Influence of Oxygen Diffusion on Thermal Ageing of Cross-Linked Polyethylene Cable Insulation

被引:23
|
作者
Zhang, Yuanyuan [1 ]
Hou, Zongke [1 ]
Wu, Kangning [1 ]
Wang, Shihang [1 ]
Li, Jianying [1 ]
Li, Shengtao [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
关键词
XLPE; thermal ageing; oxygen diffusion; non-uniform; AGED XLPE CABLE; DIELECTRIC BEHAVIOR; OXIDATION; DEGRADATION;
D O I
10.3390/ma13092056
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Thermal ageing of cross-linked polyethylene (XLPE) cable insulation is an important issue threatening the safe operation of power cables. In this paper, thermal ageing of XLPE was carried out at 160 degrees C in air for 240 h. The influence of oxygen diffusion on thermal ageing of XLPE was investigated by Ultraviolet-visible spectrophotometer (UV-Vis), tensile testing, and Fourier transformed infrared spectroscopy (FTIR). It was observed that the degradation degree not only depended on ageing time but also on sample positions. The thermally aged samples were more oxidized in the surface region, presented a darker color, more carbon atoms appeared in the conjugate cluster, had smaller elongation at break and tensile strength, and a larger carbonyl index. As ageing time increased, the non-uniform oxidation of the XLPE samples became more prominent. The degree of non-uniform oxidation caused by oxygen diffusion was quantitatively studied by first order oxidation kinetic. The calculated results demonstrated that carbonyl index measured by FTIR was more sensitive to non-uniform oxidation with a shape parameter in the range of 1-2. The result shown in this paper is helpful for interpreting and predicting the non-uniform ageing behavior of high voltage XLPE cables.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Dynamic ageing research of cross-linked polyethylene cable insulation based on temporal-spatial dimension under combined electro-thermal effect
    Zhao, Yifeng
    Xie, Yue
    Zhao, Yu
    Huang, Jiasheng
    Fan, Xinghui
    Nie, Yangyang
    Liu, Gang
    HIGH VOLTAGE, 2023, 8 (05) : 1067 - 1081
  • [22] Effect of Thermal Ageing on Space Charge Characteristics of Cross-linked Polyethylene
    Xiang, Chenmeng
    Zhou, Quan
    An, Wendou
    Wu, Nengcheng
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [23] CROSS-LINKED POLYETHYLENE INSULATION - CHARACTERIZATION OF VOLATILES
    MEHTA, AA
    HUANG, SJ
    JOHNSON, JF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 32 - PMSE
  • [24] Capacitive Nondestructive Evaluation of Aged Cross-Linked Polyethylene (XLPE) Cable Insulation Material
    Shao, Z. H.
    Bowler, N.
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL DEGRADATION OF MATERIALS IN NUCLEAR POWER SYSTEMS - WATER REACTORS, VOL 2, 2018, : 87 - 97
  • [25] Investigation on dielectric breakdown behavior of thermally aged cross-linked polyethylene cable insulation
    Kim, Chonung
    Jiang, Pingkai
    Liu, Fei
    Hyon, Songchol
    Ri, Myong-guang
    Yu, Yongmyong
    Ho, Myongsong
    POLYMER TESTING, 2019, 80
  • [26] Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation
    Liu, Shuaishuai
    Fifield, Leonard S.
    Bowler, Nicola
    RADIATION PHYSICS AND CHEMISTRY, 2021, 185
  • [27] THE THERMAL-CONDUCTIVITY OF CROSS-LINKED POLYETHYLENE INSULATION IN AERIAL BUNDLED CABLES
    MORGAN, VT
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1991, 26 (06): : 1153 - 1158
  • [28] Electrical treeing behaviours in cross-linked polyethylene cables after thermal ageing
    Zhang, Yi
    Wu, Zaijun
    He, Jiahong
    Zhang, Dongdong
    Hu, Minqiang
    HIGH VOLTAGE, 2023, 8 (04) : 749 - 759
  • [29] Characteristics of Partial Discharge in Cross-linked Polyethylene insulation Cable under Damped AC Voltage
    Zhang, Wei
    Huang, Zhiwei
    Xue, Rong
    Zhang, Long
    Li, Hongjie
    Liu, Chongxin
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1444 - +
  • [30] The investigation of using magnesium hydroxide as a flame retardant in the cable insulation material by cross-linked polyethylene
    Sener, Ahmet Akin
    Demirhan, Enver
    MATERIALS & DESIGN, 2008, 29 (07) : 1376 - 1379