Treatment of distal radius fractures using a cemented K-wire frame

被引:1
|
作者
Meng, Hongyu [1 ,2 ,3 ]
Xu, Bin [1 ,2 ,3 ]
Xu, Yi [1 ]
Niu, Haiyun [1 ]
Liu, Ning [1 ,2 ,3 ,4 ]
Sun, Donglei [5 ]
机构
[1] Hebei Med Univ, Dept Orthopaed Surg, Hosp 3, Shijiazhuang 050000, Hebei, Peoples R China
[2] Key Lab Biomech Hebei Prov, Shijiazhuang 050000, Hebei, Peoples R China
[3] Orthopaed Res Inst Hebei Prov, Shijiazhuang 050000, Hebei, Peoples R China
[4] Hebei Med Univ, Depi Hand Surg, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
[5] Hebei Med Univ, Cent Lab, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
关键词
Distal radial fracture; Pining; K-wire; EXTERNAL FIXATION;
D O I
10.1186/s12891-022-05550-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This retrospective study included an alternative treatment for types A2, A3, and B1 distal radius fractures using percutaneous fixation with a cemented K-wire frame. Methods From January 2017 to January 2020, 78 patients with distal radius fractures were treated with percutaneous internal fixation using a cemented K-wire frame. There were 47 male patients and 31 female patients. The fractures were classified into types A2 (n = 10), A3 (n = 46), and B1 (n = 22). X-rays were taken immediately after surgery and after the bone had healed. Wrist function was assessed using the Mayo Wrist Score (90-100, excellent; 80-90, good; 60-80, satisfactory; < 60, poor). Patient satisfaction was assessed using the 10-cm visual analog scale. Results Neither fixation failure nor K-wire migration was found (P > 0.05). Osteomyelitis was not observed in this series. All patients achieved bone healing after a mean of 4.5 weeks (range, 4 to 8 weeks). Follow-up lasted a mean of 27 months (range, 24 to 33 months). The mean score of wrist function was 97 (range, 91 to 100). Among them, 66 results were excellent and 12 results were good. The mean patient satisfaction was 10 cm (range, 8 to 10 cm). Conclusions Percutaneous fixation with cemented K-wire frame is a safe and preferred choice for the treatment of types A2, A3, and B1 distal radius fractures. The frame provides support to prevent wire migration. The fixation technique is a minimally invasive procedure that is easy to perform.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Displaced distal radius fractures in children, cast alone vs additional K-wire fixation: a meta-analysis
    Alysia Sengab
    Pieta Krijnen
    Inger Birgitta Schipper
    European Journal of Trauma and Emergency Surgery, 2019, 45 : 1003 - 1011
  • [22] Displaced distal radius fractures in children, cast alone vs additional K-wire fixation: a meta-analysis
    Sengab, Alysia
    Krijnen, Pieta
    Schipper, Inger Birgitta
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2019, 45 (06) : 1003 - 1011
  • [23] Comparison of Miniplate and K-wire in the Treatment of Metacarpal and Phalangeal Fractures
    Ahmed, Zulfiqar
    Haider, Muhammad Imran
    Buzdar, M. Iqbal
    Chugtai, Babar Bakht
    Rashid, Majid
    Hussain, Nazar
    Ali, Farman
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)
  • [24] A Comparison of K-Wire Versus Screw Fixation on the Outcomes of Distal Phalanx Fractures
    Hay, Robyn Aik Siew
    Tay, Shian Chao
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (11): : 2160 - 2167
  • [25] Displaced Distal Radius Fracture in Children, Single vs Double K-Wire Fixation
    Majeed, Farhan
    Ashraf, Maham
    Tahir, Mohsin
    Shams, Ahmad
    Hussain, Mumtaz
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (11): : 3333 - 3336
  • [26] A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
    Mishra, Ratish Kumar
    Sharma, Bhagwati Prasad
    Kumar, Amit
    Sherawat, Rohit
    CHINESE JOURNAL OF TRAUMATOLOGY, 2021, 24 (05) : 301 - 305
  • [27] Radiographic Outcomes following K-Wire Augmentation of Dorsal Spanning Plate Fixation for Intra-Articular Fractures of the Distal Radius
    Shah, Harsh A.
    Martin, Anthony R.
    Geller, Joseph S.
    Iyer, Hariharan
    Dodds, Seth D.
    JOURNAL OF WRIST SURGERY, 2022, 11 (05) : 388 - 394
  • [28] A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
    Mishra Ratish Kumar
    Prasad Sharma Bhagwati
    Kumar Amit
    Sherawat Rohit
    中华创伤杂志英文版, 2021, 24 (05) : 301 - 305
  • [29] History and perspective of K-wire osteosynthesis in the unstable distal radius fracture (colles type)
    Fritz, T
    Wersching, D
    Heyer, T
    Klavora, R
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1996, : 1215 - 1216
  • [30] Volar Locking Plates Versus K-Wire Fixation of Dorsally Displaced Distal Radius Fractures-A Functional Outcome Study
    Hull, Peter
    Baraza, Njalalle
    Gohil, Milesh
    Whalley, Helen
    Mauffrey, Cyril
    Brewster, Mark
    Costa, Matthew L.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (06): : E125 - E128