Fluoroscopic and gait analysis of the functional performance in stair ascent of two total knee replacement designs

被引:66
|
作者
Fantozzi, S
Benedetti, MG
Leardini, A
Banks, SA
Cappello, A
Assirelli, D
Catani, F
机构
[1] Univ Bologna, Dipartimento Elettron Informat & Sistemist, I-40136 Bologna, Italy
[2] Ist Ortopedici Rizzoli, Movement Anal Lab, I-40136 Bologna, Italy
[3] Biomot Fdn, W Palm Beach, FL 33401 USA
[4] Ist Ortopedici Rizzoli, Dept Orthopaed Surg, I-40136 Bologna, Italy
关键词
total knee replacement; gait analysis; fluoroscopic analysis; stair ascent;
D O I
10.1016/S0966-6362(02)00096-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Understanding total knee replacement mechanics and their influence on patient mobility requires accurate analysis of knee joint kinematics and traditional full body kinematics and kinetics. Three-dimensional fluoroscopic and gait analysis techniques were carried out on patients with either mobile bearing or posterior stabilized knee prostheses during stair ascent. Statistically significant correlation was found between knee flexion at foot strike and the position of the mid-condylar contact points, and between maximum knee adduction moment and corresponding lateral trunk tilt. A more complete and powerful assessment of the functional performances of different TKR designs can be performed in-vivo by combining gait and fluoroscopic analyses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:225 / 234
页数:10
相关论文
共 50 条
  • [31] Kinetic and kinematic gait analysis before and after total knee replacement.
    Perka, C
    Möckel, G
    Boenick, U
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (03): : 191 - 196
  • [32] Non-invasive gait analysis of the patients after total knee replacement
    Sosin, P
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2004, 27 : 177 - 178
  • [33] Performance of stair negotiation in patients with cerebral palsy and stiff knee gait
    Lewerenz, Annika
    Wolf, Sebastian, I
    Dreher, Thomas
    Krautwurst, Britta K.
    GAIT & POSTURE, 2019, 71 : 14 - 19
  • [34] The Effect of Total Knee Replacement on Dual-Task Gait Performance in Older Adults
    Azzam, Ibrahim
    Rozen, Nimrod
    Eliyahu, Amir
    Dabby, Dan
    Elbaz, Avi
    Mor, Amit
    Krasovsky, Tal
    PHYSICAL THERAPY, 2024, 104 (08):
  • [35] Construction-conditioned rollback in total knee replacement: fluoroscopic results
    Wachowski, Martin Michael
    Fiedler, Christoph
    Walde, Tim Alexander
    Balcarek, Peter
    Schuettrumpf, Jan Philipp
    Frosch, Stephan
    Frosch, Karl-Heinz
    Fanghaenel, Jochen
    Gezzi, Riccardo
    Kubein-Meesenburg, Dietmar
    Naegerl, Hans
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2011, 13 (03) : 35 - 42
  • [36] Gait and functional status analysis before and after total knee arthroplasty
    Baczkowicz, Dawid
    Skiba, Grzegorz
    Czerner, Marek
    Majorczyk, Edyta
    KNEE, 2018, 25 (05): : 888 - 896
  • [37] Preoperative Predictors of Persistent Impairments During Stair Ascent and Descent After Total Knee Arthroplasty
    Zeni, Joseph A., Jr.
    Snyder-Mackler, Lynn
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05): : 1130 - 1136
  • [38] Measurement of an intact knee kinematics using gait and fluoroscopic analysis
    Saveh, Amir Hossein
    Katouzian, Hamid Reza
    Chizari, Mahmoud
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (02) : 267 - 272
  • [39] Measurement of an intact knee kinematics using gait and fluoroscopic analysis
    Amir Hossein Saveh
    Hamid Reza Katouzian
    Mahmoud Chizari
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 267 - 272
  • [40] Total knee replacement influences both knee and hip joint kinematics during stair climbing
    Saari, T
    Tranberg, R
    Zügner, R
    Uvehammer, J
    Kärrholm, J
    INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) : 82 - 86