Performance evaluation of a digital intraoral imaging device based on the CMOS photosensor array coupled with an integrated X-ray conversion fiber-optic faceplate

被引:3
|
作者
Cho, Hyosung
Choi, Sungil
Kim, Jongguk
Koo, Yangseo
Kim, Taewoo
Ro, Changjoon
Lee, Bongsoo
Kim, Sin
Kim, Hokyung
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
[2] Myongji Univ, Dept Phys, Yongin 449728, South Korea
[3] Vatech Co Ltd, Radiat Technol Lab, Hwaseong 445811, South Korea
[4] Konkuk Univ, Sch Biomed Engn, Chungju 380701, South Korea
[5] Cheju Natl Univ, Dept Nucl & Energy Engn, Cheju 690756, South Korea
[6] Pusan Natl Univ, Sch Mech Engn, Pusan 609735, South Korea
关键词
Intraoral imaging system; CMOS photosensor; digital radiography; fiber-optic faceplate; image quality;
D O I
10.1016/j.nima.2007.04.071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As a continuation of our digital X-ray imaging sensor R&D, we have developed a cost-effective, intraoral imaging device based on the complementary-metal-oxide semiconductor (CMOS) photosensor array coupled with an integrated X-ray conversion fiber-optic faceplate. It consists of a commercially available CMOS photosensor of a 35 x 35 mu m(2) pixel size and a 688 x 910 pixel array dimension, and a high-efficiency columnar CsI(Tl) scintillator of a 90 mu m thickness directly deposited on a fiber-optic faceplate of a 6 mu m core size and an 1.46 mm thickness with 85/15 core-cladding ratio (NA similar to 1.0 in air). The fiber-optic faceplate is a highly X-ray attenuating material that minimizes X-ray absorption on the end CMOS photosensor array, thus, minimizing X-ray induced noise at the pholosensor array. It uses a high light-output columnar CsI(Tl) scintillator with a peak spectral emission at 545 nm, giving better spatial resolution, but attenuates some of this light due to interfacial and optical attenuation factors. In this paper, we presented the performance analysis of the intraoral imaging device with experimental measurements and acquired X-ray images in terms of modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:330 / 333
页数:4
相关论文
共 12 条
  • [1] Impact of the fiber-optic faceplate on the imaging performance of a CMOS X-ray detector
    Yoo, Seungjun
    Park, Seongbon
    Yun, Seungman
    Kim, Ho Kyung
    Journal of Instrumentation, 2024, 19 (12)
  • [2] Electrical characteristics of intraoral dental imaging devices based on the CMOS imager coupled with integrated X-ray conversion fiber optics
    Cho, Hyosung
    Choi, Sungil
    Lee, Bongsoo
    Kim, Sin
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1147 - +
  • [3] Geometric distortion corrections for fiber-optic tapers in X-ray charge-coupled-device detectors
    Paciorek, W.A.
    Meyer, M.
    Chapuis, G.
    Journal of Applied Crystallography, 1999, 32 (pt 1):
  • [4] Geometric distortion corrections for fiber-optic tapers in X-ray charge-coupled-device detectors
    Paciorek, WA
    Meyer, M
    Chapuis, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1999, 32 : 11 - 14
  • [5] Charge-coupled device fiber optic taper array x-ray detector for protein crystallography
    Naday, I
    Ross, S
    Westbrook, EM
    Zentai, G
    OPTICAL ENGINEERING, 1998, 37 (04) : 1235 - 1244
  • [6] A digital X-ray imaging system based on a CMOS photo-sensor array and its performance tests
    Cho, H
    Kim, S
    Lee, B
    METMBS '05: Proceedings of the 2005 International Conference on Mathematics and Engineering Techniques in Medicine and Biological Sciences, 2005, : 100 - 106
  • [7] Fine adjustable non-glued Fiber Optic Taper array coupled digital X-ray detector
    Zhao, Zhi-Gang
    Wang, Ru
    Lei, Yao-Hu
    Guo, Jin-Chuan
    Yang, Qin-Lao
    Niu, Han-Ben
    Guangzi Xuebao/Acta Photonica Sinica, 2015, 44 (05):
  • [8] Image quality evaluation of a highly-integrated digital X-ray imaging sensor for dental intraoral-imaging applications
    Cho, H. S.
    Choi, S. G.
    Lee, B. S.
    Kim, S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (01) : 30 - 34
  • [9] Implementation of a data acquisition system for 2×2 fiber optic taper array coupled digital X-ray detector
    Zhao, Zhigang
    Wang, Ru
    Huang, Jianheng
    Guo, Jinchuan
    Niu, Hanben
    Open Electrical and Electronic Engineering Journal, 2014, 8 (01): : 152 - 158
  • [10] Fiber-optic taper coupled with a large format charge-coupled device X-ray detector: Fast readout and high duty-cycle ratio
    Ito, Kazuki
    Fujisawa, Tetsuro
    Iwata, Tadahisa
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1160 - +