Radiation dose to patients and personnel during intraoperative digital subtraction angiography

被引:0
|
作者
Derdeyn, CP [1 ]
Moran, CJ [1 ]
Eichling, JO [1 ]
Cross, DT [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, Neuroradiol Sect, St Louis, MO 63110 USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The use of intraoperative angiography to assess the results of neurovascular surgery is increasing, The purpose of this study was to measure the radiation dose to patients and personnel during intraoperative angiography and to determine the effect of experience. METHODS: Fifty consecutive intraoperative angiographic studies were performed during aneurysmal clipping or arteriovenous malformation resection from June 1993 to December 1993 and another 50 from December 1994 to June 1995, Data collected prospectively included fluoroscopy time, digital angiography time, number of views, and amount of time the radiologist spent in the room. Student's t-test was used to assess statistical significance. Effective doses were calculated from radiation exposure measurements using adult thoracic and head phantoms, RESULTS: The overall median examination required 5.2 minutes of fluoroscopy, 55 minutes of operating room use, 40 seconds of digital angiographic series time, and four views and runs. The mean room time and the number of views and runs increased in the second group of patients. A trend toward reduced fluoroscopy time was noted. Calculated effective doses for median values were as follows: patient, 76.7 millirems (mrems); radiologist, 0.028 mrems; radiology technologist, 0.044 mrems; and anesthesiologist, 0.016 mrems. CONCLUSION: Intraoperative angiography is performed with a reasonable radiation dose to the patient and personnel, The number of angiographic views and the radiologist's time in the room increase with experience.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [1] RADIATION EXPOSURE OF PERSONNEL DURING DIGITAL SUBTRACTION ANGIOGRAPHY
    BRITTON, CA
    WHOLEY, MH
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) : 108 - 110
  • [2] EXPOSURE OF PERSONNEL TO RADIATION DURING DIGITAL SUBTRACTION ANGIOGRAPHY
    BRITTON, CA
    WHOLEY, MH
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S42 - S42
  • [3] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY
    BROWN, MW
    CATHEY, SL
    BOOP, WC
    NEUROSURGERY, 1985, 16 (05) : 727 - 727
  • [4] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY
    MARTIN, N
    BENTSON, J
    VINUELA, F
    CAHAN, L
    FRAZEE, J
    GADE, G
    RAND, R
    REICHER, M
    HIESHIMA, G
    BECKER, D
    NEUROSURGERY, 1988, 22 (04) : 790 - 790
  • [5] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY
    PARKINSON, D
    NEUROSURGERY, 1985, 17 (05) : 869 - 869
  • [6] INTRAOPERATIVE DIGITAL SUBTRACTION ANGIOGRAPHY FOR NEUROSURGERY
    KIRSCH, WM
    ZHU, YH
    WESTERN JOURNAL OF MEDICINE, 1990, 153 (05): : 547 - 548
  • [7] RADIATION-DOSE TO THE OPERATOR DURING DIGITAL SUBTRACTION ANGIOGRAPHY IN THE CONTINUOUS-MODE
    LANGER, M
    GOLDE, G
    FIEGLER, W
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 141 (05): : 544 - 545
  • [8] Analysis of Radiation Doses and Dose Reduction Strategies During Cerebral Digital Subtraction Angiography
    Yi, Ho Jun
    Sung, Jae Hoon
    Lee, Dong Hoon
    Kim, Sang Wook
    Lee, Sang Won
    WORLD NEUROSURGERY, 2017, 100 : 216 - 223
  • [9] Radiation doses to patients from digital subtraction angiography
    Goni, H
    Tsalafoutas, IA
    Tzortzis, G
    Pappas, P
    Bouzas, N
    Loulakas, J
    Georgiou, A
    Georgiou, E
    Yakoumakis, EN
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 251 - 255
  • [10] RADIATION-DOSE DURING DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF THE KIDNEY AND THE AORTIC-ARCH
    NEUFANG, KFR
    EWEN, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 139 (03): : 300 - 303