Energy-resolving X-ray fluorescence detection using synthetic multilayers

被引:17
|
作者
Zhang, K [1 ]
Rosenbaum, G
Bunker, G
机构
[1] IIT, Dept Biol Chem & Phys Sci, Chicago, IL 60616 USA
[2] Argonne Natl Lab, Struct Biol Ctr, Argonne, IL 60439 USA
来源
关键词
fluorescence detectors; X-ray absorption spectroscopy; synthetic multilayers;
D O I
10.1107/S0909049597019535
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The potential of synthetic multilayers for energy-resolving the X-ray fluorescence in X-ray absorption fine structure (XAFS) experiments is discussed. Two detection systems, one using curved multilayers and the other using graded multilayers to select X-ray fluorescence photons, have been designed to cover a wide energy range with a usefully large solid angle. Such a detector will be more advantageous than the barrel-like crystal-array detector because of the unique properties of synthetic multilayers, such as larger horizontal acceptance angles and bandwidth. In addition, the detector should be much simpler to construct and readily accommodates energy changes, especially the detector using graded multilayers. Comparison of the multilayer array detector with conventional detectors, such as ionization chambers and conventional 13-element Ge detectors, shows that the proposed system will be superior, particularly with the increased photon fluxes available from insertion devices and with decreased sample concentration, since this detection system eliminates the 'bad' photons before they enter any X-ray detector. Consequently, the X-ray detector proper for this system does not suffer from the incident-count-rate bottleneck common to current X-ray fluorescence detectors with energy resolution by signal processing. Thus, this new fluorescence detection system will provide tremendous opportunities for XAFS measurements on dilute systems, such as biological systems, at third-generation synchrotron sources.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 50 条
  • [1] ENERGY-RESOLVING DIAMOND DETECTORS FOR X-RAY SPECTROSCOPY
    Girolami, M.
    Allegrini, P.
    Fabbri, A.
    Salvatori, S.
    Conte, G.
    PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS, 2009, : 307 - 312
  • [2] Subpixel x-ray imaging with an energy-resolving detector
    Persson, Mats
    Holmin, Staffan
    Karlsson, Staffan
    Bornefalk, Hans
    Danielsson, Mats
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [3] Resolution improvement in x-ray imaging with an energy-resolving detector
    Persson, Mats
    Danielsson, Mats
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [4] Spectral Signatures of X-ray Scatter Using Energy-Resolving Photon-Counting Detectors
    Lewis, Cale E.
    Das, Mini
    SENSORS, 2019, 19 (22)
  • [5] The role of x-ray Swank factor in energy-resolving photon-counting imaging
    Tanguay, Jesse
    Kim, Ho Kyung
    Cunningham, Ian A.
    MEDICAL PHYSICS, 2010, 37 (12) : 6205 - 6211
  • [6] A tabletop clinical x-ray CT scanner with energy-resolving photon counting detectors
    Cammin, J.
    Srivastava, S.
    Barber, W. C.
    Iwanczyk, J. S.
    Hartsough, N. E.
    Nygard, E.
    Wessel, J. C.
    Malakhov, N.
    Taguchi, K.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [7] Novel Photon-Counting Energy-Resolving Ultra-Fast X-Ray Detector
    Ertosun, M. Guenhan
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Optimization of energy windows to calculate quantitative X-ray images using an energy-resolving photon-counting detector: A simulation study
    Nishigami, Rina
    Kobayashi, Daiki
    Kimoto, Natsumi
    Asahara, Takashi
    Maeda, Tatsuya
    Haba, Tomonobu
    Kanazawa, Yuki
    Yamamoto, Shuichiro
    Hayashi, Hiroaki
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [9] Improved analyzer multilayers for aluminium and boron detection with x-ray fluorescence
    Ricardo, Paulo
    Wiesmann, Jörg
    Nowak, Claudia
    Michaelsen, Carsten
    Bormann, Rüdiger
    Applied Optics, 2001, 40 (16): : 2747 - 2754
  • [10] Improved analyzer multilayers for aluminium and boron detection with x-ray fluorescence
    Ricardo, P
    Wiesmann, J
    Nowak, C
    Michaelsen, C
    Bormann, R
    APPLIED OPTICS, 2001, 40 (16) : 2747 - 2754