ROI RECONSTRUCTION FROM TRUNCATED CONE-BEAM PROJECTION

被引:4
|
作者
Azencott, Robert [1 ]
Bodmann, Bernhard G. [1 ]
Chowdhury, Tasadduk [1 ]
Labate, Demetrio [1 ]
Sen, Anando [2 ]
Vera, Daniel [3 ]
机构
[1] Univ Houston, Dept Math, Houston, TX 77204 USA
[2] Columbia Univ, Dept Biomed Informat, New York, NY 10032 USA
[3] Inst Tecnol Autonomo Mexico, Matemat, Mexico City 01080, CDMX, Mexico
基金
美国国家科学基金会;
关键词
Cone-beamtransform; interior tomography; region-of-interest tomography; ray transform; regularized reconstruction; IMAGE-RECONSTRUCTION; KATSEVICH ALGORITHM; IMPLEMENTATION; TRANSFORM; FRAMEWORK;
D O I
10.3934/ipi.2018002
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Region-of-Interest (ROI) tomography aims at reconstructing a region of interest C inside a body using only x-ray projections intersecting C and it is useful to reduce overall radiation exposure when only a small specific region of a body needs to be examined. We consider x-ray acquisition from sources located on a smooth curve G in Gamma mathbb R-3 verifying the classical Tuy condition. In this generic situation, the non-trucated cone-beam transform of smooth density functions f admits an explicit inverse Z as originally shown by Grangeat. However Z cannot directly reconstruct f from ROI-truncated projections. To deal with the ROI tomography problem, we introduce a novel reconstruction approach. For densities f in L-infinity(B) where B is a bounded ball in R-3, our method iterates an operator U combining ROI-truncated projections, inversion by the operator Z and appropriate regularization operators. Assuming only knowledge of projections corresponding to a spherical ROI C subset of subset B, given epsilon > 0, we prove that if C is sufficiently large our iterative reconstruction algorithm converges at exponential speed to an epsilon-accurate approximation of f in L-infinity. The accuracy depends on the regularity of f quantified by its Sobolev norm in W-5(B). Our result guarantees the existence of a critical ROI radius ensuring the convergence of our ROI reconstruction algorithm to an epsilon-accurate approximation of f. We have numerically verified these theoretical results using simulated acquisition of ROI-truncated cone-beam projection data for multiple acquisition geometries. Numerical experiments indicate that the critical ROI radius is fairly small with respect to the support region B.
引用
收藏
页码:29 / 57
页数:29
相关论文
共 50 条
  • [21] Projection matrix acquisition for cone-beam computed tomography iterative reconstruction
    Yang, Fuqiang
    Zhang, Dinghua
    Huang, Kuidong
    Shi, Wenlong
    Zhang, Caixin
    Gao, Zongzhao
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [22] Image reconstruction with laterally truncated projections in helical cone-beam CT: Linear prediction based projection completion techniques
    Anoop, K. P.
    Rajgopal, Kasi
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (04) : 283 - 294
  • [23] Cone-beam projection of a deformable volume for motion compensated algebraic reconstruction
    Rit, Simon
    Sarrut, David
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 6544 - +
  • [24] CT projection transform theory for circular cone-beam image reconstruction
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2008, 8 (1264-1267):
  • [25] A reconstruction method for cone-beam computed laminography based on projection transformation
    Sun, Liang
    Zhou, Guangjin
    Qin, Zerui
    Yuan, Songmei
    Lin, Qiang
    Gui, Zhiguo
    Yang, Min
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (04)
  • [26] Local volume reconstruction from width-truncated cone-beam projections by convolution backprojection
    Chen, Zikuan
    OPTICAL ENGINEERING, 2008, 47 (01)
  • [27] Volume-of-Interest Reconstruction from Severely Truncated Data in Dental Cone-Beam CT
    Zhang, Zheng
    Kusnoto, Budi
    Han, Xiao
    Sidky, E. Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [28] Optimization of derivative kernels for exact cone-beam ROI reconstruction in spiral computed tomography
    Lauritsch, G
    Sourbelle, K
    Tam, KC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 728 - 732
  • [29] Optimization of derivative kernels for exact cone-beam ROI reconstruction in Spiral Computed Tomography
    Lauritsch, G
    Sourbelle, K
    Tam, KC
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1652 - 1656
  • [30] An Image Reconstruction Strategy for Truncated Projections of Planar Object in Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    Chen, Siyu
    Cui, Jinxian
    Cong, Dan
    Tian, Ying
    2015 12TH INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (FSKD), 2015, : 1113 - 1117