Fine adjustable non-glued Fiber Optic Taper array coupled digital X-ray detector

被引:0
|
作者
Zhao, Zhi-Gang [1 ]
Wang, Ru [1 ]
Lei, Yao-Hu [1 ]
Guo, Jin-Chuan [1 ]
Yang, Qin-Lao [1 ]
Niu, Han-Ben [1 ]
机构
[1] Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen,518060, China
来源
Guangzi Xuebao/Acta Photonica Sinica | 2015年 / 44卷 / 05期
关键词
Compendex;
D O I
10.3788/gzxb20154405.0504001
中图分类号
学科分类号
摘要
Data acquisition
引用
收藏
相关论文
共 29 条
  • [1] Implementation of a data acquisition system for 2×2 fiber optic taper array coupled digital X-ray detector
    Zhao, Zhigang
    Wang, Ru
    Huang, Jianheng
    Guo, Jinchuan
    Niu, Hanben
    Open Electrical and Electronic Engineering Journal, 2014, 8 (01): : 152 - 158
  • [2] Charge-coupled device fiber optic taper array x-ray detector for protein crystallography
    Naday, I
    Ross, S
    Westbrook, EM
    Zentai, G
    OPTICAL ENGINEERING, 1998, 37 (04) : 1235 - 1244
  • [3] Wafer-scale pixelated scintillator and specially designed data acquisition system for fiber optic taper array-coupled digital x-ray detector
    Zhao, Zhigang
    Li, Ji
    Lei, Yaohu
    Wang, Ru
    Ren, Jianping
    Qiao, Jian
    Niu, Hanben
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 71 - 76
  • [4] Charge-coupled-device/fiberoptic taper array X-ray detector for protein crystallography
    Naday, I
    Ross, S
    Westbrook, EM
    Zentai, G
    SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS, 1997, 3019 : 17 - 34
  • [5] Fiber-optic taper coupled with a large format charge-coupled device X-ray detector: Fast readout and high duty-cycle ratio
    Ito, Kazuki
    Fujisawa, Tetsuro
    Iwata, Tadahisa
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1160 - +
  • [6] Performance evaluation of a digital intraoral imaging device based on the CMOS photosensor array coupled with an integrated X-ray conversion fiber-optic faceplate
    Cho, Hyosung
    Choi, Sungil
    Kim, Jongguk
    Koo, Yangseo
    Kim, Taewoo
    Ro, Changjoon
    Lee, Bongsoo
    Kim, Sin
    Kim, Hokyung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 330 - 333
  • [7] Detective quantum efficiency of a phosphor-coupled photodiode array detector for use in digital X-ray tomosynthesis systems
    Yun, Seungman
    Kim, Seung Ho
    Kim, Dong Woon
    Kim, Ho Kyung
    NDT & E INTERNATIONAL, 2017, 92 : 130 - 135
  • [8] Impact of the fiber-optic faceplate on the imaging performance of a CMOS X-ray detector
    Yoo, Seungjun
    Park, Seongbon
    Yun, Seungman
    Kim, Ho Kyung
    Journal of Instrumentation, 2024, 19 (12)
  • [9] High-resolution X-ray detector based on charge coupled device array
    Ye, Qing
    Guo, Zhiping
    Zheng, Yuhong
    Zhang, Chaozong
    He Jishu/Nuclear Techniques, 2000, 23 (02): : 110 - 115
  • [10] X-ray digital detector array radiology to infer sagging depths in welded assemblies
    Siryabe, Emmanuel
    Juliac, Etienne
    Barthe, Andre
    Ferdinand, Cyrille
    NDT & E INTERNATIONAL, 2020, 111 (111)