Performance of four sources of cholesterol oxidase for serum cholesterol determination by the enzymatic endpoint method

被引:16
|
作者
Lolekha, PH [1 ]
Srisawasdi, P
Jearanaikoon, P
Wetprasit, N
Sriwanthana, B
Kroll, MH
机构
[1] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Pathol,Div Clin Chem, Bangkok 10400, Thailand
[2] Khon Kaen Univ, Fac Associated Med Sci, Dept Clin Chem, Khon Kaen 40002, Thailand
[3] Ramkhamheng Univ, Fac Sci, Dept Biotechnol, Bangkok 10240, Thailand
[4] Natl Inst Hlth, Dept Med Sci, New Delhi 110001, India
[5] Univ Texas, SW Med Ctr, Dallas, TX 75216 USA
[6] Dallas Vet Affairs Med Ctr, Dept Pathol & Lab Med, Dallas, TX 75216 USA
关键词
serum cholesterol; enzymatic endpoint method; Streptomyces; Pseudomonas fluorescens; Cellulomonas; Brevibacterium;
D O I
10.1016/j.cccn.2003.10.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Cholesterol oxidase is used for the determination of serum cholesterol. It can be derived from Streptomyces, Pseudomonas fluorescens, Cellulomonas, and Brevibacterium. This study compared the performance characteristics of four enzymes in the endpoint cholesterol determination. Methods: Using the Mega analyzer, we studied assay optimization, linearity, precision, recovery, interference, stability, and compared 110 patient samples. Results: The linearity for the four enzymes was up to 13.0 mmol/l at the optimal enzyme activity. The average within-run CVs ranged from 1.6% to 1.9% and between-day ranged from 2.8% to 3.0%, within the NCEP analytical criteria. The analytical recoveries obtained from four reagents ( similar to 96.5%) were excellent. The assays using these enzyme sources compared favorably with the commercial method and appeared accurate near the clinical decision cut-points. Hemoglobin concentration at 1.9 g/l interfered with the P. fluorescens cholesterol oxidase. Bilirubin caused a negative interference while lipemia generated a positive interference with all enzyme sources. Reagents were stable up to 6 weeks. Conclusions: Streptomyces, Cellulomonas, and Brevibacterium were essentially analytically equivalent. Streptomyces and Cellulomonas cholesterol oxidase are one-quarter as expensive Brevibacterium. Cellulomonas is a new source of cholesterol oxidase for determining serum cholesterol by the endpoint method. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 145
页数:11
相关论文
共 50 条
  • [31] ENZYMATIC DETERMINATION OF STEROLS IN FATS AND OILS - SPECIFICITY OF CHOLESTEROL OXIDASE
    RIETSCH, J
    ENTRESSANGLES, B
    REVUE FRANCAISE DES CORPS GRAS, 1980, 27 (04): : 185 - 188
  • [32] KINETIC ENZYMATIC METHOD FOR AUTOMATED-DETERMINATION OF SERUM TOTAL CHOLESTEROL (CH)
    DEEG, R
    ZIEGENHORN, J
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1574 - 1574
  • [33] INTERFERENCE BY BILIRUBIN IN ENZYMATIC DETERMINATION OF SERUM-CHOLESTEROL
    WARTY, VS
    VIRJI, MA
    SELTMAN, HJ
    CLINICAL CHEMISTRY, 1985, 31 (06) : 1024 - 1025
  • [34] A METHOD FOR THE DETERMINATION OF CHOLESTEROL IN BLOOD SERUM
    KLUNGSOYR, L
    HAUKENES, E
    CLOSS, K
    CLINICA CHIMICA ACTA, 1958, 3 (06) : 514 - 518
  • [35] A SIMPLE METHOD FOR THE DETERMINATION OF SERUM CHOLESTEROL
    WATSON, D
    CLINICA CHIMICA ACTA, 1960, 5 (05) : 637 - 643
  • [36] IMPROVED REAGENT FOR THE ENZYMATIC DETERMINATION OF SERUM-CHOLESTEROL
    SIEDEL, J
    SCHLUMBERGER, H
    KLOSE, S
    ZIEGENHORN, J
    WAHLEFELD, AW
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 838 - 839
  • [37] CHEMICAL CHARACTERISTICS AND SOURCES OF ERROR OF AN ENZYMATIC CHOLESTEROL METHOD
    COOPER, GR
    ULLMAN, MD
    HAZLEHURST, J
    MILLER, DT
    BAYSE, DD
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1074 - 1074
  • [38] Determination of total cholesterol in serum by cholesterol esterase and cholesterol oxidase immobilized and co-immobilized on to arylamine glass
    Malik, V
    Pundir, CS
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2002, 35 (03) : 191 - 197
  • [39] CONTINUOUS-FLOW AUTOMATION OF CHOLESTEROL OXIDASE-BASED DETERMINATION OF SERUM-CHOLESTEROL
    LIE, RF
    SCHMITZ, J
    PIERRE, K
    GOCHMAN, N
    CLINICAL CHEMISTRY, 1975, 21 (07) : 942 - 942
  • [40] NEW INDICATOR REACTION FOR CHOLESTEROL DETERMINATION WITH CHOLESTEROL OXIDASE
    HARDERS, HD
    HELGER, R
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1977, 15 (03): : 159 - 159