Mitigating the Effects of Electrode Biofouling-Induced Impedance for Improved Long-Term Electrochemical Measurements In Vivo

被引:44
|
作者
Seaton, Blake T. [1 ]
Hill, Daniel F. [2 ]
Cowen, Stephen L. [2 ,3 ]
Heien, Michael L. [1 ]
机构
[1] Univ Arizona, Dept Chem & Biochem, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Physiol, Tucson, AZ USA
[3] Univ Arizona, Evelyn F McKnight Brain Inst, Tucson, AZ USA
关键词
DOPAMINE RELEASE; VOLTAMMETRY; BRAIN; STIMULATION; RESPONSES; RAT; SPECTROSCOPY; DYNAMICS; COCAINE; SIGNALS;
D O I
10.1021/acs.analchem.9b05194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biofouling is a prevalent issue in studies that involve prolonged implantation of electrochemical probes in the brain. In long-term fast-scan cyclic voltammetry (FSCV) studies, biofouling manifests as a shift in the peak oxidative potential of the background signal that worsens over days to weeks, diminishing sensitivity and selectivity to neurotransmitters such as dopamine. Using open circuit potential (OCP) measurements, scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDX), and electrochemical impedance spectroscopy (EIS), we examined the biofouling-induced events that occur due to electrode implantation. We determined that the FSCV background signal shift results from cathodic polarization of the Ag/AgCI-wire reference electrode and increased electrochemical impedance of both the Ag/AgCl-wire reference electrode and carbon-fiber working electrode. These events are likely caused collectively by immune response-induced electrode encapsulation. A head-stage utilizing a three-electrode configuration, designed to compensate for the impedance component of biofouling, reduced the FSCV background signal shift in vivo and preserved dopamine sensitivity at artificially increased impedance levels in vitro. In conjunction with a stable reference electrode, this three-electrode configuration will be critical in achieving reliable neurotransmitter detection for the duration of long-term FSCV studies.
引用
收藏
页码:6334 / 6340
页数:7
相关论文
共 50 条
  • [1] Long-Term Analysis of In Vivo Characteristics of Recording Electrode Using Electrochemical Impedance Spectroscopy
    Kuwabara, Mariko
    Tashiro, Hiroyuki
    Terasawa, Yasuo
    Nakano, Yukari
    Yoshimura, Yurina
    Osawa, Koji
    Noda, Toshihiko
    Tokuda, Takashi
    Ohta, Jun
    SENSORS AND MATERIALS, 2017, 29 (12) : 1689 - 1702
  • [2] Long-Term Electrode-Skin Impedance Variation for Electromyographic Measurements
    Sousa, Andreia S. P.
    Noites, Andreia
    Vilarinho, Rui
    Santos, Rubim
    SENSORS, 2023, 23 (20)
  • [3] Mitigating long-term effects
    Levett, J
    Gabr, M
    Melkonian, AK
    Mulyadi, B
    Sato, S
    Shoaf, KI
    EARTHQUAKES AND PEOPLE'S HEALTH: VULNERABILITY REDUCTION, PREPAREDNESS AND REHABILITATION, 1997, : 87 - 89
  • [4] A LONG-TERM ELECTRODE SYSTEM FOR ELECTROCARDIOGRAPHY AND IMPEDANCE PNEUMOGRAPHY
    DAY, JL
    LIPPITT, MW
    PSYCHOPHYSIOLOGY, 1964, 1 (02) : 174 - 182
  • [5] Long-Term Measurement of Therapeutic Electrode Impedance in Deep Brain Stimulation
    Sillay, Karl A.
    Chen, Jason C.
    Montgomery, Erwin B., Jr.
    NEUROMODULATION, 2010, 13 (03): : 195 - 200
  • [6] Long-term electrode impedance changes and failure prevalence in cochlear implants
    Newbold, Carrie
    Risi, Frank
    Hollow, Rodney
    Yusof, Yusmeera
    Dowell, Richard
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (07) : 453 - 460
  • [7] Cochlear Implantation: Long-Term Effect of Early Activation on Electrode Impedance
    Alahmadi, Asma
    Abdelsamad, Yassin
    Yousef, Medhat
    Almuhawas, Fida
    Hafez, Ahmed
    Alzhrani, Farid
    Hagr, Abdulrahman
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [8] Effects of Long-Term In vivo Stimulation on the Electrochemical Properties of a Porous Stimulation Electrode for a Suprachoroidal-Transretinal Stimulation (STS) Retinal Prosthesis
    Nomura, Shuhei
    Tashiro, Hiroyuki
    Terasawa, Yasuo
    Nakano, Yukari
    Haruta, Makito
    Sasagawa, Kiyotaka
    Takehara, Hironari
    Morimoto, Takeshi
    Fujikado, Takashi
    Ohta, Jun
    SENSORS AND MATERIALS, 2023, 35 (11) : 3567 - 3584
  • [9] LONG-TERM EFFECTS OF PNEUMONECTOMY ON PULMONARY INPUT IMPEDANCE
    LUCAS, CL
    MURRAY, GF
    WILCOX, BR
    SHALLAL, JA
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1748 - 1748
  • [10] The long-term stability of miniaturized electrochemical sensors for measurements on the environment
    Oelssner, W
    Herrmann, S
    Schwarz, J
    Kaden, H
    CHEMIE INGENIEUR TECHNIK, 2000, 72 (1-2) : 98 - 101