Graphene-Derivatized Silica Composite as Solid-Phase Extraction Sorbent Combined with GC-MS/MS for the Determination of Polycyclic Musks in Aqueous Samples

被引:14
|
作者
Li, Cheng [1 ,2 ]
Chen, Jiayi [1 ,2 ]
Chen, Yan [1 ,2 ]
Wang, Jihua [1 ]
Ping, Hua [1 ]
Lu, Anxiang [1 ,2 ]
机构
[1] Beijing Acad Agr & Forestry Sci, Beijing Res Ctr Agr Stand & Testing, Beijing 100097, Peoples R China
[2] Beijing Municipal Key Lab Agr Environm Monitoring, Beijing 100097, Peoples R China
来源
MOLECULES | 2018年 / 23卷 / 02期
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
graphene; solid-phase extraction; polycyclic musks; water; GC-MS/MS; PHTHALATE ACID-ESTERS; WATER SAMPLES; ENVIRONMENTAL WATER; GAS-CHROMATOGRAPHY; MASS-SPECTROMETRY; AROMATIC-HYDROCARBONS; MAGNETIC GRAPHENE; SYNTHETIC MUSKS; RISK-ASSESSMENT; SURFACE WATERS;
D O I
10.3390/molecules23020318
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Polycyclic musks (PCMs) have recently received growing attention as emerging contaminants because of their bioaccumulation and potential ecotoxicological effects. Herein, an effective method for the determination of five PCMs in aqueous samples is presented. Reduced graphene oxide-derivatized silica (rGO@silica) particles were prepared from graphene oxide and aminosilica microparticles and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. PCMs were preconcentrated using rGO@silica as the solid-phase extraction sorbent and quantified by gas chromatography-tandem mass spectrometry. Several experimental parameters, such as eluent, elution volume, sorbent amount, pH, and sample volume were optimized. The correlation coefficient (R) ranged from 0.9958 to 0.9992, while the limits of detection and quantitation for the five PCMs were 0.3-0.8 ng/L and 1.1-2.1 ng/L, respectively. Satisfactory recoveries were obtained for tap water (86.6-105.9%) and river water samples (82.9-107.1%), with relative standard deviations <10% under optimal conditions. The developed method was applied to analyze PCMs in tap and river water samples from Beijing, China. Galaxolide (HHCB) and tonalide (AHTN) were the main PCM components detected in one river water sample at concentrations of 18.7 for HHCB, and 11.7 ng/L for AHTN.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Determination of steroidal oestrogens in tap water samples using solid-phase extraction on a molecularly imprinted polymer sorbent and quantification with gas chromatography-mass spectrometry (GC-MS)
    Zacs, D.
    Perkons, I.
    Bartkevics, V.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2016, 188 (07)
  • [42] 3D graphene–carbon nanotubes-based solid-phase extraction technique combined with GC–MS for the determination of organophosphorus pesticides in water samples
    Peng Sun
    Mengyao Liu
    Xiaolin Zhang
    Rui Yan
    Journal of the Iranian Chemical Society, 2020, 17 : 2275 - 2282
  • [43] Determination of steroidal oestrogens in tap water samples using solid-phase extraction on a molecularly imprinted polymer sorbent and quantification with gas chromatography-mass spectrometry (GC-MS)
    D. Zacs
    I. Perkons
    V. Bartkevics
    Environmental Monitoring and Assessment, 2016, 188
  • [44] Covalent immobilization of covalent organic framework on stainless steel wire for solid-phase microextraction GC-MS/MS determination of sixteen polycyclic aromatic hydrocarbons in grilled meat samples
    Ma, Tian-Tian
    Shen, Xiao-Fang
    Yang, Cheng
    Qian, Hai-Long
    Pang, Yue-Hong
    Yan, Xiu-Ping
    TALANTA, 2019, 201 : 413 - 418
  • [45] Selective and sensitive GC-MS analysis of carcinogenic N-nitrosodimethylamine in pharmaceuticals using a magnetic coconut carbon composite as a solid-phase extraction sorbent
    Ali, Hazim M.
    Alsohaimi, Ibrahim Hotan
    Rizwan Khan, Mohammad
    Naguib, Ibrahim A.
    Busquets, Rosa
    Alam, Pravej
    Ainousah, Bayan E.
    Gamal, Mohammed
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2023, 17 (01):
  • [46] DETERMINATION OF METHYL ISOTHIOCYANATE IN WINE BY USING SOLID-PHASE EXTRACTION/HPLC, GC AND GC/MS
    TERADA, H
    NAGAI, Y
    MIYABE, M
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1992, 33 (06): : 586 - 592
  • [47] Determination of acephate and its degradation product methamidophos in soil and water by solid-phase extraction (SPE) and GC-MS
    St-Amand, AD
    Girard, L
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (10) : 739 - 748
  • [48] Solid-phase extraction based in tube filled-magnetic carbon nanotubes coupled with GC-MS for analysis of polycyclic aromatic hydrocarbons in environmental samples
    Zhou, Chanyuan
    Meng, Tiao
    Yang, Chunyan
    Yang, Yike
    Chinese Journal of Analysis Laboratory, 2021, 40 (09) : 1015 - 1020
  • [49] Porcine follicular fluids: Comparison of solid-phase extraction and matrix solid-phase dispersion for the GC-MS determination of hormones during follicular growth
    Bianchi, F.
    Careri, M.
    Mangia, A.
    Musci, M.
    Santini, S. E.
    Basini, G.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 711 - 717
  • [50] GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods
    Temerdashev, Azamat
    Nesterenko, Pavel
    Dmitrieva, Ekaterina
    Zhurkina, Kseniya
    Feng, Yu-Qi
    MOLECULES, 2022, 27 (18):