Effect of Angle of Incidence on Macular Thickness and Volume Measurements Obtained by Spectral-Domain Optical Coherence Tomography

被引:17
|
作者
Hariri, Amirhossein
Lee, Sun Young
Ruiz-Garcia, Humberto
Nittala, Muneeswar Gupta
Heussen, Florian M.
Sadda, Srinivas R. [1 ]
机构
[1] Univ So Calif, Keck Sch Med, Doheny Eye Inst, Los Angeles, CA 90033 USA
关键词
EDEMA;
D O I
10.1167/iovs.12-9767
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Evaluation of the effect of angle of incidence on macular thickness and volume measurements obtained by spectral-domain optical coherence tomography (OCT). METHODS. A total of 30 eyes from 15 healthy young subjects underwent macular cube volume scans (512 x 128 protocol) following dilation using the Cirrus spectral domain OCT. For each eye, scans were obtained by positioning the scanning beam in the center of the dilated pupil, as well as in four eccentric positions (approximately 3 mm from the center), superior, inferior, nasal, and temporal to the pupillary center, to create oblique angles of incidence between the light beam and retina. In all cases, the region scanned by the volume cube was centered on the fovea. Macular thickness and volume measurements were computed for volume scan acquisitions, and differences in values between eccentric scans and the central scan were analyzed. RESULTS. Retinal thickness and volume values were observed to increase significantly in all subfields for all eccentrically-obtained scans compared to scans obtained through the center of the pupil. The mean increase in thickness for the various scan positions and subfields ranged from 3.76 to 11.38. Scans that were displaced temporally consistently showed the greatest increase in thickness and volume, whereas nasally positioned scans showed the least increase. The increase in retinal thickness for all subfields correlated significantly with angle of inclination or tilting of the retina. CONCLUSIONS. Macular thickness and volume measurement results may be affected significantly by positioning of the scanning beam in the pupil and resultant angle of incidence on the retina. These findings suggest that care should be taken to position the scanning beam consistently in the center of the pupil to achieve reliable measurements. (Invest Ophthalmol Vis Sci. 2012;53:5287-5291) DOI:10.1167/iovs.12-9767
引用
收藏
页码:5287 / 5291
页数:5
相关论文
共 50 条
  • [31] Longitudinal Study of Macular Folds by Spectral-Domain Optical Coherence Tomography
    Wong, Roger
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (01) : 88 - 92
  • [32] Spectral-Domain Optical Coherence Tomography Findings of Eyes With Macular Telangiectasia
    Prabakaran, S. L.
    Wafapoor, H.
    Prabakaran, S.
    Eaton, A. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] Spectral-Domain Optical Coherence Tomography Use in Macular Diseases: A Review
    Wolf, Sebastian
    Wolf-Schnurrbusch, Ute
    OPHTHALMOLOGICA, 2010, 224 (06) : 333 - 340
  • [34] Spectral-Domain Optical Coherence Tomography Characteristics of Macular Contusion Trauma
    Yu, Weihong
    Zheng, Lin
    Zhang, Zhiqiao
    Dai, Rongping
    Dong, Fangtian
    OPHTHALMIC RESEARCH, 2012, 47 (04) : 220 - 224
  • [35] Intraoperative Spectral-Domain Optical Coherence Tomography for Macular Pucker Surgery
    Baranano, D. E.
    Fortun, J. A.
    Ray, R.
    Charkoudian, L.
    Bergstrom, C.
    Cribbs, B.
    Schwent, B.
    Hubbard, G., III
    Srivastava, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] Longitudinal Study of Macular Folds by Spectral-domain Optical Coherence Tomography
    dell'Omo, Roberto
    Costagliola, Ciro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (04) : 757 - 758
  • [37] Evaluation of Artifacts Associated with Macular Spectral-Domain Optical Coherence Tomography
    Han, Ian C.
    Jaffe, Glenn J.
    OPHTHALMOLOGY, 2010, 117 (06) : 1177 - U211
  • [38] Artifacts in Spectral-Domain Optical Coherence Tomography Measurements in Glaucoma
    Asrani, Sanjay
    Essaid, Luma
    Alder, Brian D.
    Santiago-Turla, Cecilia
    JAMA OPHTHALMOLOGY, 2014, 132 (04) : 396 - 402
  • [39] Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography
    Balasubramanian, Madhusudhanan
    Bowd, Christopher
    Vizzeri, Gianmarco
    Weinreb, Robert N.
    Zangwill, Linda M.
    OPTICS EXPRESS, 2009, 17 (05): : 4019 - 4036
  • [40] Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
    Hanumunthadu, Daren
    Keane, Pearse A.
    Balaskas, Konstantinos
    Dubis, Adam M.
    Kalitzeos, Angelos
    Michaelides, Michel
    Patel, Praveen J.
    OPHTHALMOLOGY AND THERAPY, 2021, 10 (04) : 913 - 922