonic sensors

被引:11
|
作者
Jang, Yongwon [1 ]
Shin, Seungchul [1 ]
Lee, Jeong Won [1 ]
Kim, Seunghwan [1 ]
机构
[1] Elect & Telecommun Res Inst, Taejon 305606, South Korea
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4353535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Efforts have been made to measure the distance traveled by humans in motion, in ways that are compact and accurate, for a long time. There are several ways to measure the distance moved by walking or running in daily fife, some of which already use commercial products, but those methods are inaccurate. In this study, a new method is provided using ultrasonic sensors, and this is the fundamental study. The newly devised 'Portable Walking Distance Measurement System' was developed using ultrasonic wave characteristics and has approximately 90% accuracy. This result provides an opportunity to estimate human activities and the developed system would provide more comfort and an exact way to measure the walking distance in daffy life and could be applied to exercise.
引用
收藏
页码:5290 / 5293
页数:4
相关论文
共 50 条
  • [31] Ultrasonic Distance Measurement Method by Using the Envelope Model of Received Signal Based on System Dynamic Model of Ultrasonic Transducers
    Choe, Jin-Hee
    Lee, Kook-Sun
    Choy, Ick
    Cho, Whang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (02) : 981 - 988
  • [32] Development of Inter-Vehicle Distance Measurement System using Camera-Equipped Portable Device
    Sasaki, Nobuo
    Tomaru, Syuhei
    Nakamura, Shiori
    2017 17TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2017, : 994 - 997
  • [33] A High-Resolution Ultrasonic Distance Measurement System Using Vernier Caliper Phase Meter
    Lee, Ke-Yu
    Huang, Chih-Feng
    Huang, Sin-San
    Huang, Ke-Nung
    Young, Ming-Shing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (11) : 2924 - 2931
  • [34] A Novel Distance Measurement Approach Using Shape Matching in Narrow-Band Ultrasonic System
    Mirshahi, Shiva
    Mas, Orestes
    IFAC PAPERSONLINE, 2015, 48 (03): : 406 - 411
  • [35] Study of Portable Shaft Power Measurement System
    Chen, Yong
    Yu, Wenming
    MECHANICAL DESIGN AND POWER ENGINEERING, PTS 1 AND 2, 2014, 490-491 : 1522 - 1525
  • [36] Portable On-line Measurement of the Yarn Quality Using CCD Sensors
    Qin Weigang
    Yang Gongyuan
    Huang Qilan
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 861 - 864
  • [37] Odor measurement by using a portable device with semiconductor gas sensors array
    Guz, Lukasz
    Sobczuk, Henryk
    Suchorab, Zbigniew
    PRZEMYSL CHEMICZNY, 2010, 89 (04): : 378 - 381
  • [38] Foot movement tracking system using ultrasonic sensors and inertial sensors
    Boo J.H.
    Park S.K.
    Suh Y.S.
    Journal of Institute of Control, Robotics and Systems, 2010, 16 (11) : 1117 - 1124
  • [39] Ambulatory Measurement of Foot Kinematics Using Wearable Ultrasonic Sensors
    Qi, Yongbin
    Soh, Cheong Boon
    Gunawan, Erry
    Low, Kay-Soon
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6282 - 6285
  • [40] A study on the measurement system using an ultrasonic sensor in electron beam welding
    Hong, Minsung
    Kim, Jongmin
    Kim, Nohyu
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1715 - 1718