Mitigating the Effects of Electrode Biofouling-Induced Impedance for Improved Long-Term Electrochemical Measurements In Vivo

被引:44
|
作者
Seaton, Blake T. [1 ]
Hill, Daniel F. [2 ]
Cowen, Stephen L. [2 ,3 ]
Heien, Michael L. [1 ]
机构
[1] Univ Arizona, Dept Chem & Biochem, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Physiol, Tucson, AZ USA
[3] Univ Arizona, Evelyn F McKnight Brain Inst, Tucson, AZ USA
关键词
DOPAMINE RELEASE; VOLTAMMETRY; BRAIN; STIMULATION; RESPONSES; RAT; SPECTROSCOPY; DYNAMICS; COCAINE; SIGNALS;
D O I
10.1021/acs.analchem.9b05194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biofouling is a prevalent issue in studies that involve prolonged implantation of electrochemical probes in the brain. In long-term fast-scan cyclic voltammetry (FSCV) studies, biofouling manifests as a shift in the peak oxidative potential of the background signal that worsens over days to weeks, diminishing sensitivity and selectivity to neurotransmitters such as dopamine. Using open circuit potential (OCP) measurements, scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDX), and electrochemical impedance spectroscopy (EIS), we examined the biofouling-induced events that occur due to electrode implantation. We determined that the FSCV background signal shift results from cathodic polarization of the Ag/AgCI-wire reference electrode and increased electrochemical impedance of both the Ag/AgCl-wire reference electrode and carbon-fiber working electrode. These events are likely caused collectively by immune response-induced electrode encapsulation. A head-stage utilizing a three-electrode configuration, designed to compensate for the impedance component of biofouling, reduced the FSCV background signal shift in vivo and preserved dopamine sensitivity at artificially increased impedance levels in vitro. In conjunction with a stable reference electrode, this three-electrode configuration will be critical in achieving reliable neurotransmitter detection for the duration of long-term FSCV studies.
引用
收藏
页码:6334 / 6340
页数:7
相关论文
共 50 条
  • [21] ELECTROCHEMICAL IMPEDANCE OF ORGANIC-COATED STEEL - CORRELATION OF IMPEDANCE PARAMETERS WITH LONG-TERM COATING DETERIORATION
    SCULLY, JR
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (04) : 979 - 990
  • [22] In vivo long-term precision of alveolar process density measurements.
    Southard, T
    Southard, K
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A178 - A178
  • [23] Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo
    Updike, S.J.
    Shults, M.C.
    Rhodes, R.K.
    Gilligan, B.J.
    Luebow, J.O.
    Von Heimburg, D.
    ASAIO Journal, 1994, 40 (02) : 157 - 163
  • [24] LONG-TERM MEASURES OF ELECTRODE IMPEDANCE AND AUDITORY-THRESHOLDS FOR THE INERAID COCHLEAR IMPLANT
    DORMAN, MF
    SMITH, LM
    DANKOWSKI, K
    MCCANDLESS, G
    PARKIN, JL
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1992, 35 (05): : 1126 - 1130
  • [25] An improved acoustic station for deep-sea long-term measurements
    Scappuzzo, Sergio Scire
    Biagi, Simone
    Ameli, Fabrizio
    Caruso, Cinzia
    Cuttone, Giacomo
    D'Aleo, Roberto
    Felice, Fabiano
    Giorgio, Emidio
    Italiano, Francesco
    Lazzaro, Gianluca
    Litrico, Pietro
    Longo, Manfredi
    Meschis, Marco
    Mongelli, Maurizio
    Nicolau, Carlo
    Orlando, Angelo
    Passarello, Santi
    Pulvirenti, Sara
    Sciuto, Davide
    Sgura, Irene
    Traina, Domenico
    2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR THE SEA LEARNING TO MEASURE SEA HEALTH PARAMETERS (METROSEA), 2022, : 506 - 510
  • [26] Long-term monitoring of atmospheric corrosion at weathering steel bridges by an electrochemical impedance method
    Nishikata, Atsushi
    Zhu, Qingjun
    Tada, Eiji
    CORROSION SCIENCE, 2014, 87 : 80 - 88
  • [27] Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
    Prasad, Abhishek
    Sanchez, Justin C.
    JOURNAL OF NEURAL ENGINEERING, 2012, 9 (02)
  • [28] Long-term evaluation of the effect of intracochlear steroid deposition on electrode impedance in cochlear implant patients
    De Ceulaer, G
    Johnson, S
    Yperman, M
    Daemers, K
    Offeciers, FE
    O'Donoghue, GM
    Govaerts, PJ
    OTOLOGY & NEUROTOLOGY, 2003, 24 (05) : 769 - 774
  • [29] Long-term storage of PEGylated liposomal oxaliplatin with improved stability and long circulation times in vivo
    Doi, Yusuke
    Shimizu, Taro
    Ishima, Yu
    Ishida, Tatsuhiro
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 564 : 237 - 243
  • [30] Fabrication of flexible electrode array based on PDMS for long-term in-vivo use
    Jeong, Jinmo
    Chou, Namsun
    Kim, Sohee
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 911 - 914