IR-MALDI ion mobility spectrometry

被引:8
|
作者
Villatoro, Jose [1 ,2 ,3 ]
Zuehlke, Martin [1 ]
Riebe, Daniel [1 ]
Riedel, Jens [2 ]
Beitz, Toralf [1 ]
Loehmannsroeben, Hans-Gerd [1 ]
机构
[1] Univ Potsdam, Phys Chem, Karl Liebknecht Str 24-25, D-14476 Potsdam, Germany
[2] BAM Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany
[3] Humboldt Univ, Sch Analyt Sci Adlershof SALSA, AdlershofUnter Linden 6, D-10099 Berlin, Germany
关键词
Ion mobility spectrometry; IR-MALDI; Laser; ASSISTED-LASER-DESORPTION/IONIZATION; DESORPTION MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; AQUEOUS-SOLUTIONS; NUCLEIC-ACIDS; MATRIX; WATER; BIOMOLECULES; SEPARATION; COMPLEXES;
D O I
10.1007/s00216-016-9739-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The novel combination of infrared matrix-assisted laser dispersion and ionization (IR-MALDI) with ion mobility (IM) spectrometry makes it possible to investigate biomolecules in their natural environment, liquid water. As an alternative to an ESI source, the IR-MALDI source was implemented in an in-house-developed ion mobility (IM) spectrometer. The release of ions directly from an aqueous solution is based on a phase explosion, induced by the absorption of an IR laser pulse (lambda = 2.94 mu m, 6 ns pulse width), which disperses the liquid as nano- and micro-droplets. The prerequisites for the application of IR-MALDI-IM spectrometry as an analytical method are narrow analyte ion signal peaks for a high spectrometer resolution. This can only be achieved by improving the desolvation of ions. One way to full desolvation is to give the cluster ions sufficient time to desolvate. Two methods for achieving this are studied: the implementation of an additional drift tube, as in ESI-IM-spectrometry, and the delayed extraction of the ions. As a result of this optimization procedure, limits of detection between 5 nM and 2.5 mu M as well as linear dynamic ranges of 2-3 orders of magnitude were obtained for a number of substances. The ability of this method to analyze simple mixtures is illustrated by the separation of two different surfactant mixtures.
引用
收藏
页码:6259 / 6268
页数:10
相关论文
共 50 条
  • [1] IR-MALDI ion mobility spectrometry
    José Villatoro
    Martin Zühlke
    Daniel Riebe
    Jens Riedel
    Toralf Beitz
    Hans-Gerd Löhmannsröben
    Analytical and Bioanalytical Chemistry, 2016, 408 : 6259 - 6268
  • [2] IR-MALDI ion mobility spectrometry: physical source characterization and application as HPLC detector
    Villatoro, Jose
    Zuehlke, Martin
    Riebe, Daniel
    Beitz, Toralf
    Weber, Marcus
    Riedel, Jens
    Loehmannsroeben, Hans-Gerd
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2016, 19 (04) : 197 - 207
  • [3] In situ monitoring of photocatalyzed isomerization reactions on a microchip flow reactor by IR-MALDI ion mobility spectrometry
    Chris Prüfert
    Raphael David Urban
    Tillmann Georg Fischer
    José Villatoro
    Daniel Riebe
    Toralf Beitz
    Detlev Belder
    Kirsten Zeitler
    Hans-Gerd Löhmannsröben
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7899 - 7911
  • [4] In situ monitoring of photocatalyzed isomerization reactions on a microchip flow reactor by IR-MALDI ion mobility spectrometry
    Pruefert, Chris
    Urban, Raphael David
    Fischer, Tillmann Georg
    Villatoro, Jose
    Riebe, Daniel
    Beitz, Toralf
    Belder, Detlev
    Zeitler, Kirsten
    Loehmannsroeben, Hans-Gerd
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (28) : 7899 - 7911
  • [5] Sub-ambient pressure IR-MALDI ion mobility spectrometer for the determination of low and high field mobilities
    José Villatoro
    Martin Zühlke
    Daniel Riebe
    Toralf Beitz
    Marcus Weber
    Hans-Gerd Löhmannsröben
    Analytical and Bioanalytical Chemistry, 2020, 412 : 5247 - 5260
  • [6] Sub-ambient pressure IR-MALDI ion mobility spectrometer for the determination of low and high field mobilities
    Villatoro, Jose
    Zuhlke, Martin
    Riebe, Daniel
    Beitz, Toraif
    Weber, Marcus
    Lohmannsroben, Hans-Gerd
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (22) : 5247 - 5260
  • [7] IR-MALDI Mass Spectrometry Imaging with Plasma Post-Ionization of Nonpolar Metabolites
    Schneemann, Julian
    Schaefer, Karl-Christian
    Spengler, Bernhard
    Heiles, Sven
    ANALYTICAL CHEMISTRY, 2022, 94 (46) : 16086 - 16094
  • [8] Liquid phase IR-MALDI and differential mobility analysis of nano- and sub-micron particles
    Pruefert, C.
    Villatoro, J.
    Zuehlke, M.
    Beitz, T.
    Loehmannsroeben, H-G
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2022, 24 (04) : 2275 - 2286
  • [9] IR-MALDI-LDI combined with ion mobility orthogonal time-of-flight mass spectrometry
    Woods, Amina S.
    Ugarov, Michael
    Jackson, Shelley N.
    Egan, Thomas
    Wang, Hay-Yan J.
    Murray, Kermit K.
    Schultz, J. Albert
    JOURNAL OF PROTEOME RESEARCH, 2006, 5 (06) : 1484 - 1487
  • [10] IR-MALDI of low molecular weight compounds using a free electron laser
    Hess, WP
    Park, HK
    Yavas, O
    Haglund, RF
    APPLIED SURFACE SCIENCE, 1998, 127 : 235 - 241