IR-MALDI ion mobility spectrometry

被引:8
|
作者
Villatoro, Jose [1 ,2 ,3 ]
Zuehlke, Martin [1 ]
Riebe, Daniel [1 ]
Riedel, Jens [2 ]
Beitz, Toralf [1 ]
Loehmannsroeben, Hans-Gerd [1 ]
机构
[1] Univ Potsdam, Phys Chem, Karl Liebknecht Str 24-25, D-14476 Potsdam, Germany
[2] BAM Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany
[3] Humboldt Univ, Sch Analyt Sci Adlershof SALSA, AdlershofUnter Linden 6, D-10099 Berlin, Germany
关键词
Ion mobility spectrometry; IR-MALDI; Laser; ASSISTED-LASER-DESORPTION/IONIZATION; DESORPTION MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; AQUEOUS-SOLUTIONS; NUCLEIC-ACIDS; MATRIX; WATER; BIOMOLECULES; SEPARATION; COMPLEXES;
D O I
10.1007/s00216-016-9739-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The novel combination of infrared matrix-assisted laser dispersion and ionization (IR-MALDI) with ion mobility (IM) spectrometry makes it possible to investigate biomolecules in their natural environment, liquid water. As an alternative to an ESI source, the IR-MALDI source was implemented in an in-house-developed ion mobility (IM) spectrometer. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse (lambda = 2.94 mu m, 6 ns pulse width), which disperses the liquid as nano- and micro-droplets. The prerequisites for the application of IR-MALDI-IM spectrometry as an analytical method are narrow analyte ion signal peaks for a high spectrometer resolution. This can only be achieved by improving the desolvation of ions. One way to full desolvation is to give the cluster ions sufficient time to desolvate. Two methods for achieving this are studied: the implementation of an additional drift tube, as in ESI-IM-spectrometry, and the delayed extraction of the ions. As a result of this optimization procedure, limits of detection between 5 nM and 2.5 mu M as well as linear dynamic ranges of 2-3 orders of magnitude were obtained for a number of substances. The ability of this method to analyze simple mixtures is illustrated by the separation of two different surfactant mixtures.
引用
收藏
页码:6259 / 6268
页数:10
相关论文
共 50 条
  • [21] Ion formation in MALDI mass spectrometry
    Zenobi, R
    Knochenmuss, R
    MASS SPECTROMETRY REVIEWS, 1998, 17 (05) : 337 - 366
  • [22] Ion mobility spectrometry
    Zolotov, Yu.A.
    Journal of Analytical Chemistry, 2006, 61 (06):
  • [23] Spatial Metabolomics of the Human Kidney using MALDI Trapped Ion Mobility Imaging Mass Spectrometry
    Neumann, Elizabeth K.
    Migas, Lukasz G.
    Allen, Jamie L.
    Caprioli, Richard M.
    Van de Plas, Raf
    Spraggins, Jeffrey M.
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 13084 - 13091
  • [24] Ion mobility spectrometry
    Mayer, Thomas
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2014, 17 (3-4) : 103 - 104
  • [25] MALDI coupled to modified traveling wave ion mobility mass spectrometry for fast enantiomeric determination
    Nachtigall, Fabiane M.
    Rojas, Moises
    Santos, Leonardo S.
    JOURNAL OF MASS SPECTROMETRY, 2018, 53 (08): : 693 - 699
  • [26] Ion mobility spectrometry
    Zolotov, Yu A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (06) : 519 - 519
  • [27] Ion mobility spectrometry
    Yu. A. Zolotov
    Journal of Analytical Chemistry, 2006, 61 : 519 - 519
  • [28] Ion mobility spectrometry
    Keller, T
    Binz, R
    Regenscheit, P
    Bernhard, W
    Dirnhofer, R
    Chlewinski, A
    KRIMINALISTIK, 1996, 50 (02): : 137 - 141
  • [29] ION MOBILITY SPECTROMETRY
    HILL, HH
    SIEMS, WF
    STLOUIS, RH
    MCMINN, DG
    ANALYTICAL CHEMISTRY, 1990, 62 (23) : A1201 - A1209
  • [30] Progress in Detection and Structural Characterization of Glycosphingolipids in Crude Lipid Extracts by Enzymatic Phospholipid Disintegration Combined with Thin-Layer Chromatography Immunodetection and IR-MALDI Mass Spectrometry
    Kouzel, Ivan U.
    Pirkl, Alexander
    Pohlentz, Gottfried
    Soltwisch, Jens
    Dreisewerd, Klaus
    Karch, Helge
    Muething, Johannes
    ANALYTICAL CHEMISTRY, 2014, 86 (02) : 1215 - 1222