Towards the Identification of Hemodynamic Parameters Involved in Arteriovenous Fistula Maturation and Failure: A Review

被引:13
|
作者
Franzoni, Marco [1 ]
Walsh, Michael T. [1 ]
机构
[1] Univ Limerick, Hlth Res Inst, Bernal Inst, Ctr Appl Biomed Engn Res,Sch Engn, Limerick, Ireland
关键词
Arteriovenous fistula; Wall shear stress; Oscillatory shear index; Hemodynamics index; Temporal wall shear stress gradient; Cone-and-plate; DIALYSIS VASCULAR ACCESS; ATHEROSCLEROSIS-RESISTANT REGIONS; SHEAR-STRESS; ENDOTHELIAL-CELLS; PHENOTYPIC HETEROGENEITY; CAROTID BIFURCATION; DYNAMIC-RESPONSE; DISTURBED FLOW; INSIGHTS; ARTERIAL;
D O I
10.1007/s13239-017-0322-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Native arteriovenous fistulas have a high failure rate mainly due to the lack of maturation and uncontrolled neo-intimal hyperplasia development. Newly established hemodynamics is thought to be central in driving the fistula fate, after surgical creation. To investigate the effects of realistic wall shear stress stimuli on endothelial cells, an in vitro approach is necessary in order to reduce the complexity of the in vivo environment. After a systematic review, realistic WSS waveforms were selected and analysed in terms of magnitude, temporal gradient, presence of reversing phases (oscillatory shear index, OSI) and frequency content (hemodynamics index, HI). The effects induced by these waveforms in cellular cultures were also considered, together with the materials and methods used to cultivate and expose cells to WSS stimuli. The results show a wide heterogeneity of experimental approaches and WSS waveform features that prevent a complete understanding of the mechanisms that regulate mechanotransduction. Furthermore, the hemodynamics derived from the carotid bifurcation is the most investigated (in vitro), while the AVF scenario remains poorly addressed. In conclusion, standardisation of the materials and methods employed, as well as the decomposition of realistic WSS profiles, are required for a better understanding of the hemodynamic effects on AVF outcomes. This standardisation may also lead to a new classification of WSS features according to the risk associated with vascular dysfunction.
引用
收藏
页码:342 / 356
页数:15
相关论文
共 50 条
  • [21] The Transcriptomic Landscape of the Arteriovenous Fistula: The Postoperative Genetic Signature of Maturation Failure
    Vazquez-Padron, Roberto I.
    Rojas, Miguel G.
    Tabbara, Marwan
    Challa, Akshara Sree
    Duque, Juan C.
    Salman, Loay H.
    Martinez, Laisel
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 30 - 30
  • [22] Innate and adaptive immune cells associate with arteriovenous fistula maturation and failure
    Samra, Gunimat
    Rai, Vikrant
    Agrawal, Devendra K.
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2022, 100 (08) : 716 - 727
  • [23] Systemic Profile of Cytokines in Arteriovenous Fistula Patients and Their Associations with Maturation Failure
    Martinez, Laisel
    Perla, Mikael
    Tabbara, Marwan
    Duque, Juan C.
    Rojas, Miguel G.
    Falcon, Nieves Santos
    Pereira-Simon, Simone
    Salman, Loay H.
    Vazquez-Padron, Roberto I.
    KIDNEY360, 2022, 3 (04): : 677 - 686
  • [24] Arteriovenous Fistula Maturation Failure in a Large Cohort of Hemodialysis Patients in the Netherlands
    Voorzaat, Bram M.
    van der Bogt, Koen E. A.
    Janmaat, Cynthia J.
    van Schaik, Jan
    Dekker, Friedo W.
    Rotmans, Joris I.
    WORLD JOURNAL OF SURGERY, 2018, 42 (06) : 1895 - 1903
  • [25] THE IMPACT OF ARTERIOVENOUS FISTULA CREATION ON HEMODYNAMIC PARAMETERS OF RESERVOIR-WAVE ANALYSIS
    Pare, M.
    Fortier, C.
    Mac-Way, F.
    Allard, M.
    Marquis, K.
    Schultz, M.
    Sharman, J.
    Agharazii, M.
    JOURNAL OF HYPERTENSION, 2019, 37 : E209 - E209
  • [26] Surgical and Endovascular Intervention for Dialysis Access Maturation Failure During and After Arteriovenous Fistula Surgery: Review of the Evidence
    Tordoir, Jan H. M.
    Zonnebeld, Niek
    van Loon, Magda M.
    Gallieni, Maurizio
    Hollenbeck, Markus
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 55 (02) : 240 - 248
  • [27] Identification of an arteriovenous fistula in a childCase report and review of the literature
    M. Vassilyadi
    B. Jones
    W. Ball
    Child's Nervous System, 2001, 17 : 685 - 688
  • [28] SERUM LEPTIN, INTIMAL THICKNESS, MEDIAL FIRBOSIS, AND ARTERIOVENOUS FISTULA MATURATION FAILURE
    Kim, Young Su
    Kim, Jwa-Kyung
    Jeon, Yong Deok
    Kim, Hyung Jik
    Kim, Sung Gyun
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [29] Parathyroid Hormone Induces Transition of Myofibroblasts in Arteriovenous Fistula and Increases Maturation Failure
    Liu, Chung-Te
    Hsu, Shih-Chang
    Hsieh, Hui-Ling
    Chen, Cheng-Hsien
    Chen, Chun-You
    Sue, Yuh-Mou
    Lin, Feng-Yen
    Shih, Chun-Ming
    Shiu, Yan-Ting
    Huang, Po-Hsun
    ENDOCRINOLOGY, 2021, 162 (07) : 1 - 15
  • [30] In-silico assessment of arteriovenous fistula maturation with patient-specific computational hemodynamic models
    Ibeas, Jose
    Martinez-Dalmau, Lidia
    Caravaca Rodriguez, Miriam
    Olivares, Andy
    Vallespin, Joaquim
    Soto, Andres
    Galles, Oscar
    Navazo, Diego
    Rubiella, Carolina
    Gonzalez de la Huebra, Teresa
    Correa Soto, Roberto
    Camara, Oscar
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I294 - I295