Cervical pedicle screw fixation at C6 and C7 A cadaveric study

被引:8
|
作者
Li, Ye [1 ]
Liu, Jingchen [1 ]
Liu, Yulong [1 ]
Wu, Yuntao [1 ]
Zhu, Qingsan [1 ]
机构
[1] Jilin Univ, China Japan Union Hosp, Dept Orthopaed Surg, Changchun 130031, Peoples R China
关键词
C6; C7; cervical vertebra; pedicle screw; cadaver; MORPHOMETRIC EVALUATION; PLACEMENT; ACCURACY; MIDDLE; SPINE; VERTEBRAE;
D O I
10.4103/0019-5413.159678
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cervical pedicle screw fixation is an effective method for treating traumatic and non traumatic injuries. But many studies have reported higher incidence of cervical pedicle penetration, so many research efforts have aimed at improving the accuracy of cervical screw fixation. Most of the anatomical studies on cervical pedicle screw placement previously published focused on the measurements of anatomical parameters, the entry point of pedicle screw is vague. We preliminarily designed a C3, C4 and C5 pedicle screw fixation method that had clear entry point and clinical cases confirmed that this method is feasible and safe. So we did this study of cervical pedicle screw fixation for C6 and C7 vertebrae. Materials and Methods: Fifteen cervical vertebrae specimens were prepared and bilateral pedicle screws were manually inserted into C6 and C7. The intersection of the horizontal line through the midpoint of the transverse process root and the vertical line through the intersection of the posterolateral and posterior planes of the isthmus was the entry point. The screws were inserted along the axis of the pedicle, with the screw axis coinciding with the pedicle. The pedicle was truncated axially and sagittally along the trajectory and the narrowest pedicular height (PH), pedicular width (PW), overall length of the screw channel (LSC), transverse angle (E) and vertical angle (F) were measured. Results: In C6, the PW and PH were 6.12+/-0.78 and 7.48+/-0.81 mm, respectively. In C7, the PW and PH were 6.85+/-0.73 and 8.03+/-0.38 mm, respectively. The LSC was 30.83+/-0.91 mm. Two E angles were identified, namely E1 and E2 and their values were 89.61+/-1.24 and 59.71+/-1.10 degrees, respectively. Meanwhile, F averaged 75.86+/-1.12 degrees. Conclusion: The intersection of the horizontal line through the midpoint of the transverse process root and vertical line through the intersection of the posterolateral and posterior planes of the isthmus can be used as an entry point for C6 and C7 pedicle screw fixation. The screws should be inserted at 60 or 90 degrees with the posterolateral isthmus in the horizontal plane and at 75 degrees with the posterior isthmus in the sagittal plane. The LSC should not exceed 30 mm.
引用
收藏
页码:465 / 470
页数:6
相关论文
共 50 条
  • [21] Feasibility and safety report on robotic assistance for cervical pedicle screw fixation: a cadaveric study
    Ryu, Seungjun
    Ha, Byeong-Jin
    Yoon, Sunjin
    Lee, Chang Kyu
    Shin, Dong Ah
    Kim, Keung-Nyun
    Yi, Seong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Congenital Fusion of C6 and C7 Vertebra - A Case Report
    Vanitha
    Teli, Chandrika
    Kadlimatti, H. S.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (08) : AJ1 - AJ2
  • [23] Exploration of sensory impairments associated with C6 and C7 radiculopathies
    Rainville, James
    Laxer, Eric
    Keel, John
    Pena, Enrique
    Kim, David
    Milam, R. Alden
    Carkner, Eric
    SPINE JOURNAL, 2016, 16 (01): : 49 - 54
  • [24] HUMAN C7 POLYMORPHISM - CLASSIFICATION AND ASSOCIATION ANALYSIS WITH C6
    WASHIO, K
    TOKUNAGA, K
    OMOTO, K
    MISAWA, S
    JAPANESE JOURNAL OF HUMAN GENETICS, 1986, 31 (04): : 345 - 352
  • [25] CHARACTERIZATION OF HUMAN-COMPLEMENT COMPONENTS C6 AND C7
    DISCIPIO, RG
    GAGNON, J
    MOLECULAR IMMUNOLOGY, 1982, 19 (11) : 1425 - 1431
  • [26] Interruption of the spinolaminar line at C6 and C7: A normal variant
    Caswell K.L.
    Marx W.F.
    Keats T.E.
    Gehl R.H.
    Emergency Radiology, 2001, 8 (2) : 91 - 93
  • [27] Fracture Dislocation C6 to C7: Importance of Adequate Radiographs
    Munoz-Mahamud, Ernesto
    Combalia, Andres
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2011, 12 (04) : 577 - 578
  • [28] GENETIC-LINKAGE OF C6 AND C7 IN THE COMMON MARMOSET
    WHITEHOUSE, DB
    CYTOGENETICS AND CELL GENETICS, 1984, 37 (1-4): : 606 - 606
  • [29] Assessment of forearm pronation strength in C6 and C7 radiculopathies
    Rainville, James
    Noto, Damon J.
    Jouve, Cristin
    Jenis, Louis
    SPINE, 2007, 32 (01) : 72 - 75
  • [30] GENETIC-POLYMORPHISM OF COMPLEMENT C6 AND HAPLOTYPE ANALYSIS BETWEEN C6 AND C7 IN A JAPANESE POPULATION
    NAKAMURA, S
    OOUE, O
    AKIYAMA, K
    ABE, K
    HUMAN GENETICS, 1984, 68 (02) : 138 - 141