Radiation dose to patients and personnel during intraoperative digital subtraction angiography

被引:0
|
作者
Derdeyn, CP [1 ]
Moran, CJ [1 ]
Eichling, JO [1 ]
Cross, DT [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, Neuroradiol Sect, St Louis, MO 63110 USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The use of intraoperative angiography to assess the results of neurovascular surgery is increasing, The purpose of this study was to measure the radiation dose to patients and personnel during intraoperative angiography and to determine the effect of experience. METHODS: Fifty consecutive intraoperative angiographic studies were performed during aneurysmal clipping or arteriovenous malformation resection from June 1993 to December 1993 and another 50 from December 1994 to June 1995, Data collected prospectively included fluoroscopy time, digital angiography time, number of views, and amount of time the radiologist spent in the room. Student's t-test was used to assess statistical significance. Effective doses were calculated from radiation exposure measurements using adult thoracic and head phantoms, RESULTS: The overall median examination required 5.2 minutes of fluoroscopy, 55 minutes of operating room use, 40 seconds of digital angiographic series time, and four views and runs. The mean room time and the number of views and runs increased in the second group of patients. A trend toward reduced fluoroscopy time was noted. Calculated effective doses for median values were as follows: patient, 76.7 millirems (mrems); radiologist, 0.028 mrems; radiology technologist, 0.044 mrems; and anesthesiologist, 0.016 mrems. CONCLUSION: Intraoperative angiography is performed with a reasonable radiation dose to the patient and personnel, The number of angiographic views and the radiologist's time in the room increase with experience.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [11] Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain
    Netwong, Y.
    Krisanachinda, A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [12] 3D cerebral angiography: Radiation dose comparison with digital subtraction angiography
    Schueler, BA
    Kallmes, DF
    Cloft, HJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (08) : 1898 - 1901
  • [13] Radiation Dose during Digital Subtraction Angiography of the Brain-The Influence of Examination Parameters and Patient Factors on the Dose
    Modlinska, Sandra
    Kufel, Jakub
    Janik, Michal
    Czogalik, Lukasz
    Dudek, Piotr
    Rojek, Marcin
    Zbroszczyk, Milosz
    BRAIN SCIENCES, 2024, 14 (08)
  • [14] THE RADIATION-DOSE TO SURGICAL PERSONNEL DURING INTRAOPERATIVE RADIOIMMUNOSCINTIMETRY
    BARES, R
    MULLER, B
    FASS, J
    BUELL, U
    SCHUMPELICK, V
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (02): : 110 - 112
  • [15] Intraoperative digital subtraction angiography. Procedure and significance
    Tenjin, H
    Maekawa, M
    Masaki, H
    Matsumoto, K
    Ueda, S
    11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 907 - 910
  • [16] Estimation of High Framerate Digital Subtraction Angiography Sequences at Low Radiation Dose
    Haouchine, Nazim
    Juvekar, Parikshit
    Xiong, Xin
    Luo, Jie
    Kapur, Tina
    Du, Rose
    Golby, Alexandra
    Frisken, Sarah
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VI, 2021, 12906 : 171 - 180
  • [17] Quantitative Digital Subtraction Angiography Measurement of Arterial Velocity at Low Radiation Dose Rates
    Whitehead, Joseph F.
    Hoffman, Carson A.
    Wagner, Martin G.
    Periyasamy, Sarvesh
    Meram, Ece
    Keller, Marlin E.
    Speidel, Michael A.
    Laeseke, Paul F.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 47 (08) : 1119 - 1126
  • [18] Intraoperative spinal digital subtraction angiography: Technique and results - Comments
    Ogilvy, CS
    Barrow, DL
    Batjer, HH
    NEUROSURGERY, 2003, 52 (03) : 608 - 609
  • [19] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY AFTER THROMBOEMBOLECTOMY - PRELIMINARY EXPERIENCE
    CROLLA, RMPH
    VANDEPAVOORDT, EDWM
    MOLL, FL
    JOURNAL OF ENDOVASCULAR SURGERY, 1995, 2 (02): : 168 - 171
  • [20] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY - A REVIEW OF 112 CONSECUTIVE EXAMINATIONS
    DERDEYN, CP
    MORAN, CJ
    CROSS, DT
    GRUBB, RL
    DACEY, RG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (02) : 307 - 318